Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

SCHNEIDER Soft Start: 200-240V AC, 6 A Output Current, With Bypass, IP00/NEMA 1 - Schneider Altistart ATS 01
SCHNEIDERSchneider Altistart ATS 01

SCHNEIDER Soft Start: 200-240V AC, 6 A Output Current, With Bypass, IP00/NEMA 1

The Schneider Altistart ATS 01 is a soft start with bypass, rated for 200-240V AC and 6 A output current, with a control voltage of 110-240V AC. It is configured as IP00/NEMA 1 and supports 60/50 Hz operation (MPN…

SKU 3G-OTH-55376

Brand
SCHNEIDER
Item
Soft Start: 200-240V AC, 6 A Output Current, With Bypass, IP00/NEMA 1
Category
Schneider Altistart ATS 01
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

SCHNEIDER
Manufacturer Part Number
ATS01N206LU
Type
With Bypass, IP00/NEMA 1, 60/50 Hz
Output Current
6 A
Control Voltage
110-240V AC

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

SCHNEIDER Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Schneider Altistart ATS 01 is a soft start with bypass, rated for 200-240V AC and 6 A output current, with a control voltage of 110-240V AC. It is configured as IP00/NEMA 1 and supports 60/50 Hz operation (MPN ATS01N206LU).

Frequently Asked Questions

What is the Schneider ATS01N206LU soft start used for?

The Schneider ATS01N206LU soft start is used to control motor acceleration and deceleration in industrial applications, reducing mechanical stress and electrical surges. It is suitable for pumps, fans, compressors, and conveyors operating at 200-240V AC with a 6 A output current.

What are the specifications of the Schneider ATS01N206LU?

The Schneider ATS01N206LU is an Altistart ATS 01 soft start with bypass, rated IP00/NEMA 1. It operates at 200-240V AC, 60/50 Hz, with a 6 A output current and a control voltage of 110-240V AC. The manufacturer part number is ATS01N206LU.

Where to buy the Schneider ATS01N206LU worldwide?

You can source the Schneider ATS01N206LU soft start through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide locations, ensuring the product reaches your facility reliably.

How to install the Schneider ATS01N206LU soft start?

Install the Schneider ATS01N206LU on a flat, vertical surface within its IP00/NEMA 1 enclosure. Connect the 200-240V AC supply to the input terminals and the motor to the output. Set the control voltage to 110-240V AC. Follow standard electrical safety practices and consult the manual for bypass configuration.

Used in

Common applications for SCHNEIDER
Motor starting in conveyor systems — Schneider Altistart ATS 22 soft starters (e.g., ATS22D17S6U) reduce inrush current.
Speed control for industrial pumps — Schneider Altivar ATV320 VFDs (e.g., ATV320U55N4W) provide variable flow regulation.
Machine safety interlocking — Schneider XPSUAF13AP safety relays monitor emergency stop circuits on assembly lines.
Panel-mounted control stations — Schneider XB5 flush push buttons (ZB5AA5) serve as start/stop operators in MCCs.
Heavy-duty motor switching — Schneider LC1G150LSEA contactors handle 150 A loads in compressor and crusher applications.
Emergency stop actuation — Schneider 9001K mushroom-head push buttons (9001KR25R) provide red, momentary stop functions.

SCHNEIDER Products

3G Electric supplies SCHNEIDER schneider altistart ats 01. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
SCHNEIDER Soft Start: 200-240V AC, 9 A Output Current, With Bypass, IP00/NEMA 1, 60/50 Hz (MPN ATS01N209LU)
SCHNEIDER
SCHNEIDER Soft Start: 200-240V AC, 9 A Output Current, With Bypass, IP00/NEMA 1, 60/50 Hz (MPN ATS01N209LU)
SCHNEIDER Soft Start: 200-240V AC, 12 A Output Current, With Bypass, IP00/NEMA 1, 60/50 Hz (MPN ATS01N212LU)
SCHNEIDER
SCHNEIDER Soft Start: 200-240V AC, 12 A Output Current, With Bypass, IP00/NEMA 1, 60/50 Hz (MPN ATS01N212LU)
SCHNEIDER Soft Start: 110-480V AC, 3 A Output Current, With Bypass, IP20/NEMA 1, 60/50 Hz (MPN ATS01N103FT)
SCHNEIDER
SCHNEIDER Soft Start: 110-480V AC, 3 A Output Current, With Bypass, IP20/NEMA 1, 60/50 Hz (MPN ATS01N103FT)
SCHNEIDER Soft Start: 110-480V AC, 9 A Output Current, With Bypass, IP20/NEMA 1, 60/50 Hz (MPN ATS01N109FT)
SCHNEIDER
SCHNEIDER Soft Start: 110-480V AC, 9 A Output Current, With Bypass, IP20/NEMA 1, 60/50 Hz (MPN ATS01N109FT)
SCHNEIDER Soft Start: 110-480V AC, 6 A Output Current, With Bypass, IP20/NEMA 1, 60/50 Hz (MPN ATS01N106FT)
SCHNEIDER
SCHNEIDER Soft Start: 110-480V AC, 6 A Output Current, With Bypass, IP20/NEMA 1, 60/50 Hz (MPN ATS01N106FT)
SCHNEIDER Soft Start: 380-415V AC, 32 A Output Current, With Bypass, IP20, 60/50 Hz, Three Phase (MPN ATS01N232QN)
SCHNEIDER
SCHNEIDER Soft Start: 380-415V AC, 32 A Output Current, With Bypass, IP20, 60/50 Hz, Three Phase (MPN ATS01N232QN)

More from SCHNEIDER

View all SCHNEIDER parts
SCHNEIDER Soft Start: 460-480V AC, 12 A Output Current, With Bypass, IP20/NEMA 1, 60/50 Hz, 24V DC (MPN ATS01N212RT)
SCHNEIDER
SCHNEIDER Soft Start: 460-480V AC, 12 A Output Current, With Bypass, IP20/NEMA 1, 60/50 Hz, 24V DC (MPN ATS01N212RT)
SCHNEIDER Soft Start: 460-480V AC, 22 A Output Current, With Bypass, IP20/NEMA 1, 60/50 Hz, 24V DC (MPN ATS01N222RT)
SCHNEIDER
SCHNEIDER Soft Start: 460-480V AC, 22 A Output Current, With Bypass, IP20/NEMA 1, 60/50 Hz, 24V DC (MPN ATS01N222RT)
SCHNEIDER Soft Start: 380-415V AC, 6 A Output Current, With Bypass, IP20, 60/50 Hz, Three Phase (MPN ATS01N206QN)
SCHNEIDER
SCHNEIDER Soft Start: 380-415V AC, 6 A Output Current, With Bypass, IP20, 60/50 Hz, Three Phase (MPN ATS01N206QN)
SCHNEIDER Soft Start: 460-480V AC, 32 A Output Current, With Bypass, IP20/NEMA 1, 60/50 Hz, 24V DC (MPN ATS01N232RT)
SCHNEIDER
SCHNEIDER Soft Start: 460-480V AC, 32 A Output Current, With Bypass, IP20/NEMA 1, 60/50 Hz, 24V DC (MPN ATS01N232RT)
SCHNEIDER Soft Start: 200-240V AC, 25 A Output Current, With Bypass, IP20, 60/50 Hz, Single Phase (MPN ATS01N125FT)
SCHNEIDER
SCHNEIDER Soft Start: 200-240V AC, 25 A Output Current, With Bypass, IP20, 60/50 Hz, Single Phase (MPN ATS01N125FT)
SCHNEIDER Soft Start: 380-415V AC, 12 A Output Current, With Bypass, IP20, 60/50 Hz, Three Phase (MPN ATS01N212QN)
SCHNEIDER
SCHNEIDER Soft Start: 380-415V AC, 12 A Output Current, With Bypass, IP20, 60/50 Hz, Three Phase (MPN ATS01N212QN)
SCHNEIDER Soft Start: 200-240V AC, 22 A Output Current, With Bypass, IP20/NEMA 1, 60/50 Hz, 24V DC (MPN ATS01N222LU)
SCHNEIDER
SCHNEIDER Soft Start: 200-240V AC, 22 A Output Current, With Bypass, IP20/NEMA 1, 60/50 Hz, 24V DC (MPN ATS01N222LU)
SCHNEIDER Soft Start: 460-480V AC, 9 A Output Current, With Bypass, IP20/NEMA 1, 60/50 Hz, 24V DC (MPN ATS01N209RT)
SCHNEIDER
SCHNEIDER Soft Start: 460-480V AC, 9 A Output Current, With Bypass, IP20/NEMA 1, 60/50 Hz, 24V DC (MPN ATS01N209RT)