RANCO V3-412080-870 Heat Pump Reversing Valve - Heat Pump Reversing Valves
RANCOHeat Pump Reversing Valves

RANCO V3-412080-870 Heat Pump Reversing Valve

The RANCO Heat Pump Reversing Valve (SKU V3-412080-870, MPN V3-412080-870) is a flare-tube type valve rated for 1.3 ton to 3.5 ton systems using R410A refrigerant. It features a 3/4 in suction and 1/2 in discharge…

SKU 3G-OTH-623819

Also listed as: V3412080870 · V3 412080 870

Brand
RANCO
Item
V3-412080-870 Heat Pump Reversing Valve
Category
Heat Pump Reversing Valves
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

RANCO
Manufacturer Part Number
V3-412080-870
Type
Flare Tube
Suction
3/4 in
Discharge
1/2 in

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

RANCO Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The RANCO Heat Pump Reversing Valve (SKU V3-412080-870, MPN V3-412080-870) is a flare-tube type valve rated for 1.3 ton to 3.5 ton systems using R410A refrigerant. It features a 3/4 in suction and 1/2 in discharge connection. 3G Electric interprets your demand for this OEM-specified component, sourcing it across our 14 industrial departments with specialist depth in controls.

Frequently Asked Questions

What is a RANCO heat pump reversing valve used for?

A RANCO heat pump reversing valve directs refrigerant flow to switch between heating and cooling modes. This V3-412080-870 model is designed for 1.3 ton to 3.5 ton R410A systems, with 3/4 in suction and 1/2 in discharge flare connections.

What are the specifications of the RANCO V3-412080-870 reversing valve?

The RANCO V3-412080-870 is a flare-tube reversing valve rated for 1.3 ton to 3.5 ton systems using R410A refrigerant. It has a 3/4 in suction and 1/2 in discharge connection. The manufacturer part number is V3-412080-870.

Where to buy a RANCO heat pump reversing valve worldwide?

3G Electric supplies the RANCO V3-412080-870 reversing valve worldwide. We interpret your demand, source the OEM-specified component, and handle logistics and customs for delivery to your location. Contact us for availability and lead time.

How to install a RANCO reversing valve?

Installation requires brazing the flare connections with proper heat protection to avoid damaging the valve. Ensure the valve is oriented correctly per system flow direction. Always follow the OEM guidelines for R410A systems and use a vacuum pump to remove moisture before charging.

Used in

Common applications for RANCO
Commercial refrigeration — RANCO A12-1506 constant differential defrost control for walk-in freezer defrost cycles
HVAC system protection — RANCO RHS-250150 high-limit pressure switch for overpressure safety in chillers
Industrial cooling — RANCO O12-1506 dual pressure control for monitoring suction and discharge pressures in refrigeration racks
Food storage — RANCO O10-1408 temperature control for maintaining -15°F to 40°F in cold storage rooms
Compressor protection — RANCO P30-3701 mechanical lube oil pressure control for Danfoss compressors in supermarket refrigeration
Refrigerant filtration — RANCO RBFD-163 liquid line filter drier for moisture removal in HCFC systems up to 50 tons

RANCO Products

3G Electric supplies RANCO heat pump reversing valves. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from RANCO

View all RANCO parts
Straight-tube reversing valve for heat pump systems. Suction line size 1 3/8 in. Used in commercial HVAC applications to direct refrigerant flow in systems rated 6.3 ton to 15 ton with R410A refrigerant, suitable for HCFC applications
RANCO
Straight-tube reversing valve for heat pump systems. Suction line size 1 3/8 in. Used in commercial HVAC applications to direct refrigerant flow in systems rated 6.3 ton to 15 ton with R410A refrigerant, suitable for HCFC applications
Straight-tube reversing valve for heat pump systems, designed to direct refrigerant flow for switching between heating and cooling modes. Suitable for R410A systems with a capacity range of 3.8 to 10.1 tons. Features a 7/8 in suction connection. Commonly used in HVAC split systems and packaged units
RANCO
Straight-tube reversing valve for heat pump systems, designed to direct refrigerant flow for switching between heating and cooling modes. Suitable for R410A systems with a capacity range of 3.8 to 10.1 tons. Features a 7/8 in suction connection. Commonly used in HVAC split systems and packaged units
Straight-tube reversing valve for heat pump systems, used to switch refrigerant flow between heating and cooling modes. Rated for R410A systems from 1.7 ton to 0.5 ton, with a 3/8 in suction connection. Compatible with HCFC refrigerants
RANCO
Straight-tube reversing valve for heat pump systems, used to switch refrigerant flow between heating and cooling modes. Rated for R410A systems from 1.7 ton to 0.5 ton, with a 3/8 in suction connection. Compatible with HCFC refrigerants
Straight-tube reversing valve for R410A systems, rated 5.7 ton to 11.7 ton. Features a 1 1/8 in suction connection. Used to direct refrigerant flow for switching heat pumps between heating and cooling modes
RANCO
Straight-tube reversing valve for R410A systems, rated 5.7 ton to 11.7 ton. Features a 1 1/8 in suction connection. Used to direct refrigerant flow for switching heat pumps between heating and cooling modes
Straight-tube reversing valve for heat pump systems, with a 1/2 in suction line. Suitable for R410A and HFC refrigerants, covering a capacity range of 0.5 ton to 1.7 ton. Used to direct refrigerant flow for switching between heating and cooling modes
RANCO
Straight-tube reversing valve for heat pump systems, with a 1/2 in suction line. Suitable for R410A and HFC refrigerants, covering a capacity range of 0.5 ton to 1.7 ton. Used to direct refrigerant flow for switching between heating and cooling modes
Straight-tube reversing valve for heat pump systems, with 1/2 in suction line. Directs refrigerant flow to switch between heating and cooling modes. Suitable for HCFC refrigerants such as R410A
RANCO
Straight-tube reversing valve for heat pump systems, with 1/2 in suction line. Directs refrigerant flow to switch between heating and cooling modes. Suitable for HCFC refrigerants such as R410A
Straight-tube reversing valve for R410A heat pump systems. Rated 5.7 ton to 11.9 ton with a 7/8 in suction connection. Designed for HFC refrigerants in commercial HVAC applications requiring flow reversal between heating and cooling modes
RANCO
Straight-tube reversing valve for R410A heat pump systems. Rated 5.7 ton to 11.9 ton with a 7/8 in suction connection. Designed for HFC refrigerants in commercial HVAC applications requiring flow reversal between heating and cooling modes
Straight-tube reversing valve for heat pump systems, used to switch between heating and cooling modes by directing refrigerant flow. Suction line size is 7/8 in. Suitable for R410A systems in the 1.3 to 6.7 ton range
RANCO
Straight-tube reversing valve for heat pump systems, used to switch between heating and cooling modes by directing refrigerant flow. Suction line size is 7/8 in. Suitable for R410A systems in the 1.3 to 6.7 ton range