Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

SCHNEIDER Power Meter: Three Phase, 90/600V AC/DC, 5 A Current - Schneider Electric Energy Meters
SCHNEIDERSchneider Electric Energy Meters

SCHNEIDER Power Meter: Three Phase, 90/600V AC/DC, 5 A Current

The SCHNEIDER ELECTRIC Power Meter (SKU 3G-OTH-29652) is a three-phase energy meter from Schneider Electric that measures apparent power with ±0.20% accuracy. It accepts an input voltage of 90/600V AC/DC and is…

SKU 3G-OTH-29652

Also listed as: METSEEM 3550 · METSEEM-3550

Brand
SCHNEIDER
Item
Power Meter: Three Phase, 90/600V AC/DC, 5 A Current
Category
Schneider Electric Energy Meters
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

SCHNEIDER
Manufacturer Part Number
METSEEM3550
Type
±0.20% Accuracy
AC/DC
90/600V
Phase
Three
UNSPSC
41113708
Current
5 A
Accuracy
±0.20%
Measures
Apparent Power
Input Voltage
90/600V AC/DC
Country of Origin
USA (subject to change)

Datasheet Content

Product data sheet METSEEM3550 Characteristics PowerLogic EM3500 DIN rail meter - Modbus 2 quadrant - current transformer Main Range PowerLogic Range of product PowerLogic EM3500 Device short name EM3550 Product or Component Energy meter Type Metering type Voltage U21, U32, U13, V1, V2, V3 Peak demand power PM, QM, SM Demand power P, Q, S Current I1, I2, I3, Iavg It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Complementary Poles description 3P + N Type of measurement Active and reactive power total Active and reactive power per phase Apparent power total Apparent power per phase Power factor total The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. Power factor per phase This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. Peak demand power Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Current Voltage Frequency Device Application Sub billing Partial meter Accuracy class Class 0.2S power IEC 62053-22 Class 0.2S energy IEC 62053-22 Class 0.2S power ANSI C12.20 Class 0.2S energy ANSI C12.20 Measurement accuracy Power +/- 0.2 % Energy +/- 0.2 % Input type Split core current transducer 0.333 V or 1 V Rated voltage 90…347 V Network Frequency 50 Hz 60 Hz Technology Type Electronic Display Type Backlit LCD Measurement current 5…32000 A Display digits 5 Information displayed Status and alert Communication with system Input/Output status Error Tx activity Rx activity Instant power per usage Tamperproof of settings Protected by access code Communication port protocol Modbus RTU 1200…38400 bps - 2-wire Communication port support Screw terminal block RS485 Communication Service Total cumulated energy Total cumulated active energy Data recording Energy consumption logs Demand intervals Fixed or rolling block External synchronisation to communication Jan 11, 2022 1 Local signalling Red LED threshold reached Green flashing LED output signal Number of Outputs 1 alarm output 1 pulse [Ue] rated operational voltage 90...347 V AC 50/60 Hz between phase and neutral UL 156...600 V AC 50/60 Hz between phases UL 90...300 V AC 50/60 Hz between phase and neutral CE 125...300 V DC Power consumption in VA 5 VA 347 V AC between phase and neutral) 5 VA 600 V AC between phases) Power consumption in W 3 W 300 V Ride-through time 100 ms 120 V AC Mounting Mode Clip-on By screws Mounting Support DIN rail Standards UL 508 IEC 61010-1 CSA C22.2 No 14-05 Product certifications CE IEC 61010 CULus UL 508 Environment Relative humidity 0…95 % Ambient air temperature for operation -22…158 °F (-30…70 °C) Ambient Air Temperature for Storage -40…185 °F (-40…85 °C) Color Dark grey 9 mm pitches 12 Width 4.21 in (107 mm) Height 3.58 in (91 mm) Depth 2.32 in (59 mm) Ordering and shipping details Category 09798 - POWERLOGIC EM3500 SERIES Discount Schedule PL1 GTIN 785901302605 Nbr. of units in pkg. 1 Package weight(Lbs) 8.00 lb(US) (3.629 kg) Returnability Yes Packing Units Unit Type of Package 1 PCE Package 1 Height 3.58 in (9.1 cm) Package 1 width 4.21 in (10.7 cm) Package 1 Length 2.32 in (5.9 cm) Offer Sustainability California proposition 65 WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov REACh Regulation REACh Declaration EU RoHS Directive Compliant EU RoHS Declaration Mercury free Yes RoHS exemption information Yes China RoHS Regulation China RoHS Declaration WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. 2

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

SCHNEIDER Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The SCHNEIDER ELECTRIC Power Meter (SKU 3G-OTH-29652) is a three-phase energy meter from Schneider Electric that measures apparent power with ±0.20% accuracy. It accepts an input voltage of 90/600V AC/DC and is identified by manufacturer part number METSEEM3550.

Frequently Asked Questions

What is the SCHNEIDER ELECTRIC Power Meter METSEEM3550 used for?

The SCHNEIDER ELECTRIC Power Meter METSEEM3550 is a three-phase energy meter used to measure apparent power in industrial electrical systems. It is suitable for monitoring power consumption and power quality in manufacturing plants, commercial buildings, and utility substations where ±0.20% accuracy and 90/600V AC/DC input are required.

What are the specifications of the SCHNEIDER ELECTRIC Power Meter METSEEM3550?

The SCHNEIDER ELECTRIC Power Meter METSEEM3550 has ±0.20% accuracy, measures apparent power, and accepts 90/600V AC/DC input voltage with 5 A current. It is a three-phase device from Schneider Electric, identified by manufacturer part number METSEEM3550. These specs ensure reliable energy monitoring in industrial environments.

Where to buy the SCHNEIDER ELECTRIC Power Meter METSEEM3550 worldwide?

3G Electric supplies the SCHNEIDER ELECTRIC Power Meter METSEEM3550 to customers worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your location. Contact us for pricing and lead time on this three-phase energy meter with ±0.20% accuracy.

How to install the SCHNEIDER ELECTRIC Power Meter METSEEM3550?

Install the SCHNEIDER ELECTRIC Power Meter METSEEM3550 by following standard three-phase meter wiring practices: connect voltage inputs (90/600V AC/DC) and current inputs (5 A) per the manufacturer's diagram. Ensure proper grounding and verify phase rotation. For detailed steps, consult the Schneider Electric installation manual for the METSEEM3550.

Used in

Common applications for SCHNEIDER
Motor starting in conveyor systems — Schneider Altistart ATS 22 soft starters (e.g., ATS22D17S6U) reduce inrush current.
Speed control for industrial pumps — Schneider Altivar ATV320 VFDs (e.g., ATV320U55N4W) provide variable flow regulation.
Machine safety interlocking — Schneider XPSUAF13AP safety relays monitor emergency stop circuits on assembly lines.
Panel-mounted control stations — Schneider XB5 flush push buttons (ZB5AA5) serve as start/stop operators in MCCs.
Heavy-duty motor switching — Schneider LC1G150LSEA contactors handle 150 A loads in compressor and crusher applications.
Emergency stop actuation — Schneider 9001K mushroom-head push buttons (9001KR25R) provide red, momentary stop functions.

SCHNEIDER Products

3G Electric supplies SCHNEIDER schneider electric energy meters. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
SIEMENS Power Meter: Three Phase, 240V, 0.5 A Current, ±0.30% Accuracy, Freq/Power/Volt, 1 (MPN US2:ENCL4224001TCX)
Siemens
SIEMENS Power Meter: Three Phase, 240V, 0.5 A Current, ±0.30% Accuracy, Freq/Power/Volt, 1 (MPN US2:ENCL4224001TCX)
SIEMENS Power Meter: Three Phase, 480V, 0.5 A Current, ±0.35% Accuracy, Freq/Power/Volt, 1 (MPN US2:ENCL4248001TCX)
Siemens
SIEMENS Power Meter: Three Phase, 480V, 0.5 A Current, ±0.35% Accuracy, Freq/Power/Volt, 1 (MPN US2:ENCL4248001TCX)
SIEMENS Power Meter: Three Phase, 110 to 340V DC/95 to 240V AC, 5 A Current, ±0.20% Accuracy, 12 (MPN 7KM42120BA003AA0)
Siemens
SIEMENS Power Meter: Three Phase, 110 to 340V DC/95 to 240V AC, 5 A Current, ±0.20% Accuracy, 12 (MPN 7KM42120BA003AA0)
SIEMENS Power Meter: Three Phase, 240V, 0.5 A Current, ±0.30% Accuracy, Freq/Power/Volt, 1 (MPN US2:ENCL3224001TCX)
Siemens
SIEMENS Power Meter: Three Phase, 240V, 0.5 A Current, ±0.30% Accuracy, Freq/Power/Volt, 1 (MPN US2:ENCL3224001TCX)
SIEMENS Power Meter: Three Phase, 240V, 0.5 A Current, ±1% Accuracy, Freq/Power/Volt, 1 (MPN US2:ENCL3124001TCX)
Siemens
SIEMENS Power Meter: Three Phase, 240V, 0.5 A Current, ±1% Accuracy, Freq/Power/Volt, 1 (MPN US2:ENCL3124001TCX)

More from SCHNEIDER

View all SCHNEIDER parts
SCHNEIDER ELECTRIC Power Meter: Three Phase, 120/480V AC/125/250V DC, 1 A_5 A Current, No Enclosure (MPN METSEPM5563)
SCHNEIDER
SCHNEIDER ELECTRIC Power Meter: Three Phase, 120/480V AC/125/250V DC, 1 A_5 A Current, No Enclosure (MPN METSEPM5563)
SCHNEIDER ELECTRIC Power Meter: Three Phase, 90/600V AC/DC, 5 A Current, ±0.20% Accuracy (MPN METSEEM3555)
SCHNEIDER
SCHNEIDER ELECTRIC Power Meter: Three Phase, 90/600V AC/DC, 5 A Current, ±0.20% Accuracy (MPN METSEEM3555)
SCHNEIDER ELECTRIC Power Meter: Three Phase, 120/480V AC/125/250V DC, 1 A_5 A Current, No Enclosure (MPN METSEPM5560)
SCHNEIDER
SCHNEIDER ELECTRIC Power Meter: Three Phase, 120/480V AC/125/250V DC, 1 A_5 A Current, No Enclosure (MPN METSEPM5560)
SCHNEIDER ELECTRIC Power Meter: Three Phase, 90/600V AC/DC, 5 A Current, ±0.20% Accuracy (MPN METSEEM3502)
SCHNEIDER
SCHNEIDER ELECTRIC Power Meter: Three Phase, 90/600V AC/DC, 5 A Current, ±0.20% Accuracy (MPN METSEEM3502)
SCHNEIDER ELECTRIC Power Meter: Three Phase, 120/480V AC/125/250V DC, 1 A_5 A Current, No Enclosure (MPN METSEPM5110)
SCHNEIDER
SCHNEIDER ELECTRIC Power Meter: Three Phase, 120/480V AC/125/250V DC, 1 A_5 A Current, No Enclosure (MPN METSEPM5110)
SCHNEIDER ELECTRIC Power Meter: Three Phase, 120/480V AC/125/250V DC, 1 A_5 A Current, No Enclosure (MPN METSEPM5330)
SCHNEIDER
SCHNEIDER ELECTRIC Power Meter: Three Phase, 120/480V AC/125/250V DC, 1 A_5 A Current, No Enclosure (MPN METSEPM5330)
SCHNEIDER ELECTRIC Power Meter: Three Phase, 90/600V AC/DC, 5 A Current, ±0.20% Accuracy (MPN METSEEM3560)
SCHNEIDER
SCHNEIDER ELECTRIC Power Meter: Three Phase, 90/600V AC/DC, 5 A Current, ±0.20% Accuracy (MPN METSEEM3560)