Siemens Definite Purpose Magnetic Contactor: 3 Poles, 277V AC, 75 A - Non-Reversing Definite Purpose Contactors
SiemensNon-Reversing Definite Purpose Contactors

Siemens Definite Purpose Magnetic Contactor: 3 Poles, 277V AC, 75 A

The SIEMENS 42 Series Definite Purpose Magnetic Contactor is a three-pole, non-reversing HVACR definite purpose contactor with a 3NO main pole contact form. It features a coil voltage of 240/277V AC, a maximum…

SKU 3G-OTH-43650

Brand
Siemens
Item
Definite Purpose Magnetic Contactor: 3 Poles, 277V AC, 75 A
Category
Non-Reversing Definite Purpose Contactors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Siemens
Manufacturer Part Number
42FE35AL
Series
42 Series
Type
75 A, Non-Reversing
AC
277V
Phase
Three
Coil Voltage
240/277V AC
Mounting Style
Surface
Contactor Style
HVACR Definite Purpose Contactor
Main Pole Contact Form
3NO
Maximum Voltage Rating
600V AC
Terminal Connection Type
Screw Terminals

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Siemens Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The SIEMENS 42 Series Definite Purpose Magnetic Contactor is a three-pole, non-reversing HVACR definite purpose contactor with a 3NO main pole contact form. It features a coil voltage of 240/277V AC, a maximum voltage rating of 600V AC, and screw terminals for surface mounting.

Frequently Asked Questions

What is the SIEMENS 42FE35AL definite purpose contactor used for?

The SIEMENS 42FE35AL is a three-pole, non-reversing definite purpose contactor designed for HVACR applications such as compressors, fan motors, and refrigeration units. It switches loads up to 75 A at 277V AC and is rated for 600V AC maximum, making it suitable for commercial and industrial heating, ventilation, and air conditioning systems.

What are the specifications of the SIEMENS 42FE35AL contactor?

The SIEMENS 42FE35AL is a 3-pole, non-reversing definite purpose contactor with a coil voltage of 240/277V AC, a maximum voltage rating of 600V AC, and a current rating of 75 A. It features a 3NO main pole contact form, screw terminals, and surface mounting. It is part of the SIEMENS 42 Series and is designed for three-phase HVACR systems.

Where to buy the SIEMENS 42FE35AL contactor worldwide?

3G Electric supplies the SIEMENS 42FE35AL definite purpose contactor to customers worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your location. Contact us for pricing and lead time on this HVACR contactor.

How to install the SIEMENS 42FE35AL definite purpose contactor?

Mount the SIEMENS 42FE35AL on a flat surface using the screw terminals provided. Ensure the coil voltage matches your control circuit (240/277V AC). Connect the three-phase power lines to the line-side terminals and the load to the load-side terminals. Always follow local electrical codes and de-energize the circuit before installation.

Used in

Common applications for Siemens
District cooling plants — LME73 + RWF55 for condenser-water modulation
Inflight catering and food-processing steam boilers — LMG22 with SQN90 air-fuel cross-damper
Hospital steam-plant redundancy — LME41 with QRA2 UV flame detection for dual-fuel boilers
Semiconductor fab process heat — LME23 and SKP55 gas valves on hot-oil heater skids
Container-terminal reefer-deck heating — LMG22 retrofit onto legacy burner racks

Siemens Products

3G Electric supplies Siemens non-reversing definite purpose contactors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
SIEMENS Definite Purpose Magnetic Contactor: 3 Poles, 480V AC, 75 A, Non-Reversing (MPN 42FE35AH)
Siemens
SIEMENS Definite Purpose Magnetic Contactor: 3 Poles, 480V AC, 75 A, Non-Reversing (MPN 42FE35AH)
SIEMENS Definite Purpose Magnetic Contactor: 3 Poles, 120V AC, 75 A, Non-Reversing (MPN 42FE35AF)
Siemens
SIEMENS Definite Purpose Magnetic Contactor: 3 Poles, 120V AC, 75 A, Non-Reversing (MPN 42FE35AF)
SIEMENS Definite Purpose Magnetic Contactor: 3 Poles, 277V AC, 90 A, Non-Reversing (MPN 42GE35AL)
Siemens
SIEMENS Definite Purpose Magnetic Contactor: 3 Poles, 277V AC, 90 A, Non-Reversing (MPN 42GE35AL)
SIEMENS Definite Purpose Magnetic Contactor: 2 Poles, 480V AC, 40 A, Non-Reversing (MPN 45GG20AH)
Siemens
SIEMENS Definite Purpose Magnetic Contactor: 2 Poles, 480V AC, 40 A, Non-Reversing (MPN 45GG20AH)
SIEMENS Definite Purpose Magnetic Contactor: 1 + N Poles, 480V AC, 40 A, Non-Reversing (MPN 45GG10AHA)
Siemens
SIEMENS Definite Purpose Magnetic Contactor: 1 + N Poles, 480V AC, 40 A, Non-Reversing (MPN 45GG10AHA)
SIEMENS Definite Purpose Magnetic Contactor: 1 + N Poles, 120V AC, 40 A, Non-Reversing (MPN 45GG10AFA)
Siemens
SIEMENS Definite Purpose Magnetic Contactor: 1 + N Poles, 120V AC, 40 A, Non-Reversing (MPN 45GG10AFA)

More from Siemens

View all Siemens parts
Three-phase HVACR definite purpose contactor with 1NO main pole contact form. Rated 30 A at 480V AC, maximum 600V AC. Coil voltage 380-440/440-480V AC. Surface mount with screw terminals. Used for switching loads such as compressors, fan motors, and pumps in commercial and industrial systems
Siemens
Three-phase HVACR definite purpose contactor with 1NO main pole contact form. Rated 30 A at 480V AC, maximum 600V AC. Coil voltage 380-440/440-480V AC. Surface mount with screw terminals. Used for switching loads such as compressors, fan motors, and pumps in commercial and industrial systems
This Siemens definite purpose contactor is a non-reversing, single-phase device with 2 poles and a 2NO main pole contact form. It operates on a 24V AC coil, rated for 30 A with a maximum voltage of 600V AC. Surface mount design with quick disconnect and screw/box lug terminals. Suitable for switching loads in HVAC, refrigeration, and industrial equipment such as compressors, fans, and pumps
Siemens
This Siemens definite purpose contactor is a non-reversing, single-phase device with 2 poles and a 2NO main pole contact form. It operates on a 24V AC coil, rated for 30 A with a maximum voltage of 600V AC. Surface mount design with quick disconnect and screw/box lug terminals. Suitable for switching loads in HVAC, refrigeration, and industrial equipment such as compressors, fans, and pumps
Three-phase, non-reversing definite purpose contactor from the 42 Series. Rated 30 A with 2 normally open main poles. Coil voltage 380-440/440-480V AC, maximum voltage 600V AC. Surface mount with screw terminals. Suitable for HVACR applications such as controlling compressors, fans, and pumps
Siemens
Three-phase, non-reversing definite purpose contactor from the 42 Series. Rated 30 A with 2 normally open main poles. Coil voltage 380-440/440-480V AC, maximum voltage 600V AC. Surface mount with screw terminals. Suitable for HVACR applications such as controlling compressors, fans, and pumps
Single-phase definite purpose contactor with 2 poles and 2 normally open main contacts. Rated 30 A, coil voltage 110/110-120V AC, maximum 600V AC. Surface mount with quick disconnect and screw/box lug terminals. Used for switching loads such as compressors, fans, and pumps in HVAC and refrigeration equipment
Siemens
Single-phase definite purpose contactor with 2 poles and 2 normally open main contacts. Rated 30 A, coil voltage 110/110-120V AC, maximum 600V AC. Surface mount with quick disconnect and screw/box lug terminals. Used for switching loads such as compressors, fans, and pumps in HVAC and refrigeration equipment
Non-reversing definite purpose contactor for HVACR applications such as controlling compressors, fans, and pumps. Features 1 normally open main pole, 40 A rating, 240/277V AC coil voltage, and 600V AC maximum voltage. Three-phase operation with screw terminals for surface mounting
Siemens
Non-reversing definite purpose contactor for HVACR applications such as controlling compressors, fans, and pumps. Features 1 normally open main pole, 40 A rating, 240/277V AC coil voltage, and 600V AC maximum voltage. Three-phase operation with screw terminals for surface mounting
Three-phase, non-reversing definite purpose contactor with 3 normally open main poles. Rated 90 A at 480V AC, maximum 600V AC. Coil voltage 380-440/440-480V AC. Surface mount with screw terminals. Suitable for switching motors, compressors, fans, and pumps in HVACR and industrial equipment
Siemens
Three-phase, non-reversing definite purpose contactor with 3 normally open main poles. Rated 90 A at 480V AC, maximum 600V AC. Coil voltage 380-440/440-480V AC. Surface mount with screw terminals. Suitable for switching motors, compressors, fans, and pumps in HVACR and industrial equipment
SIEMENS Definite Purpose Magnetic Contactor: 1 + N Poles, 24V AC, 40 A, Non-Reversing (MPN 45GG10AJA)
Siemens
SIEMENS Definite Purpose Magnetic Contactor: 1 + N Poles, 24V AC, 40 A, Non-Reversing (MPN 45GG10AJA)
SIEMENS Definite Purpose Magnetic Contactor: 3 Poles, 24V AC, 75 A, Non-Reversing (MPN 42FE35AJ)
Siemens
SIEMENS Definite Purpose Magnetic Contactor: 3 Poles, 24V AC, 75 A, Non-Reversing (MPN 42FE35AJ)