NEXTTEQ Detector Tube: NEXTEQ NX-1000, CH2Cl2, Gas Detection Tube, Dichloromethane ( CH2Cl2) - Gas Detection Tubes For Use In NEXTTEQ NX-1000 Pumps
NEXTTEQGas Detection Tubes For Use In NEXTTEQ NX-1000 Pumps

NEXTTEQ Detector Tube: NEXTEQ NX-1000, CH2Cl2, Gas Detection Tube, Dichloromethane ( CH2Cl2)

The NEXTTEQ NX-1000 Detector Tube (MPN NX138) is a gas detection tube for dichloromethane (CH2Cl2), supplied in a 5-pack for use with NEXTTEQ NX-1000 pumps. It offers dual-range detection: 10 to 200 ppm and 30 to…

SKU 3G-OTH-602249

Also listed as: NX 138 · NX-138

Brand
NEXTTEQ
Item
Detector Tube: NEXTEQ NX-1000, CH2Cl2, Gas Detection Tube, Dichloromethane
Category
Gas Detection Tubes For Use In NEXTTEQ NX-1000 Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

NEXTTEQ
Manufacturer Part Number
NX138
Type
CH2Cl2, Gas Detection Tube, Dichloromethane ( CH2Cl2 ), 5 PK

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

NEXTTEQ Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The NEXTTEQ NX-1000 Detector Tube (MPN NX138) is a gas detection tube for dichloromethane (CH2Cl2), supplied in a 5-pack for use with NEXTTEQ NX-1000 pumps. It offers dual-range detection: 10 to 200 ppm and 30 to 1,000 ppm.

Frequently Asked Questions

What is the NEXTTEQ NX-1000 detector tube used for?

The NEXTTEQ NX-1000 detector tube (MPN NX138) is used to measure dichloromethane (CH2Cl2) concentrations in air. It is designed for use with NEXTTEQ NX-1000 pumps and provides dual-range detection from 10 to 200 ppm and 30 to 1,000 ppm.

What are the specifications of the NEXTTEQ NX-1000 detector tube?

The NEXTTEQ NX-1000 detector tube (MPN NX138) detects dichloromethane (CH2Cl2) with two measurement ranges: 10 to 200 ppm and 30 to 1,000 ppm. It is supplied in a 5-pack and is compatible with NEXTTEQ NX-1000 pumps.

Where to buy NEXTTEQ NX-1000 detector tubes worldwide?

3G Electric supplies NEXTTEQ NX-1000 detector tubes worldwide. As a global industrial solutions provider, we handle logistics, customs, and delivery to your location. Contact us to order the NX138 5-pack for dichloromethane detection.

How to use the NEXTTEQ NX-1000 detector tube?

To use the NEXTTEQ NX-1000 detector tube, break off both tips and insert it into the NX-1000 pump. Follow the pump's operating instructions to draw a sample. Read the concentration directly from the tube's color change scale, matching the appropriate range (10 to 200 ppm or 30 to 1,000 ppm).

NEXTTEQ Products

3G Electric supplies NEXTTEQ gas detection tubes for use in nextteq nx-1000 pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from NEXTTEQ

View all NEXTTEQ parts
Gas detection tube for measuring acetaldehyde (C2H4O) concentrations in air or gas streams. Designed for use with NEXTTEQ NX-1000 pumps, with a detection range of 1 to 30 ppm. Supplied in a 10-pack for field measurement via direct-read color change
NEXTTEQ
Gas detection tube for measuring acetaldehyde (C2H4O) concentrations in air or gas streams. Designed for use with NEXTTEQ NX-1000 pumps, with a detection range of 1 to 30 ppm. Supplied in a 10-pack for field measurement via direct-read color change
Gas detection tube for measuring cyclohexanol (C6H12O) concentrations in air. Designed for use with NEXTTEQ NX-1000 pumps. Detection range: 5 to 500 ppm. Supplied in a 10-pack
NEXTTEQ
Gas detection tube for measuring cyclohexanol (C6H12O) concentrations in air. Designed for use with NEXTTEQ NX-1000 pumps. Detection range: 5 to 500 ppm. Supplied in a 10-pack
Gas detection tube for measuring hydrazine (N2H4) concentrations in air or gas streams. Designed for use with NEXTTEQ NX-1000 pumps. Three measurement ranges: 0.05 to 2.5 ppm, 0.1 to 5 ppm, and 0.2 to 10 ppm. Supplied in a 10-pack
NEXTTEQ
Gas detection tube for measuring hydrazine (N2H4) concentrations in air or gas streams. Designed for use with NEXTTEQ NX-1000 pumps. Three measurement ranges: 0.05 to 2.5 ppm, 0.1 to 5 ppm, and 0.2 to 10 ppm. Supplied in a 10-pack
Phosphine (PH3) gas detection tube for use with NEXTTEQ NX-1000 pumps. Supplied in a 10-pack, it provides three measurement ranges: 0.25 to 5 ppm, 0.5 to 10 ppm, and 1 to 20 ppm. Suitable for industrial environments such as fumigation monitoring and grain storage safety
NEXTTEQ
Phosphine (PH3) gas detection tube for use with NEXTTEQ NX-1000 pumps. Supplied in a 10-pack, it provides three measurement ranges: 0.25 to 5 ppm, 0.5 to 10 ppm, and 1 to 20 ppm. Suitable for industrial environments such as fumigation monitoring and grain storage safety
Gas detection tube for hydrogen sulfide (H2S) used with NEXTTEQ NX-1000 pumps. Dual measurement ranges: 1 to 30 ppm and 2 to 60 ppm. Pack of 10 tubes for industrial air monitoring
NEXTTEQ
Gas detection tube for hydrogen sulfide (H2S) used with NEXTTEQ NX-1000 pumps. Dual measurement ranges: 1 to 30 ppm and 2 to 60 ppm. Pack of 10 tubes for industrial air monitoring
Gas detection tube for butadiene (C4H6) used with NEXTTEQ NX-1000 pumps. Measures concentrations from 0.03 to 2.6% vol. Supplied in a 10-pack for industrial safety monitoring in environments where butadiene may be present
NEXTTEQ
Gas detection tube for butadiene (C4H6) used with NEXTTEQ NX-1000 pumps. Measures concentrations from 0.03 to 2.6% vol. Supplied in a 10-pack for industrial safety monitoring in environments where butadiene may be present
Carbon dioxide (CO2) gas detection tube for use with NEXTTEQ NX-1000 pumps. Measures CO2 concentrations from 0.03 to 0.7% vol (100 to 1,500 ppm). Supplied in a 10-pack. Suitable for industrial hygiene, environmental monitoring, and combustion safety checks
NEXTTEQ
Carbon dioxide (CO2) gas detection tube for use with NEXTTEQ NX-1000 pumps. Measures CO2 concentrations from 0.03 to 0.7% vol (100 to 1,500 ppm). Supplied in a 10-pack. Suitable for industrial hygiene, environmental monitoring, and combustion safety checks
Gas detection tube for sulfur dioxide (SO2) measurement, designed for use with NEXTTEQ NX-1000 pumps. Detects SO2 concentrations from 0.02 to 0.3% vol. Supplied in a pack of 10 tubes. Suitable for industrial safety monitoring in combustion, chemical, and HVAC applications
NEXTTEQ
Gas detection tube for sulfur dioxide (SO2) measurement, designed for use with NEXTTEQ NX-1000 pumps. Detects SO2 concentrations from 0.02 to 0.3% vol. Supplied in a pack of 10 tubes. Suitable for industrial safety monitoring in combustion, chemical, and HVAC applications