Send a part number, a photo, or a whole BOM — we supply it and stand behind it. EXW Singapore — collect from our office.

3G Electric
Siemens relay lfl - Burner Controls
SiemensBurner Controls

Siemens Relay Lfl

14 sizes & variants — select below · Application: 11 options

Siemens Relay LFL 1.148 is a burner control safety relay for gas, oil, and dual-fuel applications supporting multi-stage or modulating burners. It features UV probe QRA and ionization probe flame monitoring, suitable…

WhatsApp an engineerMessage via Telegram
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.

Common specifications

Siemens
Shared across the range — Application vary by variant (see table below).
type
LFL1.148
fuel types
gas, oil, dual-fuel
burner type
multi-stage or modulating, intermittent operation
power range
medium to large
flame monitoring
UV probe QRA and ionization probe
air damper control
controlled

From the manufacturer's datasheet

Siemens
Safety time for ignition burner
Series 01 and 02 differ in safety time for ignition burner with gas valve for ig
Variant for atmospheric burners
LFL1.638 for high-power atmospheric burners
Operation mode
Intermittent operation (shutdown by controller at least once every 24 h)
Burner configuration
For single or dual tube burners
Flame monitoring options
UV sensor type QRA... and ionization probe
Parallel connection of UV sensors
Possible to connect 2 UV sensors type QRA... in parallel
Grounding requirement
Terminal 22 must be grounded when using QRA...
Reset button force
Manual operation only, force ≤ 10 N
Features
  • For gas, oil, or dual-fuel burners of medium to high power
  • For multi-stage or modulating burners with intermittent operation
  • With controlled air damper
  • Flame monitoring with UV sensor (QRA...) and/or ionization probe
  • Suitable for hot air generators
Typical applications
Control and monitoring of single or dual tube burnersMedium to high power burnersIntermittent operation (shutdown at least once every 24 hours)Multi-stage or modulating burners
Do not open the device or perform any intervention on it.
Do not press the reset button for more than 10 seconds, as prolonged unlocking destroys the blocking relay.
Select a size

Showing 14 / 14 variants — scroll the table for more

Part No (MPN)—3G SKU3G-CBM-05815Application—
Part No (MPN)—3G SKU3G-CBM-05816Applicationgas, oil or dual-fuel burners
Part No (MPN)—3G SKU3G-CBM-05817ApplicationMulti-stage or modulating burners
Part No (MPN)—3G SKU3G-CBM-05818ApplicationGas, oil, or dual-fuel burner control
Part No (MPN)—3G SKU3G-CBM-05819Applicationmedium to high power gas/oil/dual fuel burners
Part No (MPN)—3G SKU3G-CBM-05820Applicationgas, oil or dual-fuel burners
Part No (MPN)—3G SKU3G-CBM-05821Applicationgas/oil/dual-fuel burner control
Part No (MPN)—3G SKU3G-CBM-05822Applicationgas, oil or dual-fuel burners medium to high power
Part No (MPN)—3G SKU3G-CBM-05823Application—
Part No (MPN)—3G SKU3G-CBM-05824Applicationburner control safety relay
Part No (MPN)—3G SKU3G-CBM-05825ApplicationGas, oil, or dual-fuel burners
Part No (MPN)—3G SKU3G-CBM-05826Applicationatmospheric burners high power
Part No (MPN)—3G SKU3G-CBM-05827ApplicationMedium to large power burners with modulating or staged operation
Part No (MPN)—3G SKU3G-CBM-05839ApplicationGas, oil or dual-fuel burners, medium to large power
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Frequently Asked Questions

What is the difference between series 01 and 02?

They differ in the safety time for the ignition burner with gas valve for ignition gas.

Can two UV sensors be connected?

Yes, two UV sensors of type QRA... can be connected in parallel.

What is the requirement for the reset button?

It must be operated manually with a force ≤ 10 N, without tools or sharp objects.

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first

Siemens Products

3G Electric supplies Siemens burner controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves →Ignition Transformers →Burner Controls →Spare Parts →All Products →

More from Siemens

View all Siemens parts →
Cell QRA 2M
Siemens
Cell QRA 2M
Siemens
Siemens
Mounting for QRB1 (A)
Siemens
Siemens
Flange for QRB1 (A)
Relay LMO 64 301.C2
Siemens
Relay LMO 64 301.C2
Quartz AGG 03
Siemens
Quartz AGG 03
Siemens
Siemens
Base LFS 1
Relay LMO 24 111.C2
Siemens
Relay LMO 24 111.C2
Cell QRB1A-A068B70B
Siemens
Cell QRB1A-A068B70B