Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Image not available
SiemensElectronic Air Differential Pressure Sensors

Siemens Differential Pressure Sensor: -0.25 in wc to 0.25 in wc, ±1.00% Accuracy

The Siemens 590-510 is an electronic air differential pressure sensor with a range of -0.25 in wc to 0.25 in wc. It provides a 0 to 10V DC output with ±1.00% accuracy and requires a 0 to 10V DC power supply. The…

SKU 3G-OTH-68429

Brand
Siemens
Item
Differential Pressure Sensor: -0.25 in wc to 0.25 in wc, ±1.00% Accuracy
Category
Electronic Air Differential Pressure Sensors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

Siemens
Manufacturer Part Number
590-510
Type
±1.00% Accuracy
DC
0 to 10V
Output
0 to 10V DC
Accuracy
±1.00%
Power Required
0 to 10V DC
Loop Resistance
100 ohms
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Siemens Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Siemens 590-510 is an electronic air differential pressure sensor with a range of -0.25 in wc to 0.25 in wc. It provides a 0 to 10V DC output with ±1.00% accuracy and requires a 0 to 10V DC power supply. The sensor has a loop resistance of 100 ohms.

Frequently Asked Questions

What is the Siemens 590-510 differential pressure sensor used for?

The Siemens 590-510 measures low air pressure differences in HVAC systems, clean rooms, and industrial ventilation. It detects filter loading, fan status, and airflow changes with ±1.00% accuracy over a -0.25 in wc to 0.25 in wc range.

What are the specifications of the Siemens 590-510 differential pressure sensor?

The Siemens 590-510 has a range of -0.25 in wc to 0.25 in wc, ±1.00% accuracy, and a 0 to 10V DC output. It requires a 0 to 10V DC power supply and has a loop resistance of 100 ohms. The manufacturer part number is 590-510.

Where to buy the Siemens 590-510 differential pressure sensor worldwide?

3G Electric supplies the Siemens 590-510 differential pressure sensor worldwide. We handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time on this precision HVAC component.

How to install the Siemens 590-510 differential pressure sensor?

Mount the Siemens 590-510 in a dry location with pressure ports oriented downward to prevent moisture ingress. Connect the 0 to 10V DC power supply and output wiring per the wiring diagram. Use tubing of appropriate diameter and ensure no kinks for accurate readings.

Used in

Common applications for Siemens
District cooling plants — LME73 + RWF55 for condenser-water modulation
Inflight catering and food-processing steam boilers — LMG22 with SQN90 air-fuel cross-damper
Hospital steam-plant redundancy — LME41 with QRA2 UV flame detection for dual-fuel boilers
Semiconductor fab process heat — LME23 and SKP55 gas valves on hot-oil heater skids
Container-terminal reefer-deck heating — LMG22 retrofit onto legacy burner racks

Siemens Products

3G Electric supplies Siemens electronic air differential pressure sensors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Similar products

Matched by specification & description
Siemens
Siemens
SIEMENS Room Pressure Monitor: +/- 0.25" WC (62.5 Pa), P1, Terminal Block, 2.17 in Display Size (MPN 547-313B). Key specifications — Manufacturer Part Number: 547-313B; Brand: SIEMENS; Accuracy: ±0.25% of Full Scale; Analog Inputs: 0 to 5 V DC; Analog Outputs: 0 to 5V DC (3-Wire); Display Size: 2.17 in; Measurement Range: +/- 0.25" WC (62.5 Pa); Operating Humidity - Maximum: 95% RH (Non-Condensing).
Siemens
Siemens
SIEMENS Room Pressure Monitor: +/- 0.10" WC (25 Pa), P1, Terminal Block, 2.17 in Display Size (MPN 547-312A). Key specifications — Manufacturer Part Number: 547-312A; Brand: SIEMENS; Accuracy: ±0.5% of Full Scale; Analog Inputs: 0 to 5 V DC; Analog Outputs: 4 to 20 mA (2-Wire); Display Size: 2.17 in; Measurement Range: +/- 0.10" WC (25 Pa); Operating Humidity - Maximum: 95% RH (Non-Condensing).
Siemens
Siemens
SIEMENS Room Pressure Monitor: +/- 0.25" WC (62.5 Pa), P1, Terminal Block, 2.17 in Display Size (MPN 547-103A). Key specifications — Manufacturer Part Number: 547-103A; Brand: SIEMENS; Accuracy: ±0.5% of Full Scale; Analog Outputs: SPDT Relay; Display Size: 2.17 in; Measurement Range: +/- 0.25" WC (62.5 Pa); Operating Humidity - Maximum: 95% RH (Non-Condensing); Operating Temperature Range: 32°F to 120°F.
Siemens
Siemens
SIEMENS Room Pressure Monitor: +/- 0.25" WC (62.5 Pa), P1, Terminal Block, 2.17 in Display Size (MPN 547-103B). Key specifications — Manufacturer Part Number: 547-103B; Brand: SIEMENS; Accuracy: ±0.25% of Full Scale; Analog Outputs: SPDT Relay; Display Size: 2.17 in; Measurement Range: +/- 0.25" WC (62.5 Pa); Operating Humidity - Maximum: 95% RH (Non-Condensing); Operating Temperature Range: 32°F to 120°F.
Siemens
Siemens
SIEMENS Room Pressure Monitor: +/- 0.25" WC (62.5 Pa), BACnet, Terminal Block, 2.17 in Display Size (MPN 547-323B). Key specifications — Manufacturer Part Number: 547-323B; Brand: SIEMENS; Accuracy: ±0.25% of Full Scale; Analog Inputs: 0 to 10 V DC; Analog Outputs: 0 to 10V DC (3-Wire); Display Size: 2.17 in; Measurement Range: +/- 0.25" WC (62.5 Pa); Operating Humidity - Maximum: 95% RH (Non-Condensing).
Siemens
Siemens
SIEMENS Room Pressure Monitor: +/- 0.50" WC (125 Pa), P1, Terminal Block, 2.17 in Display Size (MPN 547-104B). Key specifications — Manufacturer Part Number: 547-104B; Brand: SIEMENS; Accuracy: ±0.25% of Full Scale; Analog Outputs: SPDT Relay; Display Size: 2.17 in; Measurement Range: +/- 0.50" WC (125 Pa); Operating Humidity - Maximum: 95% RH (Non-Condensing); Operating Temperature Range: 32°F to 120°F.

More from Siemens

View all Siemens parts
Siemens
Siemens
Differential Pressure Sensor: 0.65 in wc to 0.65 in wc, ±0.40% Accuracy, 0 to 10V DC, 4 to 20mA (MPN 590-781). Key specifications — Accuracy: ±0.40%; Output: 4 to 20mA; Loop Resistance: 100 ohms; Power Required: 0 to 10V DC; Brand: SIEMENS.
Siemens
Siemens
Differential Pressure Sensor: 0.5 in wc to 0.65 in wc, ±0.40% Accuracy, 0 to 10V DC, 4 to 20mA (MPN 590-782). Key specifications — Accuracy: ±0.40%; Output: 4 to 20mA; Loop Resistance: 100 ohms; Power Required: 0 to 10V DC; Brand: SIEMENS.
Siemens
Siemens
Differential Pressure Sensor: 1 in wc to 1 in wc, ±0.40% Accuracy, 0 to 10V DC, 4 to 20mA, 100 ohms (MPN 590-780). Key specifications — Accuracy: ±0.40%; Output: 4 to 20mA; Loop Resistance: 100 ohms; Power Required: 0 to 10V DC; Brand: SIEMENS.