The SIEMENS NEMA Magnetic Motor Starter is a non-reversing starter with an electronic overload, designed for three-phase applications. This NEMA Size 3-1/2 unit features a 115 A rating, a coil voltage of…

SKU 3G-OTH-44077

Brand
Siemens
Item
14IUH32AH NEMA Size 3-1/2 Non-Reversing Starter with
Category
Non-Reversing Starters with Electronic Overloads
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Siemens
Manufacturer Part Number
14IUH32AH
Type
NEMA Size 3-1/2, 115 A
Phase
Three
Poles
3
AC Coil
480V
Coil Voltage
380-440/440-480V AC
Signaling Features
Pilot Light
Auxiliary Contact Form
1NO
Thermal Units Required
None (Not Applicable to Electronic Overloads)
Terminal Connection Type
Screw Terminals
Auxiliary Contacts Included
1NO

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Siemens Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The SIEMENS NEMA Magnetic Motor Starter is a non-reversing starter with an electronic overload, designed for three-phase applications. This NEMA Size 3-1/2 unit features a 115 A rating, a coil voltage of 380-440/440-480V AC, and includes a pilot light and 1NO auxiliary contact. It uses screw terminals and requires no thermal units, as specified by the electronic overload design.

Frequently Asked Questions

What is the SIEMENS NEMA Magnetic Motor Starter used for?

This non-reversing starter with electronic overload is used to start and protect three-phase AC motors in industrial applications such as pumps, fans, and conveyors. It provides reliable motor control and overload protection without requiring thermal units, making it suitable for demanding environments.

What are the specifications of the SIEMENS NEMA Magnetic Motor Starter 14IUH32AH?

This SIEMENS starter is NEMA Size 3-1/2, rated 115 A, with a coil voltage of 380-440/440-480V AC. It features three poles, screw terminals, a pilot light, and one normally open auxiliary contact. The electronic overload design eliminates the need for thermal units.

Where to buy the SIEMENS NEMA Magnetic Motor Starter 14IUH32AH worldwide?

3G Electric supplies this SIEMENS NEMA Magnetic Motor Starter worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time on this part.

How to select the correct SIEMENS NEMA Magnetic Motor Starter for a motor?

Match the starter's NEMA size and current rating to your motor's full-load amps and voltage. For this SIEMENS Size 3-1/2 unit rated 115 A, ensure your motor's FLA does not exceed 115 A and that the coil voltage matches your control circuit (380-440/440-480V AC).

Used in

Common applications for Siemens
District cooling plants — LME73 + RWF55 for condenser-water modulation
Inflight catering and food-processing steam boilers — LMG22 with SQN90 air-fuel cross-damper
Hospital steam-plant redundancy — LME41 with QRA2 UV flame detection for dual-fuel boilers
Semiconductor fab process heat — LME23 and SKP55 gas valves on hot-oil heater skids
Container-terminal reefer-deck heating — LMG22 retrofit onto legacy burner racks

Siemens Products

3G Electric supplies Siemens non-reversing starters with electronic overloads. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Three-pole non-reversing motor starter with electronic overload protection, NEMA Size 3-1/2 rated 115 A. Coil voltage 190-220/220-240V AC for three-phase motors. Includes pilot light, one normally open auxiliary contact, and screw terminals. No thermal units required
Siemens
Three-pole non-reversing motor starter with electronic overload protection, NEMA Size 3-1/2 rated 115 A. Coil voltage 190-220/220-240V AC for three-phase motors. Includes pilot light, one normally open auxiliary contact, and screw terminals. No thermal units required
Non-reversing magnetic motor starter for three-phase motors. NEMA Size 4, 135 A rating, 3 poles. Coil voltage 380-440/440-480V AC. Includes pilot light and 1NO auxiliary contact. Screw terminals. Electronic overload protection integrated, no thermal units required. Used for starting and protecting motors in applications such as pumps, fans, and conveyors
Siemens
Non-reversing magnetic motor starter for three-phase motors. NEMA Size 4, 135 A rating, 3 poles. Coil voltage 380-440/440-480V AC. Includes pilot light and 1NO auxiliary contact. Screw terminals. Electronic overload protection integrated, no thermal units required. Used for starting and protecting motors in applications such as pumps, fans, and conveyors
Three-pole non-reversing motor starter with electronic overload protection, NEMA Size 4 rated for 135 A. Includes a 110/120V AC coil, pilot light, and one normally open auxiliary contact. Screw terminals for wiring. Suitable for starting and stopping three-phase motors in industrial applications such as pumps, fans, conveyors, and compressors
Siemens
Three-pole non-reversing motor starter with electronic overload protection, NEMA Size 4 rated for 135 A. Includes a 110/120V AC coil, pilot light, and one normally open auxiliary contact. Screw terminals for wiring. Suitable for starting and stopping three-phase motors in industrial applications such as pumps, fans, conveyors, and compressors
Non-reversing magnetic motor starter with electronic overload protection, NEMA Size 4, rated 135 A, three-phase, three poles. Coil voltage 208V AC. Includes pilot light and one normally open auxiliary contact. Screw terminals. Suitable for starting and stopping three-phase motors in constant-direction applications such as pumps, fans, and conveyors
Siemens
Non-reversing magnetic motor starter with electronic overload protection, NEMA Size 4, rated 135 A, three-phase, three poles. Coil voltage 208V AC. Includes pilot light and one normally open auxiliary contact. Screw terminals. Suitable for starting and stopping three-phase motors in constant-direction applications such as pumps, fans, and conveyors
Non-reversing magnetic motor starter for three-phase AC motors. NEMA Size 3-1/2 rated 115 A with 208V AC coil. Includes electronic overload protection, pilot light, one normally open auxiliary contact, and screw terminals. Suitable for starting and stopping motors in applications such as conveyors, pumps, fans, and compressors
Siemens
Non-reversing magnetic motor starter for three-phase AC motors. NEMA Size 3-1/2 rated 115 A with 208V AC coil. Includes electronic overload protection, pilot light, one normally open auxiliary contact, and screw terminals. Suitable for starting and stopping motors in applications such as conveyors, pumps, fans, and compressors
SIEMENS NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 3-1/2, 115 A, 120V AC Coil (MPN 14IUH32AF)
Siemens
SIEMENS NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 3-1/2, 115 A, 120V AC Coil (MPN 14IUH32AF)

More from Siemens

View all Siemens parts
SIEMENS NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 0, 18 A, 120V AC Coil (MPN 14CUC32AF)
Siemens
SIEMENS NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 0, 18 A, 120V AC Coil (MPN 14CUC32AF)
SIEMENS NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 0, 18 A, 120V AC Coil (MPN 14CUB32AF)
Siemens
SIEMENS NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 0, 18 A, 120V AC Coil (MPN 14CUB32AF)
Non-reversing magnetic motor starter for three-phase motors, NEMA Size 1-3/4 rated 40 A. Features electronic overload protection, 480V AC coil (dual voltage 380-440/440-480V), one normally open auxiliary contact, pilot light, and screw terminals. Suitable for starting and stopping motors in industrial applications such as pumps, conveyors, and compressors
Siemens
Non-reversing magnetic motor starter for three-phase motors, NEMA Size 1-3/4 rated 40 A. Features electronic overload protection, 480V AC coil (dual voltage 380-440/440-480V), one normally open auxiliary contact, pilot light, and screw terminals. Suitable for starting and stopping motors in industrial applications such as pumps, conveyors, and compressors
Non-reversing motor starter with electronic overload protection for 3-phase motors. Rated 7 A at 24V DC, 3 poles. Includes LED status indicator and 1NO/1NC auxiliary contacts. Used for starting and protecting motors in industrial automation, HVAC, and pump control applications
Siemens
Non-reversing motor starter with electronic overload protection for 3-phase motors. Rated 7 A at 24V DC, 3 poles. Includes LED status indicator and 1NO/1NC auxiliary contacts. Used for starting and protecting motors in industrial automation, HVAC, and pump control applications
SIEMENS NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 2, 45 A, 120V AC Coil (MPN 14FUF32AF)
Siemens
SIEMENS NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 2, 45 A, 120V AC Coil (MPN 14FUF32AF)
Non-reversing motor starter for three-phase motors up to 135 A. NEMA Size 4 with electronic overload, 190-220/220-240V AC coil, pilot light, and 1NO auxiliary contact. Screw terminals. Used for starting and protecting motors in industrial applications such as conveyors, pumps, and compressors
Siemens
Non-reversing motor starter for three-phase motors up to 135 A. NEMA Size 4 with electronic overload, 190-220/220-240V AC coil, pilot light, and 1NO auxiliary contact. Screw terminals. Used for starting and protecting motors in industrial applications such as conveyors, pumps, and compressors
Three-pole non-reversing magnetic motor starter with electronic overload protection, rated 27 A at NEMA Size 1. Coil voltage dual-rated 110-120/220-240V AC. Includes pilot light and one normally open auxiliary contact. Screw terminals. Suitable for starting and stopping three-phase motors in applications such as conveyors, pumps, and compressors
Siemens
Three-pole non-reversing magnetic motor starter with electronic overload protection, rated 27 A at NEMA Size 1. Coil voltage dual-rated 110-120/220-240V AC. Includes pilot light and one normally open auxiliary contact. Screw terminals. Suitable for starting and stopping three-phase motors in applications such as conveyors, pumps, and compressors
This Siemens NEMA Size 3 non-reversing starter is rated 90 A and designed for three-phase motor control. It features an electronic overload that eliminates the need for thermal units, a 480V AC coil (380-440/440-480V AC), screw terminals, one normally open auxiliary contact, and a pilot light. Suitable for starting and protecting motors in applications such as pumps, fans, and conveyors
Siemens
This Siemens NEMA Size 3 non-reversing starter is rated 90 A and designed for three-phase motor control. It features an electronic overload that eliminates the need for thermal units, a 480V AC coil (380-440/440-480V AC), screw terminals, one normally open auxiliary contact, and a pilot light. Suitable for starting and protecting motors in applications such as pumps, fans, and conveyors