Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

REICHERT 13940020 Digital Handheld Refractometer for Sodium - Digital Handheld Refractometers
REICHERTDigital Handheld Refractometers

REICHERT 13940020 Digital Handheld Refractometer for Sodium

The REICHERT Refractometer is a digital handheld instrument for measuring Sodium Chloride Specific Gravity. It features automatic operation with a resolution of 0.0075 and an accuracy of +/-0.002 Sodium Chloride SG.

SKU 3G-OTH-417017

Brand
REICHERT
Item
13940020 Digital Handheld Refractometer for Sodium
Category
Digital Handheld Refractometers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

REICHERT
Manufacturer Part Number
13940020
Type
Specifc Gravity, Auto, Digital

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

REICHERT Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The REICHERT Refractometer is a digital handheld instrument for measuring Sodium Chloride Specific Gravity. It features automatic operation with a resolution of 0.0075 and an accuracy of +/-0.002 Sodium Chloride SG.

Frequently Asked Questions

What is the REICHERT Refractometer used for?

The REICHERT Refractometer measures Sodium Chloride Specific Gravity in industrial fluids. It is used in food processing, chemical manufacturing, and water treatment to verify brine concentration or salt content. Its automatic digital operation provides precise readings for quality control and process monitoring.

What are the specifications of the REICHERT Refractometer?

The REICHERT Refractometer (MPN 13940020) is a digital handheld instrument with automatic operation. It measures Sodium Chloride Specific Gravity with an accuracy of +/-0.002 and a resolution of 0.0075. The device is designed for reliable, repeatable readings in field or lab environments.

Where to buy the REICHERT Refractometer worldwide?

3G Electric supplies the REICHERT Refractometer worldwide. As a global industrial equipment distributor since 1990, we handle full logistics, customs clearance, and delivery to your location. Contact us to source this instrument for your operations.

How to maintain the REICHERT Refractometer?

Clean the prism surface with a soft cloth after each use to prevent residue buildup. Calibrate periodically using distilled water or a certified standard. Store in a dry, protective case. Refer to the REICHERT user manual for detailed maintenance intervals and troubleshooting steps.

Used in

Common applications for REICHERT
Automotive service — REICHERT digital refractometer (model 13940017) for brake fluid boiling point testing
HVAC maintenance — REICHERT analog refractometer (model 137584L0) for ethylene glycol concentration in cooling systems
Food processing — REICHERT digital refractometer (model 13940027) for propylene glycol measurement in food-grade antifreeze
Pharmaceutical lab — REICHERT darkfield colony counter (model 13332700) for microbial colony enumeration
Chemical processing — REICHERT digital refractometer (model 13940024) for ethylene glycol freeze point monitoring
Water treatment — REICHERT digital refractometer (model 13940020) for sodium chloride specific gravity in brine solutions

REICHERT Products

3G Electric supplies REICHERT digital handheld refractometers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
This digital handheld refractometer automatically measures specific gravity in urine samples. It covers a refractive index range of 1 RI to 1.04 RI with an accuracy of +/-0.005 SG (Urine) and a resolution of 0.005 SG (Urine). Suitable for clinical laboratories and medical facilities performing urinalysis
REICHERT
This digital handheld refractometer automatically measures specific gravity in urine samples. It covers a refractive index range of 1 RI to 1.04 RI with an accuracy of +/-0.005 SG (Urine) and a resolution of 0.005 SG (Urine). Suitable for clinical laboratories and medical facilities performing urinalysis
The LAXCO RHD-P-201 is a digital handheld refractometer designed for measuring Sodium Chloride (NaCl) solutions. It features automatic operation with a refractive index range of 1.3330 to 1.4200 nD, accuracy of +/-2%/+/-0.002/0.0003nD, and resolution of 0.0001nD. Suitable for concentration measurement in industrial and laboratory settings
LAXCO
The LAXCO RHD-P-201 is a digital handheld refractometer designed for measuring Sodium Chloride (NaCl) solutions. It features automatic operation with a refractive index range of 1.3330 to 1.4200 nD, accuracy of +/-2%/+/-0.002/0.0003nD, and resolution of 0.0001nD. Suitable for concentration measurement in industrial and laboratory settings
Analog handheld refractometer for measuring serum protein concentration in clinical and laboratory settings. Accuracy ±0.2 g/100 mL, resolution 0.002, with automatic temperature compensation
REICHERT
Analog handheld refractometer for measuring serum protein concentration in clinical and laboratory settings. Accuracy ±0.2 g/100 mL, resolution 0.002, with automatic temperature compensation
This digital handheld refractometer measures refractive index and sodium chloride concentration expressed as specific gravity. It features automatic operation with a refractive index range of 1.333 to 1.42 RI and specific gravity resolution of 0.001 SG with accuracy of ±0.002 SG. Typical applications include food processing, chemical quality control, and industrial fluid analysis
VEE GEE
This digital handheld refractometer measures refractive index and sodium chloride concentration expressed as specific gravity. It features automatic operation with a refractive index range of 1.333 to 1.42 RI and specific gravity resolution of 0.001 SG with accuracy of ±0.002 SG. Typical applications include food processing, chemical quality control, and industrial fluid analysis
This digital handheld refractometer measures propylene glycol concentration with a Brix range of 0% to 95% and accuracy of +/-0.2% PG. It provides +/-0.6°C PG boiling point and freeze point accuracy with a resolution of 0.002. Suitable for quality control in industrial fluid applications
REICHERT
This digital handheld refractometer measures propylene glycol concentration with a Brix range of 0% to 95% and accuracy of +/-0.2% PG. It provides +/-0.6°C PG boiling point and freeze point accuracy with a resolution of 0.002. Suitable for quality control in industrial fluid applications
Analog handheld refractometer for measuring ethylene glycol concentration. Refractive index range 1.333 to 1.402 RI with 0.01 RI resolution and +/-1° F accuracy. Features automatic temperature compensation. Overall dimensions 9 3/4 in depth by 1 1/2 in width. Suitable for checking coolant and antifreeze solutions in industrial fluid maintenance
REICHERT
Analog handheld refractometer for measuring ethylene glycol concentration. Refractive index range 1.333 to 1.402 RI with 0.01 RI resolution and +/-1° F accuracy. Features automatic temperature compensation. Overall dimensions 9 3/4 in depth by 1 1/2 in width. Suitable for checking coolant and antifreeze solutions in industrial fluid maintenance

More from REICHERT

View all REICHERT parts
This digital handheld refractometer measures propylene glycol concentration with accuracy of +/-0.2% PG and +/-1.0°F PG for both freeze and boiling points. It features automatic temperature compensation and a resolution of 0.002. Used in HVAC, refrigeration, and process cooling systems to verify glycol concentration
REICHERT
This digital handheld refractometer measures propylene glycol concentration with accuracy of +/-0.2% PG and +/-1.0°F PG for both freeze and boiling points. It features automatic temperature compensation and a resolution of 0.002. Used in HVAC, refrigeration, and process cooling systems to verify glycol concentration
Digital handheld refractometer for measuring specific gravity of battery acid. Range 1 SG to 1.463 SG with accuracy ±0.003 SG and resolution 0.005. Automatic operation. Overall dimensions: 3 7/8 in depth, 2 1/8 in width, 1 in height
REICHERT
Digital handheld refractometer for measuring specific gravity of battery acid. Range 1 SG to 1.463 SG with accuracy ±0.003 SG and resolution 0.005. Automatic operation. Overall dimensions: 3 7/8 in depth, 2 1/8 in width, 1 in height
This digital handheld refractometer measures refractive index and Brix with automatic operation. It offers a refractive index range of 1.333 to 1.447 RI, resolution of 0.0001 RI, and accuracy of ±0.0002% RI and ±0.2% Brix. Suitable for quality control and process monitoring in industrial liquid applications such as food, beverage, and chemical solutions
REICHERT
This digital handheld refractometer measures refractive index and Brix with automatic operation. It offers a refractive index range of 1.333 to 1.447 RI, resolution of 0.0001 RI, and accuracy of ±0.0002% RI and ±0.2% Brix. Suitable for quality control and process monitoring in industrial liquid applications such as food, beverage, and chemical solutions
This automatic digital handheld refractometer measures glycerin concentration, glycerin boiling point, and glycerin freeze point. It offers a glycerine resolution of 0.2% and a glycerin freeze point accuracy of +/-1°F. Suitable for industrial fluid management and quality control applications requiring precise glycerin parameter monitoring
REICHERT
This automatic digital handheld refractometer measures glycerin concentration, glycerin boiling point, and glycerin freeze point. It offers a glycerine resolution of 0.2% and a glycerin freeze point accuracy of +/-1°F. Suitable for industrial fluid management and quality control applications requiring precise glycerin parameter monitoring
This digital handheld refractometer measures ethylene glycol freeze point with an accuracy of +/-0.2% EG. It features automatic operation, a Brix range of 0% to 95%, and a resolution of 0.002. Suitable for field or lab use in applications requiring glycol concentration measurement
REICHERT
This digital handheld refractometer measures ethylene glycol freeze point with an accuracy of +/-0.2% EG. It features automatic operation, a Brix range of 0% to 95%, and a resolution of 0.002. Suitable for field or lab use in applications requiring glycol concentration measurement
Digital handheld refractometer with automatic operation. Measures engine coolant freeze point and DOT4 brake fluid boiling point. Overall dimensions: 3 7/8 in depth, 2 1/8 in width, 1 in height. Suitable for automotive fluid analysis
REICHERT
Digital handheld refractometer with automatic operation. Measures engine coolant freeze point and DOT4 brake fluid boiling point. Overall dimensions: 3 7/8 in depth, 2 1/8 in width, 1 in height. Suitable for automotive fluid analysis
This digital handheld refractometer is designed for brake fluid analysis, measuring boiling points of DOT3 and DOT4 fluids. It features automatic operation with an accuracy of +/-5.0°F and a resolution of 5.0°F. Suitable for automotive maintenance and quality control applications
REICHERT
This digital handheld refractometer is designed for brake fluid analysis, measuring boiling points of DOT3 and DOT4 fluids. It features automatic operation with an accuracy of +/-5.0°F and a resolution of 5.0°F. Suitable for automotive maintenance and quality control applications
This automatic digital handheld refractometer measures ethanol concentration in windshield wash fluids. It provides refractive index accuracy of ±0.0001 RI and Brix accuracy of ±0.1% with 0.1% Brix resolution. Suitable for quality control in automotive and industrial fluid management
REICHERT
This automatic digital handheld refractometer measures ethanol concentration in windshield wash fluids. It provides refractive index accuracy of ±0.0001 RI and Brix accuracy of ±0.1% with 0.1% Brix resolution. Suitable for quality control in automotive and industrial fluid management