Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

3G Electric
SCHNEIDER LR2K0312 IEC Thermal Overload Relay - IEC Thermal Overload Relays
SCHNEIDERIEC Thermal Overload Relays

SCHNEIDER LR2K0312 IEC Thermal Overload Relay

The SCHNEIDER Overload Relay: Thermal Protection (MPN LR2K0312) is an IEC thermal overload relay with three poles, designed for use with TeSys Deca and TeSys K contactors. It features integrated bimetallic elements…

SKU 3G-OTH-39678

Brand
SCHNEIDER
Item
LR2K0312 IEC Thermal Overload Relay
Part Number
LR2K0312
Category
IEC Thermal Overload Relays
Available to Order
Also known as:LR2K0312SCHNEIDER
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

SCHNEIDER
Manufacturer Part Number
LR2K0312
Type
1NO/1NC, Phase Loss Sensitivity
Poles
3
Compatible Contactors
TeSys K Models
Auxiliary Contact Form
1NO/1NC
Maximum Voltage Rating
250V DC (Signaling Circuit)
Phase Loss Sensitivity
Yes
Thermal Units Required
None (Relay Includes Integrated Bimetallic Elements)
Terminal Connection Type
Screw Clamp Terminals
Compatible Contactor Series
TeSys Deca

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

SCHNEIDER Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The SCHNEIDER Overload Relay: Thermal Protection (MPN LR2K0312) is an IEC thermal overload relay with three poles, designed for use with TeSys Deca and TeSys K contactors. It features integrated bimetallic elements, eliminating the need for separate thermal units, and includes 1NO/1NC auxiliary contacts with a maximum signaling circuit voltage rating of 250V DC. The relay provides phase loss sensitivity and uses screw clamp terminals for secure wiring connections.

Frequently Asked Questions

What is the SCHNEIDER LR2K0312 overload relay used for?

The SCHNEIDER LR2K0312 is an IEC thermal overload relay that protects three-phase motors from overheating caused by overload or phase loss. It integrates bimetallic elements and 1NO/1NC auxiliary contacts, and is compatible with TeSys Deca and TeSys K contactors for industrial motor control applications.

What are the specifications of the SCHNEIDER LR2K0312 overload relay?

The SCHNEIDER LR2K0312 is a 3-pole thermal overload relay with 1NO/1NC auxiliary contacts, a maximum signaling circuit voltage of 250V DC, and phase loss sensitivity. It uses screw clamp terminals and includes integrated bimetallic elements, so no separate thermal units are required. It is compatible with TeSys K contactors.

Where to buy the SCHNEIDER LR2K0312 overload relay worldwide?

3G Electric supplies the SCHNEIDER LR2K0312 overload relay worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your location. Contact us for pricing and lead time on this IEC thermal overload relay with phase loss protection.

How to install the SCHNEIDER LR2K0312 overload relay?

Mount the SCHNEIDER LR2K0312 directly onto a compatible TeSys K contactor using the screw clamp terminals for secure wiring. Ensure the motor full-load current is within the relay's adjustment range. Follow standard IEC installation practices and verify phase loss sensitivity settings per the motor protection requirements.

Used in

Common applications for SCHNEIDER
Motor starting in conveyor systems — Schneider Altistart ATS 22 soft starters (e.g., ATS22D17S6U) reduce inrush current.
Speed control for industrial pumps — Schneider Altivar ATV320 VFDs (e.g., ATV320U55N4W) provide variable flow regulation.
Machine safety interlocking — Schneider XPSUAF13AP safety relays monitor emergency stop circuits on assembly lines.
Panel-mounted control stations — Schneider XB5 flush push buttons (ZB5AA5) serve as start/stop operators in MCCs.
Heavy-duty motor switching — Schneider LC1G150LSEA contactors handle 150 A loads in compressor and crusher applications.
Emergency stop actuation — Schneider 9001K mushroom-head push buttons (9001KR25R) provide red, momentary stop functions.
Not sure this is the right part? Photo-identify it

SCHNEIDER Products

3G Electric supplies SCHNEIDER iec thermal overload relays. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from SCHNEIDER

View all SCHNEIDER parts
IEC thermal overload relay with integrated bimetallic elements for motor protection. Rated 7 A to 10 A, 690V AC, 3 poles, with 1NO/1NC auxiliary contacts and phase loss sensitivity. Screw clamp terminals. Compatible with TeSys Deca contactors (9 to 38 A models)
SCHNEIDER
IEC thermal overload relay with integrated bimetallic elements for motor protection. Rated 7 A to 10 A, 690V AC, 3 poles, with 1NO/1NC auxiliary contacts and phase loss sensitivity. Screw clamp terminals. Compatible with TeSys Deca contactors (9 to 38 A models)
IEC thermal overload relay with integrated bimetallic elements for motor protection. Rated 60 A to 100 A, 3 poles, 690V AC maximum. Features 1NO/1NC auxiliary contacts, screw clamp terminals, and phase loss sensitivity. Compatible with TeSys Deca contactors (115 to 150 Amp models)
SCHNEIDER
IEC thermal overload relay with integrated bimetallic elements for motor protection. Rated 60 A to 100 A, 3 poles, 690V AC maximum. Features 1NO/1NC auxiliary contacts, screw clamp terminals, and phase loss sensitivity. Compatible with TeSys Deca contactors (115 to 150 Amp models)
IEC thermal overload relay with integrated bimetallic elements for motor protection against overload and phase loss. Rated 48 A to 65 A, 3 poles, with 1NO/1NC auxiliary contacts and screw clamp terminals. Compatible with TeSys Deca contactors (80 to 95 A models). Maximum voltage rating 1000V AC
SCHNEIDER
IEC thermal overload relay with integrated bimetallic elements for motor protection against overload and phase loss. Rated 48 A to 65 A, 3 poles, with 1NO/1NC auxiliary contacts and screw clamp terminals. Compatible with TeSys Deca contactors (80 to 95 A models). Maximum voltage rating 1000V AC
3-pole IEC thermal overload relay with integrated bimetallic elements for motor protection. Features phase loss sensitivity, screw clamp terminals, and 1NO/1NC auxiliary contacts. Current setting range 2.5 A to 4 A, maximum voltage 690V AC. Designed for use with TeSys Deca contactors (9 to 38 A models). Suitable for protecting motors in industrial applications such as pumps, fans, and conveyors
SCHNEIDER
3-pole IEC thermal overload relay with integrated bimetallic elements for motor protection. Features phase loss sensitivity, screw clamp terminals, and 1NO/1NC auxiliary contacts. Current setting range 2.5 A to 4 A, maximum voltage 690V AC. Designed for use with TeSys Deca contactors (9 to 38 A models). Suitable for protecting motors in industrial applications such as pumps, fans, and conveyors
SCHNEIDER
SCHNEIDER
IEC thermal overload relay with integrated bimetallic elements for motor protection against overcurrent and phase loss. Rated 6.4 A to 32 A, 3 poles, with 1NO/1NC auxiliary contacts and maximum voltage 690V AC. Compatible with TeSys Deca contactors (1 to 32 A models). No separate thermal units required
IEC thermal overload relay with integrated bimetallic elements, rated 5.5 A – 8 A and 690V AC. Features 1NO/1NC auxiliary contacts, phase loss sensitivity, and screw clamp terminals. Compatible with TeSys Deca contactors (9 to 38 A models). Provides motor overload protection in industrial control panels
SCHNEIDER
IEC thermal overload relay with integrated bimetallic elements, rated 5.5 A – 8 A and 690V AC. Features 1NO/1NC auxiliary contacts, phase loss sensitivity, and screw clamp terminals. Compatible with TeSys Deca contactors (9 to 38 A models). Provides motor overload protection in industrial control panels

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first