SCHNEIDER TK-1301 Dual-Temperature Pneumatic Thermostat

The SCHNEIDER TK-1301 is a Day/Night pneumatic thermostat with a temperature control range of 55° to 85°F. It features 2 Pipes, High Volume air flow output and Direct thermostat action: 15 psig (Day) and 20 psig…

SKU 3G-OTH-69701

Also listed as: TK1301 · TK 1301

Brand
SCHNEIDER
Item
TK-1301 Dual-Temperature Pneumatic Thermostat
Category
Dual-Temperature Thermostats
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

SCHNEIDER
Manufacturer Part Number
TK-1301
Type
High Volume Pipes/Air Flow Output
Pipes
2
Thermostat Action
Direct - 15 psig (Day), Direct - 20 psig (Night)
Pneumatic Thermostat Type
Day/Night
Temperature Control Range
55° to 85°F (Day/Night)
Number of Pipes/Air Flow Output
2 Pipes, High Volume
Mounting Direction/Includes Cover
Horizontal/Vertical, Yes

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

SCHNEIDER Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The SCHNEIDER TK-1301 is a Day/Night pneumatic thermostat with a temperature control range of 55° to 85°F. It features 2 Pipes, High Volume air flow output and Direct thermostat action: 15 psig (Day) and 20 psig (Night). The unit supports Horizontal/Vertical mounting and includes a cover.

Frequently Asked Questions

What is the SCHNEIDER TK-1301 pneumatic thermostat used for?

The SCHNEIDER TK-1301 is a Day/Night pneumatic thermostat used in commercial HVAC systems to regulate temperature between 55° and 85°F. It is designed for 2-pipe, high-volume air flow applications, providing direct-acting control at 15 psig (Day) and 20 psig (Night).

What are the specifications of the SCHNEIDER TK-1301?

The SCHNEIDER TK-1301 is a Day/Night pneumatic thermostat with a temperature range of 55° to 85°F. It features 2 pipes with high-volume air flow output, direct action at 15 psig (Day) and 20 psig (Night), and supports horizontal or vertical mounting. A cover is included.

Where to buy the SCHNEIDER TK-1301 worldwide?

You can source the SCHNEIDER TK-1301 through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations. Contact us for availability and lead time.

How to install the SCHNEIDER TK-1301 pneumatic thermostat?

Mount the SCHNEIDER TK-1301 horizontally or vertically using the included cover. Connect the two high-volume air pipes per the direct-acting setup: 15 psig for Day and 20 psig for Night. Ensure proper air supply and follow standard pneumatic thermostat installation practices.

Used in

Common applications for SCHNEIDER
Motor starting in conveyor systems — Schneider Altistart ATS 22 soft starters (e.g., ATS22D17S6U) reduce inrush current.
Speed control for industrial pumps — Schneider Altivar ATV320 VFDs (e.g., ATV320U55N4W) provide variable flow regulation.
Machine safety interlocking — Schneider XPSUAF13AP safety relays monitor emergency stop circuits on assembly lines.
Panel-mounted control stations — Schneider XB5 flush push buttons (ZB5AA5) serve as start/stop operators in MCCs.
Heavy-duty motor switching — Schneider LC1G150LSEA contactors handle 150 A loads in compressor and crusher applications.
Emergency stop actuation — Schneider 9001K mushroom-head push buttons (9001KR25R) provide red, momentary stop functions.

SCHNEIDER Products

3G Electric supplies SCHNEIDER dual-temperature thermostats. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Pneumatic day/night thermostat for HVAC systems requiring separate day and night setpoints. Features reverse action at 15 psig (day) and 20 psig (night), with 2-pipe high-volume air flow output. Temperature control range 55° to 85°F. Includes cover; mounts horizontally or vertically
SCHNEIDER
Pneumatic day/night thermostat for HVAC systems requiring separate day and night setpoints. Features reverse action at 15 psig (day) and 20 psig (night), with 2-pipe high-volume air flow output. Temperature control range 55° to 85°F. Includes cover; mounts horizontally or vertically
Single-temperature pneumatic thermostat with reverse action, designed for 2-pipe high volume air flow systems. Temperature control range of 55° to 85°F. Includes cover for horizontal or vertical mounting. Suitable for HVAC temperature control in commercial buildings
SCHNEIDER
Single-temperature pneumatic thermostat with reverse action, designed for 2-pipe high volume air flow systems. Temperature control range of 55° to 85°F. Includes cover for horizontal or vertical mounting. Suitable for HVAC temperature control in commercial buildings
Pneumatic thermostat for summer/winter dual-temperature control in HVAC systems. Temperature range 55° to 85°F. Direct action at 25 psig, reverse at 16 psig. Two-pipe high-volume air flow output. Mounts horizontally or vertically; cover included
SCHNEIDER
Pneumatic thermostat for summer/winter dual-temperature control in HVAC systems. Temperature range 55° to 85°F. Direct action at 25 psig, reverse at 16 psig. Two-pipe high-volume air flow output. Mounts horizontally or vertically; cover included
Single-temperature pneumatic thermostat with direct action and a temperature control range of 55° to 85°F. Designed for 1 pipe low volume air flow output and vertical mounting, includes cover. Used in HVAC pneumatic control loops for regulating heating or cooling valves
SCHNEIDER
Single-temperature pneumatic thermostat with direct action and a temperature control range of 55° to 85°F. Designed for 1 pipe low volume air flow output and vertical mounting, includes cover. Used in HVAC pneumatic control loops for regulating heating or cooling valves
Single-temperature pneumatic thermostat with reverse action for modulating low-volume air flow in HVAC systems. Temperature control range of 55° to 85°F. Designed for vertical mounting with included cover. Suitable for zone temperature regulation in commercial buildings
SCHNEIDER
Single-temperature pneumatic thermostat with reverse action for modulating low-volume air flow in HVAC systems. Temperature control range of 55° to 85°F. Designed for vertical mounting with included cover. Suitable for zone temperature regulation in commercial buildings

More from SCHNEIDER

View all SCHNEIDER parts
Remote reset pneumatic thermostat with 3 high-volume pipes. Temperature control range 65° to 85°F. Direct action at 25 psig, reverse action at 16 psig. Mounts horizontally or vertically; cover not included. Used in HVAC systems for space temperature regulation
SCHNEIDER
Remote reset pneumatic thermostat with 3 high-volume pipes. Temperature control range 65° to 85°F. Direct action at 25 psig, reverse action at 16 psig. Mounts horizontally or vertically; cover not included. Used in HVAC systems for space temperature regulation
Day/Night pneumatic thermostat with direct action, 17 psig day and 21 psig night. Temperature range 55° to 85°F day, 50° to 80°F night. Three-pipe high-volume air flow output. Mounts horizontally or vertically; cover included. Used in commercial HVAC zone control for scheduled temperature setback
SCHNEIDER
Day/Night pneumatic thermostat with direct action, 17 psig day and 21 psig night. Temperature range 55° to 85°F day, 50° to 80°F night. Three-pipe high-volume air flow output. Mounts horizontally or vertically; cover included. Used in commercial HVAC zone control for scheduled temperature setback
Pneumatic thermostat for heating and cooling systems with a temperature control range of 55° to 85°F. Operates with 2 high-volume air flow pipes and provides direct action at 15 psig and 20 psig. Suitable for horizontal or vertical mounting; includes cover
SCHNEIDER
Pneumatic thermostat for heating and cooling systems with a temperature control range of 55° to 85°F. Operates with 2 high-volume air flow pipes and provides direct action at 15 psig and 20 psig. Suitable for horizontal or vertical mounting; includes cover
Summer/winter pneumatic thermostat for 2-pipe high-volume HVAC systems. Temperature control range 55° to 85°F. Direct action at 16 psig, reverse action at 25 psig. Mounts horizontally or vertically; cover included
SCHNEIDER
Summer/winter pneumatic thermostat for 2-pipe high-volume HVAC systems. Temperature control range 55° to 85°F. Direct action at 16 psig, reverse action at 25 psig. Mounts horizontally or vertically; cover included
Day/night pneumatic thermostat for HVAC systems. Temperature control range: 55° to 85°F day, 50° to 80°F night. Direct action at 17 psig (day) and 21 psig (night). Two-pipe high volume air flow output. Mounts horizontally or vertically; cover included
SCHNEIDER
Day/night pneumatic thermostat for HVAC systems. Temperature control range: 55° to 85°F day, 50° to 80°F night. Direct action at 17 psig (day) and 21 psig (night). Two-pipe high volume air flow output. Mounts horizontally or vertically; cover included
Pneumatic thermostat for heating and cooling control in commercial HVAC systems. Temperature range 55° to 85°F with 2-pipe high-volume air flow output. Direct action at 15 psig, reverse action at 20 psig. Mounts horizontally or vertically; includes cover
SCHNEIDER
Pneumatic thermostat for heating and cooling control in commercial HVAC systems. Temperature range 55° to 85°F with 2-pipe high-volume air flow output. Direct action at 15 psig, reverse action at 20 psig. Mounts horizontally or vertically; includes cover
This SCHNEIDER pneumatic thermostat provides dual-temperature control for day and night operation, with a range of 55° to 85°F. It features 2-pipe high volume air flow output and direct action at 15 psig (day) and 20 psig (night). Suitable for horizontal or vertical mounting, the unit includes a cover. Commonly used in commercial HVAC systems to regulate pneumatic actuators in buildings with separate occupied and unoccupied setpoints
SCHNEIDER
This SCHNEIDER pneumatic thermostat provides dual-temperature control for day and night operation, with a range of 55° to 85°F. It features 2-pipe high volume air flow output and direct action at 15 psig (day) and 20 psig (night). Suitable for horizontal or vertical mounting, the unit includes a cover. Commonly used in commercial HVAC systems to regulate pneumatic actuators in buildings with separate occupied and unoccupied setpoints
Dual-temperature pneumatic thermostat for heating and cooling applications. Temperature control range 55° to 85°F. 2-pipe high-volume air flow output. Direct action at 20 psig, reverse action at 15 psig. Includes cover for horizontal or vertical mounting
SCHNEIDER