Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

SCHNEIDER Definite Purpose Contactor: 3 Poles, 120V AC, 75 A - Non-Reversing Definite Purpose Contactors
SCHNEIDERNon-Reversing Definite Purpose Contactors

SCHNEIDER Definite Purpose Contactor: 3 Poles, 120V AC, 75 A

The SCHNEIDER 8910 Series Type DPA Definite Purpose Contactor is a three-pole, non-reversing contactor with a 75 A rating and a coil voltage of 110/120V AC. Designed for HVACR applications, it features a 3NO main…

SKU 3G-OTH-43472

Brand
SCHNEIDER
Item
Definite Purpose Contactor: 3 Poles, 120V AC, 75 A
Category
Non-Reversing Definite Purpose Contactors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

SCHNEIDER
Manufacturer Part Number
8910DPA73RV02
Series
8910 Series Type DPA
Phase
Three
Coil Voltage
110/120V AC
Contactor Style
HVACR Definite Purpose Contactor
Main Pole Contact Form
3NO
Maximum Voltage Rating
600V AC
Terminal Connection Type
Quick-Disconnect Terminals
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

SCHNEIDER Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The SCHNEIDER 8910 Series Type DPA Definite Purpose Contactor is a three-pole, non-reversing contactor with a 75 A rating and a coil voltage of 110/120V AC. Designed for HVACR applications, it features a 3NO main pole contact form, a maximum voltage rating of 600V AC, and quick-disconnect terminals. This SCHNEIDER contactor is part of the 8910 Series Type DPA and is suitable for three-phase systems.

Frequently Asked Questions

What is the SCHNEIDER 8910DPA73RV02 definite purpose contactor used for?

The SCHNEIDER 8910DPA73RV02 is a three-pole, non-reversing definite purpose contactor designed for HVACR applications such as air conditioning, refrigeration, and heating systems. It switches power to compressors, fans, and pumps in three-phase equipment, with a 75 A rating and 600V AC maximum voltage.

What are the specifications of the SCHNEIDER 8910DPA73RV02 contactor?

This SCHNEIDER contactor has a coil voltage of 110/120V AC, a 75 A current rating, and a maximum voltage rating of 600V AC. It features three normally open (3NO) main poles, quick-disconnect terminals, and is part of the 8910 Series Type DPA for three-phase HVACR systems.

Where to buy the SCHNEIDER 8910DPA73RV02 contactor worldwide?

3G Electric supplies the SCHNEIDER 8910DPA73RV02 definite purpose contactor worldwide. As a global industrial equipment distributor since 1990, we handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time.

How to install the SCHNEIDER 8910DPA73RV02 definite purpose contactor?

To install the SCHNEIDER 8910DPA73RV02, ensure power is off, mount the contactor securely, and connect the three-phase power lines to the line-side terminals and the load to the load-side terminals. Wire the 110/120V AC coil to the control circuit. Use quick-disconnect terminals per the wiring diagram.

Used in

Common applications for SCHNEIDER
Motor starting in conveyor systems — Schneider Altistart ATS 22 soft starters (e.g., ATS22D17S6U) reduce inrush current.
Speed control for industrial pumps — Schneider Altivar ATV320 VFDs (e.g., ATV320U55N4W) provide variable flow regulation.
Machine safety interlocking — Schneider XPSUAF13AP safety relays monitor emergency stop circuits on assembly lines.
Panel-mounted control stations — Schneider XB5 flush push buttons (ZB5AA5) serve as start/stop operators in MCCs.
Heavy-duty motor switching — Schneider LC1G150LSEA contactors handle 150 A loads in compressor and crusher applications.
Emergency stop actuation — Schneider 9001K mushroom-head push buttons (9001KR25R) provide red, momentary stop functions.

SCHNEIDER Products

3G Electric supplies SCHNEIDER non-reversing definite purpose contactors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Similar products

Matched by specification & description
SCHNEIDER Contactor: 3 Poles, 3NO Contacts, 185 A, 120V AC/48V AC Coil (MPN LC1G185EHEA). Key specifications — Brand: SCHNEIDER; Integrated Surge Suppression: No; Wire Termination Type: Spring Loaded; Nominal Coil Voltage @ 60Hz: 48V AC.
SCHNEIDER
SCHNEIDER Contactor: 3 Poles, 3NO Contacts, 185 A, 120V AC/48V AC Coil (MPN LC1G185EHEA). Key specifications — Brand: SCHNEIDER; Integrated Surge Suppression: No; Wire Termination Type: Spring Loaded; Nominal Coil Voltage @ 60Hz: 48V AC.
SCHNEIDER ELECTRIC IEC Contactor: Non-Reversing, 3 Poles, 3NO Contacts, 150 A, 120V AC/48V AC Coil (MPN LC1D150A6EHE). Key specifications — Brand: SCHNEIDER; Integrated Surge Suppression: Yes; Nominal Coil Voltage @ 60Hz: 48V AC.
SCHNEIDER
SCHNEIDER ELECTRIC IEC Contactor: Non-Reversing, 3 Poles, 3NO Contacts, 150 A, 120V AC/48V AC Coil (MPN LC1D150A6EHE). Key specifications — Brand: SCHNEIDER; Integrated Surge Suppression: Yes; Nominal Coil Voltage @ 60Hz: 48V AC.
SCHNEIDER ELECTRIC IEC Contactor: Reversing, 3 Poles, 3NO Contacts, 66 A, 120V AC/48V AC Coil (MPN LC2D80AEHE). Key specifications — Brand: SCHNEIDER; Integrated Surge Suppression: Yes; Nominal Coil Voltage @ 60Hz: 48V AC.
SCHNEIDER
SCHNEIDER ELECTRIC IEC Contactor: Reversing, 3 Poles, 3NO Contacts, 66 A, 120V AC/48V AC Coil (MPN LC2D80AEHE). Key specifications — Brand: SCHNEIDER; Integrated Surge Suppression: Yes; Nominal Coil Voltage @ 60Hz: 48V AC.
SCHNEIDER Contactor: 4 Poles, 4NO Contacts, 265 A, 120V AC/48V AC Coil (MPN LC1G2654EHEN). Key specifications — Brand: SCHNEIDER; Integrated Surge Suppression: No; Wire Termination Type: Spring Loaded; Nominal Coil Voltage @ 60Hz: 48V AC.
SCHNEIDER
SCHNEIDER Contactor: 4 Poles, 4NO Contacts, 265 A, 120V AC/48V AC Coil (MPN LC1G2654EHEN). Key specifications — Brand: SCHNEIDER; Integrated Surge Suppression: No; Wire Termination Type: Spring Loaded; Nominal Coil Voltage @ 60Hz: 48V AC.
SCHNEIDER Contactor: 3 Poles, 3NO Contacts, 185 A, 24V AC/48V AC Coil (MPN LC1G185BEEA). Key specifications — Brand: SCHNEIDER; Integrated Surge Suppression: No; Wire Termination Type: Spring Loaded; Nominal Coil Voltage @ 60Hz: 48V AC.
SCHNEIDER
SCHNEIDER Contactor: 3 Poles, 3NO Contacts, 185 A, 24V AC/48V AC Coil (MPN LC1G185BEEA). Key specifications — Brand: SCHNEIDER; Integrated Surge Suppression: No; Wire Termination Type: Spring Loaded; Nominal Coil Voltage @ 60Hz: 48V AC.
SCHNEIDER Contactor: 4 Poles, 4NO Contacts, 185 A, 120V AC/48V AC Coil (MPN LC1G1854EHEA). Key specifications — Brand: SCHNEIDER; Integrated Surge Suppression: No; Wire Termination Type: Spring Loaded; Nominal Coil Voltage @ 60Hz: 48V AC.
SCHNEIDER
SCHNEIDER Contactor: 4 Poles, 4NO Contacts, 185 A, 120V AC/48V AC Coil (MPN LC1G1854EHEA). Key specifications — Brand: SCHNEIDER; Integrated Surge Suppression: No; Wire Termination Type: Spring Loaded; Nominal Coil Voltage @ 60Hz: 48V AC.

More from SCHNEIDER

View all SCHNEIDER parts