Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

3G Electric
OAKTON Turbidity Meter, 0 to 1000 NTU, 35635-15 - Turbidity Meters
OAKTONTurbidity Meters

OAKTON Turbidity Meter, 0 to 1000 NTU, 35635-15

<p>The OAKTON Turbidity Meter (model 35635-15) is a reliable instrument for measuring turbidity in water and other liquids. With a range of 0 to 1000 NTU and an accuracy of ≤ ±2% of reading, it provides precise…

SKU 3G-OTH-371202

Also listed as: 3563515 · 35635 15

Brand
OAKTON
Item
Turbidity Meter, 0 to 1000 NTU, 35635-15
Part Number
35635-15
Category
Turbidity Meters
Available to Order
Also known as:35635-15OAKTON
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

OAKTON
Manufacturer Part Number
35635-15
Type
≤ +/-2% of Reading Turbidity Accuracy, 35635-15
Range
0 to 1000 NTU
Includes
Carrying Case
Product Type
Turbidity Meter
Turbidity Accuracy
≤ +/-2% of Reading

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

OAKTON Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

<p>The OAKTON Turbidity Meter (model 35635-15) is a reliable instrument for measuring turbidity in water and other liquids. With a range of 0 to 1000 NTU and an accuracy of ≤ ±2% of reading, it provides precise readings for various applications. This meter is suitable for environmental monitoring, water treatment, and industrial quality control.</p><p>As a Singapore-based supplier, 3G Electric offers this OAKTON turbidity meter with convenient SGD quotes on request, GST handling for local buyers, and fast delivery across Singapore and Southeast Asia. Contact us for a quote and experience efficient procurement.</p>

Frequently Asked Questions

What is the measurement range and accuracy of the OAKTON Turbidity Meter 35635-15?

The OAKTON Turbidity Meter 35635-15 has a measurement range of 0 to 1000 NTU and a turbidity accuracy of ≤ ±2% of reading.

Does the OAKTON Turbidity Meter come with a carrying case?

Yes, the OAKTON Turbidity Meter 35635-15 includes a carrying case.

Used in

Common applications for OAKTON
Water quality testing in chemical plants — OAKTON pH electrodes (e.g., 35660-56) for inline or batch pH measurement
Wastewater treatment monitoring — OAKTON dissolved oxygen meters (e.g., 3564300) for DO/BOD analysis in aeration basins
Laboratory calibration — OAKTON ACS-grade pH buffers (e.g., pH 10.01, pH 1.68) for routine meter standardization
Environmental field sampling — OAKTON handheld DO meters for stream or effluent monitoring
HVAC and storage area monitoring — OAKTON analog thermohygrometers (e.g., 3570010) for temperature and humidity logging
Conductivity measurement in process control — OAKTON conductivity probes (e.g., WD-35608-78) for monitoring solution concentration in plating or rinsing baths
Not sure this is the right part? Photo-identify it

OAKTON Products

3G Electric supplies OAKTON turbidity meters. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
OHAUS
OHAUS
Turbidity meter for measuring water clarity in NTU units, with a range of 0 to 1000 NTU, accuracy ≤0.3 NTU, and resolution of 0.1 NTU. Includes two cloths. CE and RoHS compliant. Suitable for monitoring suspended particles in water treatment and process control applications
OHAUS
OHAUS
Turbidity meter with a measurement range of 0 to 1000 NTU, accuracy ≤0.3 NTU, and resolution of 0.1 NTU. CE/RoHS compliant. Used for water clarity testing in laboratory and field applications
OHAUS
OHAUS
Turbidity meter for measuring water clarity in NTU units. Range 0 to 200 NTU, accuracy ≤0.2 NTU, resolution 0.01 NTU. CE and RoHS compliant. Suitable for monitoring suspended particles in water quality applications
OHAUS
OHAUS
Turbidity meter with a measurement range of 0 to 200 NTU, accuracy ≤0.2 NTU, and resolution of 0.01 NTU. Includes four 25 mm vials. CE and RoHS compliant. Used for measuring water clarity in laboratory, environmental, and water treatment applications

More from OAKTON

View all OAKTON parts

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first