NEXTTEQ NX120 Gas Detection Tube for Carbon Tetrachloride (CCl4), 5-Pack - Gas Detection Tubes For Use In NEXTTEQ NX-1000 Pumps
NEXTTEQGas Detection Tubes For Use In NEXTTEQ NX-1000 Pumps

NEXTTEQ NX120 Gas Detection Tube for Carbon Tetrachloride (CCl4), 5-Pack

The NEXTTEQ NX-1000 Detector Tube (MPN NX120) is a gas detection tube for carbon tetrachloride (CCl4), supplied in a 5-pack for use in NEXTTEQ NX-1000 pumps. It detects CCl4 concentrations from 5 to 60 ppm, enabling…

SKU 3G-OTH-602136

Also listed as: NX 120 · NX-120

Brand
NEXTTEQ
Item
NX120 Gas Detection Tube for Carbon Tetrachloride
Category
Gas Detection Tubes For Use In NEXTTEQ NX-1000 Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

NEXTTEQ
Manufacturer Part Number
NX120
Type
CCl4, Gas Detection Tube, Carbon Tetrachloride ( CCl4 ), 5 PK

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

NEXTTEQ Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The NEXTTEQ NX-1000 Detector Tube (MPN NX120) is a gas detection tube for carbon tetrachloride (CCl4), supplied in a 5-pack for use in NEXTTEQ NX-1000 pumps. It detects CCl4 concentrations from 5 to 60 ppm, enabling precise measurement of this specific gas in industrial environments.

Frequently Asked Questions

What is the NEXTTEQ NX-1000 detector tube used for?

The NEXTTEQ NX-1000 detector tube (MPN NX120) is used to measure carbon tetrachloride (CCl4) concentrations in industrial air. It provides precise readings from 5 to 60 ppm, helping plant engineers and safety teams monitor exposure in chemical processing, manufacturing, and remediation environments.

What are the specifications of the NEXTTEQ NX-1000 CCl4 tube?

The NEXTTEQ NX-120 detector tube detects carbon tetrachloride (CCl4) over a range of 5 to 60 ppm. It is supplied as a 5-pack and is designed for use with NEXTTEQ NX-1000 pumps. The manufacturer part number is NX120.

Where to buy NEXTTEQ NX-1000 detector tubes worldwide?

3G Electric supplies NEXTTEQ NX-1000 detector tubes worldwide. As a global industrial sourcing partner, we handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on the NX120 5-pack for CCl4 detection.

How to use the NEXTTEQ NX-1000 detector tube for CCl4?

Insert the NEXTTEQ NX-120 tube into the NX-1000 pump, break both tips using the built-in tip breaker, then draw the specified sample volume. Read the stain length against the printed scale to determine CCl4 concentration in ppm. Follow the pump manufacturer's instructions for accurate results.

NEXTTEQ Products

3G Electric supplies NEXTTEQ gas detection tubes for use in nextteq nx-1000 pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from NEXTTEQ

View all NEXTTEQ parts
Gas detection tube for measuring methanol (CH3OH) concentrations in air. Designed for use with NEXTTEQ NX-1000 pumps. Detection range: 100 to 1,000 ppmv. Supplied in a 10-pack. Provides direct-reading colorimetric indication
NEXTTEQ
Gas detection tube for measuring methanol (CH3OH) concentrations in air. Designed for use with NEXTTEQ NX-1000 pumps. Detection range: 100 to 1,000 ppmv. Supplied in a 10-pack. Provides direct-reading colorimetric indication
Gas detection tube for use with NEXTTEQ NX-1000 pumps. Detects acetylene (C2H2) and ethylene (C2H4) in two ranges: 20 to 300 ppm and 200 to 2,000 ppm. Features break-off tips. Pack of 5
NEXTTEQ
Gas detection tube for use with NEXTTEQ NX-1000 pumps. Detects acetylene (C2H2) and ethylene (C2H4) in two ranges: 20 to 300 ppm and 200 to 2,000 ppm. Features break-off tips. Pack of 5
Gas detection tube for sulfur dioxide (SO2) measurement in the range of 0.02 to 0.3% vol. Designed for use with NEXTTEQ NX-1000 pumps. Pack of 5 tubes. Suitable for industrial environments where SO2 monitoring is required
NEXTTEQ
Gas detection tube for sulfur dioxide (SO2) measurement in the range of 0.02 to 0.3% vol. Designed for use with NEXTTEQ NX-1000 pumps. Pack of 5 tubes. Suitable for industrial environments where SO2 monitoring is required
Hydrogen sulfide (H2S) gas detection tube for use with NEXTTEQ NX-1000 pumps. Measures H2S concentrations in the range of 0.1 to 1 micron g/mL. Supplied in a pack of 5. Suitable for industrial safety monitoring where H2S may be present
NEXTTEQ
Hydrogen sulfide (H2S) gas detection tube for use with NEXTTEQ NX-1000 pumps. Measures H2S concentrations in the range of 0.1 to 1 micron g/mL. Supplied in a pack of 5. Suitable for industrial safety monitoring where H2S may be present
This 10-pack of carbon monoxide (CO) detection tubes is designed for use with NEXTTEQ NX-1000 pumps. The tubes provide dual measurement ranges of 0.1 to 10% vol and 0.2 to 20% vol for accurate CO concentration readings in industrial environments
NEXTTEQ
This 10-pack of carbon monoxide (CO) detection tubes is designed for use with NEXTTEQ NX-1000 pumps. The tubes provide dual measurement ranges of 0.1 to 10% vol and 0.2 to 20% vol for accurate CO concentration readings in industrial environments
Gas detection tube calibrated for use with NEXTTEQ NX-1000 pumps. Detects dichlorobenzene (P-C6H4CI2) in a range of 10 to 150 ppm. Each pack contains 10 tubes, ready for use in industrial gas monitoring applications such as chemical processing and plant safety
NEXTTEQ
Gas detection tube calibrated for use with NEXTTEQ NX-1000 pumps. Detects dichlorobenzene (P-C6H4CI2) in a range of 10 to 150 ppm. Each pack contains 10 tubes, ready for use in industrial gas monitoring applications such as chemical processing and plant safety
Gas detection tube for measuring xylene (C8H10) concentrations. Designed for use with NEXTTEQ NX-1000 pumps. Supplied in a 10-pack. Each tube provides a single-use measurement for monitoring aromatic hydrocarbon levels in industrial environments
NEXTTEQ
Gas detection tube for measuring xylene (C8H10) concentrations. Designed for use with NEXTTEQ NX-1000 pumps. Supplied in a 10-pack. Each tube provides a single-use measurement for monitoring aromatic hydrocarbon levels in industrial environments
This 10-pack of gas detection tubes is designed for use with NEXTTEQ NX-1000 pumps to measure phosphine (PH3) concentrations. Each tube provides dual measurement ranges of 20 to 700 ppm and 40 to 1400 ppm. Typical applications include industrial hygiene monitoring and leak detection in environments where phosphine may be present
NEXTTEQ
This 10-pack of gas detection tubes is designed for use with NEXTTEQ NX-1000 pumps to measure phosphine (PH3) concentrations. Each tube provides dual measurement ranges of 20 to 700 ppm and 40 to 1400 ppm. Typical applications include industrial hygiene monitoring and leak detection in environments where phosphine may be present