NEXTTEQ Detector Tube: NEXTEQ NX-1000, C3H5ClO, Gas Detection Tube, With Pump, 5 to 50 ppm - Gas Detection Tubes For Use In NEXTTEQ NX-1000 Pumps
NEXTTEQGas Detection Tubes For Use In NEXTTEQ NX-1000 Pumps

NEXTTEQ Detector Tube: NEXTEQ NX-1000, C3H5ClO, Gas Detection Tube, With Pump, 5 to 50 ppm

The NEXTTEQ NX-1000 is a gas detection tube for epichlorohydrin (C3H5ClO), designed for use with NEXTTEQ NX-1000 pumps. It measures concentrations from 5 to 50 ppm and is supplied in packs of 5 (MPN NX146).

SKU 3G-OTH-602197

Also listed as: NX 146 · NX-146

Brand
NEXTTEQ
Item
Detector Tube: NEXTEQ NX-1000, C3H5ClO, Gas Detection Tube, With Pump, 5 to 50 ppm
Category
Gas Detection Tubes For Use In NEXTTEQ NX-1000 Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

NEXTTEQ
Manufacturer Part Number
NX146
Type
C3H5ClO, Gas Detection Tube, With Pump, 5 to 50 ppm, 5 PK

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

NEXTTEQ Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The NEXTTEQ NX-1000 is a gas detection tube for epichlorohydrin (C3H5ClO), designed for use with NEXTTEQ NX-1000 pumps. It measures concentrations from 5 to 50 ppm and is supplied in packs of 5 (MPN NX146).

Frequently Asked Questions

What is the NEXTTEQ NX-1000 gas detection tube used for?

The NEXTTEQ NX-1000 tube detects epichlorohydrin (C3H5ClO) in air, measuring concentrations from 5 to 50 ppm. It is used with NEXTTEQ NX-1000 pumps for industrial hygiene, chemical plant safety, and environmental monitoring where epichlorohydrin exposure must be controlled.

What are the specifications of the NEXTTEQ NX-1000 tube?

The NEXTTEQ NX-1000 tube detects epichlorohydrin (C3H5ClO) over a range of 5 to 50 ppm. It is supplied in packs of 5 (MPN NX146) and is designed for use with NEXTTEQ NX-1000 pumps. The tube type is C3H5ClO gas detection with pump.

Where to buy NEXTTEQ NX-1000 gas detection tubes worldwide?

3G Electric supplies NEXTTEQ NX-1000 tubes worldwide, handling logistics, customs, and delivery to your site. As a global industrial solutions provider, we source genuine NEXTTEQ parts like the NX146 pack of 5 tubes for epichlorohydrin detection from 5 to 50 ppm.

How to use the NEXTTEQ NX-1000 tube with a pump?

Break off both tips of the NEXTTEQ NX-1000 tube, insert it into the NEXTTEQ NX-1000 pump inlet, and pull the pump handle fully to draw a sample. Follow the pump stroke count specified for epichlorohydrin (C3H5ClO) at 5 to 50 ppm. Read the concentration directly from the tube scale.

NEXTTEQ Products

3G Electric supplies NEXTTEQ gas detection tubes for use in nextteq nx-1000 pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from NEXTTEQ

View all NEXTTEQ parts
Gas detection tube for measuring acetaldehyde (C2H4O) concentrations in air or gas streams. Designed for use with NEXTTEQ NX-1000 pumps, with a detection range of 1 to 30 ppm. Supplied in a 10-pack for field measurement via direct-read color change
NEXTTEQ
Gas detection tube for measuring acetaldehyde (C2H4O) concentrations in air or gas streams. Designed for use with NEXTTEQ NX-1000 pumps, with a detection range of 1 to 30 ppm. Supplied in a 10-pack for field measurement via direct-read color change
Gas detection tube for measuring cyclohexanol (C6H12O) concentrations in air. Designed for use with NEXTTEQ NX-1000 pumps. Detection range: 5 to 500 ppm. Supplied in a 10-pack
NEXTTEQ
Gas detection tube for measuring cyclohexanol (C6H12O) concentrations in air. Designed for use with NEXTTEQ NX-1000 pumps. Detection range: 5 to 500 ppm. Supplied in a 10-pack
Gas detection tube for measuring hydrazine (N2H4) concentrations in air or gas streams. Designed for use with NEXTTEQ NX-1000 pumps. Three measurement ranges: 0.05 to 2.5 ppm, 0.1 to 5 ppm, and 0.2 to 10 ppm. Supplied in a 10-pack
NEXTTEQ
Gas detection tube for measuring hydrazine (N2H4) concentrations in air or gas streams. Designed for use with NEXTTEQ NX-1000 pumps. Three measurement ranges: 0.05 to 2.5 ppm, 0.1 to 5 ppm, and 0.2 to 10 ppm. Supplied in a 10-pack
Phosphine (PH3) gas detection tube for use with NEXTTEQ NX-1000 pumps. Supplied in a 10-pack, it provides three measurement ranges: 0.25 to 5 ppm, 0.5 to 10 ppm, and 1 to 20 ppm. Suitable for industrial environments such as fumigation monitoring and grain storage safety
NEXTTEQ
Phosphine (PH3) gas detection tube for use with NEXTTEQ NX-1000 pumps. Supplied in a 10-pack, it provides three measurement ranges: 0.25 to 5 ppm, 0.5 to 10 ppm, and 1 to 20 ppm. Suitable for industrial environments such as fumigation monitoring and grain storage safety
Gas detection tube for hydrogen sulfide (H2S) used with NEXTTEQ NX-1000 pumps. Dual measurement ranges: 1 to 30 ppm and 2 to 60 ppm. Pack of 10 tubes for industrial air monitoring
NEXTTEQ
Gas detection tube for hydrogen sulfide (H2S) used with NEXTTEQ NX-1000 pumps. Dual measurement ranges: 1 to 30 ppm and 2 to 60 ppm. Pack of 10 tubes for industrial air monitoring
Gas detection tube for butadiene (C4H6) used with NEXTTEQ NX-1000 pumps. Measures concentrations from 0.03 to 2.6% vol. Supplied in a 10-pack for industrial safety monitoring in environments where butadiene may be present
NEXTTEQ
Gas detection tube for butadiene (C4H6) used with NEXTTEQ NX-1000 pumps. Measures concentrations from 0.03 to 2.6% vol. Supplied in a 10-pack for industrial safety monitoring in environments where butadiene may be present
Carbon dioxide (CO2) gas detection tube for use with NEXTTEQ NX-1000 pumps. Measures CO2 concentrations from 0.03 to 0.7% vol (100 to 1,500 ppm). Supplied in a 10-pack. Suitable for industrial hygiene, environmental monitoring, and combustion safety checks
NEXTTEQ
Carbon dioxide (CO2) gas detection tube for use with NEXTTEQ NX-1000 pumps. Measures CO2 concentrations from 0.03 to 0.7% vol (100 to 1,500 ppm). Supplied in a 10-pack. Suitable for industrial hygiene, environmental monitoring, and combustion safety checks
Gas detection tube for sulfur dioxide (SO2) measurement, designed for use with NEXTTEQ NX-1000 pumps. Detects SO2 concentrations from 0.02 to 0.3% vol. Supplied in a pack of 10 tubes. Suitable for industrial safety monitoring in combustion, chemical, and HVAC applications
NEXTTEQ
Gas detection tube for sulfur dioxide (SO2) measurement, designed for use with NEXTTEQ NX-1000 pumps. Detects SO2 concentrations from 0.02 to 0.3% vol. Supplied in a pack of 10 tubes. Suitable for industrial safety monitoring in combustion, chemical, and HVAC applications