We supply parts. EXW Singapore: collect from our office.

Parker CVH161P20 Cartridge Check Valve - Cartridge Check Valves
ParkerCartridge Check Valves

Parker CVH161P20 Cartridge Check Valve

The PARKER Check Valve: Steel (SKU 3G-OTH-203337) is a two-way cartridge check valve with a C16-2 valve cavity size and a pressure rating of 1.5. It has an overall length of 1.5 inches and is constructed from steel…

SKU 3G-OTH-203337

Brand
Parker
Item
CVH161P20 Cartridge Check Valve
Part Number
CVH161P20
Category
Cartridge Check Valves
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Payment
Invoicing in SGD. Bank transfer and corporate PO accepted.

Technical Specifications

Parker
Manufacturer Part Number
CVH161P20
Type
Two-Way, C16-2 Valve Cavity Size, Pressure, CVH161P
Overall Lg
1.5 in

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.
Ask a question

Ask a question

Parker Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The PARKER Check Valve: Steel (SKU 3G-OTH-203337) is a two-way cartridge check valve with a C16-2 valve cavity size and a pressure rating of 1.5. It has an overall length of 1.5 inches and is constructed from steel with a polyurethane seal. The manufacturer part number is CVH161P20.

Frequently Asked Questions

What is the PARKER CVH161P20 check valve used for?

The PARKER CVH161P20 is a two-way cartridge check valve used in hydraulic systems to allow flow in one direction and prevent backflow. It is commonly applied in industrial machinery, mobile equipment, and fluid power circuits where reliable directional control is required.

What are the specifications of the PARKER CVH161P20 check valve?

The PARKER CVH161P20 is a steel two-way cartridge check valve with a C16-2 valve cavity size. It has an overall length of 1.5 inches and a pressure rating of 1.5. The seal material is polyurethane. The manufacturer part number is CVH161P20.

Where to buy the PARKER CVH161P20 check valve worldwide?

You can source the PARKER CVH161P20 check valve worldwide through 3G Electric. As a global industrial equipment distributor, 3G Electric handles full logistics, customs clearance, and delivery to your location. Contact them for availability and lead time.

How to install the PARKER CVH161P20 cartridge check valve?

To install the PARKER CVH161P20, ensure the cavity is clean and free of debris. Insert the valve into the C16-2 cavity and tighten to the manufacturer's recommended torque. Use compatible hydraulic fluid and check for leaks after installation. Always follow Parker's installation guidelines.

Used in

Common applications for Parker
Hydraulic and pneumatic assembly — Parker 41FL-8 brass 45-degree flare nut for 1/2 in OD tubing in SAE J513 circuits
Compressed-air preparation — Parker Series 06E filter/regulator (06E32B18AC) for 1/2 in NPT lines at up to 125 psig
HVAC and refrigeration service — Parker RC01C-series brass quick couplers with safety stop for refrigerant hoses
Refrigerant recovery equipment — Parker 5400-S5-8 steel female quick coupler for automotive and industrial hose systems
Corrosive fluid-power systems — Parker 1/2 GG-SS 316 stainless NPTF-to-NPTF adapter for 1/2-14 female ports
Industrial valve actuation — Parker ZH and ZB series solenoid coils for hydraulic valve bodies at 24 V DC or 110/220 V AC
Not sure this is the right part? Photo-identify it→

Parker Products

3G Electric supplies Parker cartridge check valves. We supply genuine products and their technical documentation.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

Compatible alternatives & equivalents

Cross-referenced by specification & description
Two-way cartridge check valve with steel body and polyurethane seal. Designed for C12-2 cavity size, overall length 1.25 in. Allows flow in one direction and prevents backflow in hydraulic systems
Parker
Two-way cartridge check valve with steel body and polyurethane seal. Designed for C12-2 cavity size, overall length 1.25 in. Allows flow in one direction and prevents backflow in hydraulic systems
Two-way cartridge check valve with steel body, C10-2 cavity size, and polyurethane seal. Overall length of 1 inch. Used in hydraulic systems to prevent reverse flow in fluid power circuits
Parker
Two-way cartridge check valve with steel body, C10-2 cavity size, and polyurethane seal. Overall length of 1 inch. Used in hydraulic systems to prevent reverse flow in fluid power circuits
Steel three-way cartridge check valve for C08-4 cavity size. Allows flow in one direction and prevents backflow in hydraulic systems. Suitable for manifold or block applications in industrial machinery and mobile equipment. Overall length 0.875 in
Parker
Steel three-way cartridge check valve for C08-4 cavity size. Allows flow in one direction and prevents backflow in hydraulic systems. Suitable for manifold or block applications in industrial machinery and mobile equipment. Overall length 0.875 in
Two-way cartridge check valve with steel body and nitrile seal. Designed for C08-2 cavity size, overall length 22 mm. Prevents reverse flow in hydraulic circuits, suitable for manifold mounting in fluid power systems
Parker
Two-way cartridge check valve with steel body and nitrile seal. Designed for C08-2 cavity size, overall length 22 mm. Prevents reverse flow in hydraulic circuits, suitable for manifold mounting in fluid power systems

More from Parker

View all Parker parts →
Block-mounted, two-position, normally closed, one-way pressure cartridge check valve with steel body and polyurethane seal. Allows flow in one direction while blocking reverse flow in hydraulic systems. Suitable for industrial machinery, mobile equipment, and fluid power circuits
Parker
Block-mounted, two-position, normally closed, one-way pressure cartridge check valve with steel body and polyurethane seal. Allows flow in one direction while blocking reverse flow in hydraulic systems. Suitable for industrial machinery, mobile equipment, and fluid power circuits
Block-mounted, two-position, normally closed, one-way pressure cartridge check valve. Constructed of steel with a polyurethane seal. Model C08-2. Used in hydraulic or pneumatic circuits to allow flow in one direction and prevent backflow
Parker
Block-mounted, two-position, normally closed, one-way pressure cartridge check valve. Constructed of steel with a polyurethane seal. Model C08-2. Used in hydraulic or pneumatic circuits to allow flow in one direction and prevent backflow
Two-way cartridge check valve with steel body and polyurethane seal. Designed for C10-2 cavity size, 1 in overall length. Prevents reverse flow in hydraulic circuits, suitable for mobile equipment, machine tools, and fluid power systems
Parker
Two-way cartridge check valve with steel body and polyurethane seal. Designed for C10-2 cavity size, 1 in overall length. Prevents reverse flow in hydraulic circuits, suitable for mobile equipment, machine tools, and fluid power systems
Two-way cartridge check valve with C08-2 cavity size, steel body, polyurethane seal, and 0.875 in overall length. Allows flow in one direction and prevents backflow in hydraulic circuits, lubrication systems, and process equipment
Parker
Two-way cartridge check valve with C08-2 cavity size, steel body, polyurethane seal, and 0.875 in overall length. Allows flow in one direction and prevents backflow in hydraulic circuits, lubrication systems, and process equipment
Two-way cartridge check valve with C08-2 cavity size, constructed of steel with a polyurethane seal. Overall length 0.875 inches. Allows flow in one direction and prevents backflow in hydraulic circuits
Parker
Two-way cartridge check valve with C08-2 cavity size, constructed of steel with a polyurethane seal. Overall length 0.875 inches. Allows flow in one direction and prevents backflow in hydraulic circuits
Two-way cartridge check valve with steel body and nitrile seal. Designed for CAV0W-2 valve cavity. Overall length 0.563 in. Used in hydraulic circuits to permit flow in one direction and prevent backflow, protecting system components
Parker
Two-way cartridge check valve with steel body and nitrile seal. Designed for CAV0W-2 valve cavity. Overall length 0.563 in. Used in hydraulic circuits to permit flow in one direction and prevent backflow, protecting system components
Three-way cartridge check valve with steel body and nitrile seal. Designed for C08-4 cavity size, overall length 0.875 in. Used in hydraulic and pneumatic systems to permit flow in one direction and block reverse flow
Parker
Three-way cartridge check valve with steel body and nitrile seal. Designed for C08-4 cavity size, overall length 0.875 in. Used in hydraulic and pneumatic systems to permit flow in one direction and block reverse flow
Two-way cartridge check valve with C16-2 cavity size, constructed of steel with polyurethane seal. Overall length 1.5 inches. Used in hydraulic systems to permit flow in one direction and block reverse flow
Parker
Two-way cartridge check valve with C16-2 cavity size, constructed of steel with polyurethane seal. Overall length 1.5 inches. Used in hydraulic systems to permit flow in one direction and block reverse flow