Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

SCHNEIDER Contactor: Non-Reversing, 4 Poles, 4NO Contacts, 200 A - Non-Reversing IEC Contactors
SCHNEIDERNon-Reversing IEC Contactors

SCHNEIDER Contactor: Non-Reversing, 4 Poles, 4NO Contacts, 200 A

The SCHNEIDER ELECTRIC IEC Contactor is a non-reversing contactor with 4 poles and 4 normally open contacts, rated at 200 A. It features a nominal coil voltage of 48V AC at 60Hz and includes integrated surge…

SKU 3G-OTH-48450

Brand
SCHNEIDER
Item
Contactor: Non-Reversing, 4 Poles, 4NO Contacts, 200 A
Category
Non-Reversing IEC Contactors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

SCHNEIDER
Manufacturer Part Number
LC1DT200A6BNE
Type
200 A
Poles
4
Contacts
4NO
AC/48V AC Coil
24V
Nominal Coil Voltage @ 60Hz
48V AC
Integrated Surge Suppression
Yes

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

SCHNEIDER Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The SCHNEIDER ELECTRIC IEC Contactor is a non-reversing contactor with 4 poles and 4 normally open contacts, rated at 200 A. It features a nominal coil voltage of 48V AC at 60Hz and includes integrated surge suppression. This product is identified by manufacturer part number LC1DT200A6BNE.

Frequently Asked Questions

What is the SCHNEIDER ELECTRIC IEC Contactor LC1DT200A6BNE used for?

This non-reversing contactor is used for switching and controlling power in industrial motor control, lighting, and heating applications. With 4 normally open contacts rated at 200 A and a 48V AC coil, it is suitable for high-current circuits requiring reliable on/off control.

What are the specifications of the SCHNEIDER LC1DT200A6BNE contactor?

The SCHNEIDER LC1DT200A6BNE is a 4-pole, non-reversing IEC contactor with 4NO contacts rated at 200 A. It has a nominal coil voltage of 48V AC at 60Hz and includes integrated surge suppression. The manufacturer part number is LC1DT200A6BNE.

Where to buy the SCHNEIDER LC1DT200A6BNE contactor worldwide?

3G Electric supplies the SCHNEIDER LC1DT200A6BNE contactor to customers worldwide. As a global industrial solutions provider, we handle full logistics and customs clearance to deliver this genuine SCHNEIDER part to your facility, regardless of location.

How to select the correct coil voltage for a SCHNEIDER contactor?

Select the coil voltage based on your control circuit supply. For the LC1DT200A6BNE, the coil is rated 48V AC at 60Hz. Ensure your control voltage matches this rating to avoid coil burnout or failure. Always verify the coil voltage against your system's nominal supply before installation.

Used in

Common applications for SCHNEIDER
Motor starting in conveyor systems — Schneider Altistart ATS 22 soft starters (e.g., ATS22D17S6U) reduce inrush current.
Speed control for industrial pumps — Schneider Altivar ATV320 VFDs (e.g., ATV320U55N4W) provide variable flow regulation.
Machine safety interlocking — Schneider XPSUAF13AP safety relays monitor emergency stop circuits on assembly lines.
Panel-mounted control stations — Schneider XB5 flush push buttons (ZB5AA5) serve as start/stop operators in MCCs.
Heavy-duty motor switching — Schneider LC1G150LSEA contactors handle 150 A loads in compressor and crusher applications.
Emergency stop actuation — Schneider 9001K mushroom-head push buttons (9001KR25R) provide red, momentary stop functions.

SCHNEIDER Products

3G Electric supplies SCHNEIDER non-reversing iec contactors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Non-reversing IEC contactor with 4 poles and 4 normally open contacts, rated for 200 A. Coil voltage is 48 V AC at 60 Hz. Integrated surge suppression included. Used for switching power circuits such as motors, lighting, and heating loads in industrial applications
SCHNEIDER
Non-reversing IEC contactor with 4 poles and 4 normally open contacts, rated for 200 A. Coil voltage is 48 V AC at 60 Hz. Integrated surge suppression included. Used for switching power circuits such as motors, lighting, and heating loads in industrial applications
Non-reversing IEC contactor with 4 poles and 4 normally open contacts, rated for 200 A. Coil voltage is 48V AC at 60Hz, with integrated surge suppression. Suitable for switching power circuits in motor control, lighting, and heating applications
SCHNEIDER
Non-reversing IEC contactor with 4 poles and 4 normally open contacts, rated for 200 A. Coil voltage is 48V AC at 60Hz, with integrated surge suppression. Suitable for switching power circuits in motor control, lighting, and heating applications
Non-reversing IEC contactor with 3 poles and 3 normally open contacts, rated for 150 A. Coil voltage is 48V AC at 60Hz. Integrated surge suppression is included. Used for switching and controlling electrical loads in motor control, lighting, and power distribution systems
SCHNEIDER
Non-reversing IEC contactor with 3 poles and 3 normally open contacts, rated for 150 A. Coil voltage is 48V AC at 60Hz. Integrated surge suppression is included. Used for switching and controlling electrical loads in motor control, lighting, and power distribution systems
SCHNEIDER LC1D50A6EHE is a 3-pole non-reversing IEC contactor with 3 normally open contacts, rated at 50 A. The coil operates at 48V AC (60 Hz) and includes integrated surge suppression. This contactor is used for switching motors, lighting, and power circuits in industrial control panels and automation systems
SCHNEIDER
SCHNEIDER LC1D50A6EHE is a 3-pole non-reversing IEC contactor with 3 normally open contacts, rated at 50 A. The coil operates at 48V AC (60 Hz) and includes integrated surge suppression. This contactor is used for switching motors, lighting, and power circuits in industrial control panels and automation systems
SCHNEIDER ELECTRIC IEC Contactor: Non-Reversing, 4 Poles, 4NO Contacts, 200 A, 120V AC/48V AC Coil (MPN LC1DT200A6EHE)
SCHNEIDER
SCHNEIDER ELECTRIC IEC Contactor: Non-Reversing, 4 Poles, 4NO Contacts, 200 A, 120V AC/48V AC Coil (MPN LC1DT200A6EHE)
This SCHNEIDER non-reversing IEC contactor features 3 poles with 3 normally open contacts, rated for 115 A. It operates with a 48V AC coil at 60Hz and includes integrated surge suppression. Suitable for motor starting, lighting, and power distribution in industrial control systems
SCHNEIDER
This SCHNEIDER non-reversing IEC contactor features 3 poles with 3 normally open contacts, rated for 115 A. It operates with a 48V AC coil at 60Hz and includes integrated surge suppression. Suitable for motor starting, lighting, and power distribution in industrial control systems

More from SCHNEIDER

View all SCHNEIDER parts
Non-reversing IEC contactor with 3 poles and 3 normally open contacts. Rated 18 A with a 24 VDC coil and integrated surge suppression. Used for switching 3-phase loads in motor control and power distribution applications
SCHNEIDER
Non-reversing IEC contactor with 3 poles and 3 normally open contacts. Rated 18 A with a 24 VDC coil and integrated surge suppression. Used for switching 3-phase loads in motor control and power distribution applications
This SCHNEIDER non-reversing IEC contactor features 3 poles and 3 normally open contacts, rated at 115 A with a 120V AC coil. Integrated surge suppression is included. Typical applications include switching power circuits in motor control, lighting, and heating systems
SCHNEIDER
This SCHNEIDER non-reversing IEC contactor features 3 poles and 3 normally open contacts, rated at 115 A with a 120V AC coil. Integrated surge suppression is included. Typical applications include switching power circuits in motor control, lighting, and heating systems
Non-reversing IEC contactor with 3 poles and 3 normally open contacts, rated 150 A. Coil voltage 240V AC or 480V AC. Includes integrated surge suppression. Used for switching and controlling three-phase loads such as motors, lighting, and power circuits in industrial applications
SCHNEIDER
Non-reversing IEC contactor with 3 poles and 3 normally open contacts, rated 150 A. Coil voltage 240V AC or 480V AC. Includes integrated surge suppression. Used for switching and controlling three-phase loads such as motors, lighting, and power circuits in industrial applications
SCHNEIDER LC1D80G7 is a 3-pole non-reversing IEC contactor rated for 80 A with a 120V AC coil and 3 normally open contacts. It is used for switching motors, lighting, and other electrical loads in industrial control panels and power distribution systems. This model does not include integrated surge suppression
SCHNEIDER
SCHNEIDER LC1D80G7 is a 3-pole non-reversing IEC contactor rated for 80 A with a 120V AC coil and 3 normally open contacts. It is used for switching motors, lighting, and other electrical loads in industrial control panels and power distribution systems. This model does not include integrated surge suppression
The SCHNEIDER DPE18G7 is a 3-pole non-reversing IEC magnetic contactor with 3 normally open contacts, rated for 18 A and a 120V AC coil. It is used for switching motors, lighting, and other inductive loads in industrial control panels, such as in manufacturing, HVAC, and pumping systems. This model does not include integrated surge suppression
SCHNEIDER
The SCHNEIDER DPE18G7 is a 3-pole non-reversing IEC magnetic contactor with 3 normally open contacts, rated for 18 A and a 120V AC coil. It is used for switching motors, lighting, and other inductive loads in industrial control panels, such as in manufacturing, HVAC, and pumping systems. This model does not include integrated surge suppression
Non-reversing IEC magnetic contactor with 3 poles and 3 normally open (NO) contacts. Rated for 18 A with a 24 V DC coil. No integrated surge suppression. Used for switching and controlling electrical loads in motor control and industrial automation applications
SCHNEIDER
Non-reversing IEC magnetic contactor with 3 poles and 3 normally open (NO) contacts. Rated for 18 A with a 24 V DC coil. No integrated surge suppression. Used for switching and controlling electrical loads in motor control and industrial automation applications
Non-reversing IEC contactor with 4 normally open poles rated for 330 A. Coil voltage is 48V AC at 60Hz. Spring-loaded wire termination type. No integrated surge suppression. Suitable for switching high-power loads in motor control and power distribution applications
SCHNEIDER
Non-reversing IEC contactor with 4 normally open poles rated for 330 A. Coil voltage is 48V AC at 60Hz. Spring-loaded wire termination type. No integrated surge suppression. Suitable for switching high-power loads in motor control and power distribution applications
3-pole non-reversing IEC contactor with 3 normally open contacts, rated 9 A and 110V AC coil. Suitable for switching three-phase motors, lighting, and HVAC loads in industrial control panels and automation systems. No integrated surge suppression
SCHNEIDER
3-pole non-reversing IEC contactor with 3 normally open contacts, rated 9 A and 110V AC coil. Suitable for switching three-phase motors, lighting, and HVAC loads in industrial control panels and automation systems. No integrated surge suppression