Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

SJE-RHOMBUS TA-EZ-02HTB Liquid-Level Alarm - Liquid-Level Alarms
SJE-RHOMBUSLiquid-Level Alarms

SJE-RHOMBUS TA-EZ-02HTB Liquid-Level Alarm

The SJE-RHOMBUS Water Alarm: High Level is a liquid-level alarm with a 240V AC nameplate voltage, featuring an audio/visual alarm at 82 dB and one alarm input. It includes a tether float switch, operates…

SKU 3G-OTH-94153

Also listed as: TAEZ02HTB · TA EZ 02HTB

Brand
SJE-RHOMBUS
Item
TA-EZ-02HTB Liquid-Level Alarm
Category
Liquid-Level Alarms
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

SJE-RHOMBUS
Manufacturer Part Number
TA-EZ-02HTB
Type
Auto, 82 dB, Audio/Visual, 3R
AC
240V
Alarm Inputs
1
Battery Backup
No
Nameplate Voltage
240V AC
Switch Type Included
Tether Float

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

SJE-RHOMBUS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The SJE-RHOMBUS Water Alarm: High Level is a liquid-level alarm with a 240V AC nameplate voltage, featuring an audio/visual alarm at 82 dB and one alarm input. It includes a tether float switch, operates automatically, and is rated NEMA 3R. This unit does not include battery backup.

Frequently Asked Questions

What is the SJE-RHOMBUS Water Alarm TA-EZ-02HTB used for?

The SJE-RHOMBUS Water Alarm TA-EZ-02HTB is a high-level liquid-level alarm used in sump, sewage, or effluent basins to alert personnel of rising water. It provides an 82 dB audio/visual signal and includes a tether float switch for automatic detection, suitable for indoor or outdoor NEMA 3R enclosures.

What are the specifications of the SJE-RHOMBUS Water Alarm TA-EZ-02HTB?

The SJE-RHOMBUS Water Alarm TA-EZ-02HTB operates at 240V AC, includes one alarm input, and features an 82 dB audio/visual alarm. It comes with a tether float switch, has no battery backup, and is rated NEMA 3R for weather-resistant use. The manufacturer part number is TA-EZ-02HTB.

Where to buy the SJE-RHOMBUS Water Alarm TA-EZ-02HTB worldwide?

3G Electric supplies the SJE-RHOMBUS Water Alarm TA-EZ-02HTB worldwide. As a global industrial equipment distributor since 1990, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time on this liquid-level alarm.

How to install the SJE-RHOMBUS Water Alarm TA-EZ-02HTB?

Mount the NEMA 3R enclosure in a dry or sheltered location. Connect the tether float switch to the alarm input per the wiring diagram. Set the tether length to activate at the desired high water level. Test the 82 dB alarm by lifting the float. Ensure 240V AC power is disconnected during installation.

Used in

Common applications for SJE-RHOMBUS
Municipal wastewater lift stations — SJE-RHOMBUS simplex grinder pump panels (e.g., NEX Grinder 1 ph, Simplex - 67C) for single-pump sewage systems
Commercial building sump pump control — SJE-RHOMBUS multi-purpose control panels (e.g., EZS11W914X3A6A8AC10E15A) for 120V AC sump pumps with visual alerts
Industrial effluent treatment — SJE-RHOMBUS duplex grinder panels (e.g., VSGD-240-3-16.5) for alternating pump operation in 208-240V AC three-phase systems
Residential septic systems — SJE-RHOMBUS float bracket assemblies (e.g., 4 Float Bracket with Mounting Device) for mounting level switches in septic tanks
Chemical dosing stations — SJE-RHOMBUS timed dose panels (e.g., EZP11W6C0H10E17A) for controlled discharge of chemicals at 120V AC
Outdoor pump stations — SJE-RHOMBUS outdoor-rated panels (e.g., EZP11W6C0H1JV8G10EP17A) with NEMA 3R enclosures for weather-exposed installations

SJE-RHOMBUS Products

3G Electric supplies SJE-RHOMBUS liquid-level alarms. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Ceiling-mount occupancy sensor combining Passive Infrared (PIR) and Microphonic detection for automatic lighting control. Operates on 15 to 24V DC or 24V AC/DC. Connects via Digital Cat5 Cable; load rating is determined by the control unit
SENSOR SWITCH
Ceiling-mount occupancy sensor combining Passive Infrared (PIR) and Microphonic detection for automatic lighting control. Operates on 15 to 24V DC or 24V AC/DC. Connects via Digital Cat5 Cable; load rating is determined by the control unit
Ceiling-mount occupancy sensor combining Passive Infrared (PIR) and Microphonic detection for automatic lighting control. Operates on 15 to 24V DC or 24V AC/DC. Suitable for commercial spaces such as offices, classrooms, and meeting rooms to reduce energy consumption by turning lights off when unoccupied
SENSOR SWITCH
Ceiling-mount occupancy sensor combining Passive Infrared (PIR) and Microphonic detection for automatic lighting control. Operates on 15 to 24V DC or 24V AC/DC. Suitable for commercial spaces such as offices, classrooms, and meeting rooms to reduce energy consumption by turning lights off when unoccupied
Prewired, normally open solid state switch for pneumatic cylinder position sensing. Operates on 24V DC with a current range of 5 to 40 mA. Composite body with 2 wires. Suitable for non-contact detection in industrial automation applications such as packaging, material handling, and assembly lines
SMC
Prewired, normally open solid state switch for pneumatic cylinder position sensing. Operates on 24V DC with a current range of 5 to 40 mA. Composite body with 2 wires. Suitable for non-contact detection in industrial automation applications such as packaging, material handling, and assembly lines
Passive infrared (PIR) ceiling-mount occupancy sensor for automatic lighting control. Operates on 15 to 24V DC or 24V AC/DC. Connects via Digital Cat5 Cable; rating depends on control unit. Suitable for commercial spaces such as offices and meeting rooms
SENSOR SWITCH
Passive infrared (PIR) ceiling-mount occupancy sensor for automatic lighting control. Operates on 15 to 24V DC or 24V AC/DC. Connects via Digital Cat5 Cable; rating depends on control unit. Suitable for commercial spaces such as offices and meeting rooms
Passive infrared (PIR) occupancy sensor for ceiling-mount installation. Operates on 15 to 24V DC or 24V AC/DC power. Connects via Digital Cat5 Cable; load rating depends on control unit. Suitable for automatic lighting control in commercial spaces such as offices, conference rooms, and open-plan areas
SENSOR SWITCH
Passive infrared (PIR) occupancy sensor for ceiling-mount installation. Operates on 15 to 24V DC or 24V AC/DC power. Connects via Digital Cat5 Cable; load rating depends on control unit. Suitable for automatic lighting control in commercial spaces such as offices, conference rooms, and open-plan areas
TELEMECANIQUE SENSORS Water Pump Switch: Std, 5 psi – 65 psi, 1/4" FNPS, 20 psi / 40 psi ON/OFF (MPN 9013FSG2J20U)
TELEMECANIQUE SENSORS
TELEMECANIQUE SENSORS Water Pump Switch: Std, 5 psi – 65 psi, 1/4" FNPS, 20 psi / 40 psi ON/OFF (MPN 9013FSG2J20U)

More from SJE-RHOMBUS

View all SJE-RHOMBUS parts
This liquid-level alarm provides audio and visual notification at 80 dB when water reaches a high level in sump, sewage, or effluent basins. It operates on 4.5V DC, includes two alarm inputs, and comes with a tether float switch. Battery backup ensures continued operation during power loss
SJE-RHOMBUS
This liquid-level alarm provides audio and visual notification at 80 dB when water reaches a high level in sump, sewage, or effluent basins. It operates on 4.5V DC, includes two alarm inputs, and comes with a tether float switch. Battery backup ensures continued operation during power loss
Liquid-level alarm for sump, sewage, or effluent basins. Provides 82 dB audio/visual alert when high water is detected. Includes tether float switch for automatic operation. Rated NEMA 3R for outdoor or damp locations. 120V AC, single alarm input, no battery backup
SJE-RHOMBUS
Liquid-level alarm for sump, sewage, or effluent basins. Provides 82 dB audio/visual alert when high water is detected. Includes tether float switch for automatic operation. Rated NEMA 3R for outdoor or damp locations. 120V AC, single alarm input, no battery backup
Liquid-level alarm with 120V AC input, 85 dB audio/visual alarm, and automatic operation. Includes one tether float switch for high-level detection. NEMA 3R enclosure suitable for damp or outdoor installations. No battery backup
SJE-RHOMBUS
Liquid-level alarm with 120V AC input, 85 dB audio/visual alarm, and automatic operation. Includes one tether float switch for high-level detection. NEMA 3R enclosure suitable for damp or outdoor installations. No battery backup
Liquid-level alarm for monitoring high water levels in sump pits, basins, or tanks. Features an 87 dB audio/visual alarm, one alarm input, and a tether float switch. Includes battery backup for continued operation during power loss. Operates at 120V AC with auto-resetting function
SJE-RHOMBUS
Liquid-level alarm for monitoring high water levels in sump pits, basins, or tanks. Features an 87 dB audio/visual alarm, one alarm input, and a tether float switch. Includes battery backup for continued operation during power loss. Operates at 120V AC with auto-resetting function
SJE-RHOMBUS Dual Level Alarm: High Level, 120V AC, Auto, 82 dB, Audio/Visual, 2 Alarm Inputs, 3R (MPN 1052374)
SJE-RHOMBUS
SJE-RHOMBUS Dual Level Alarm: High Level, 120V AC, Auto, 82 dB, Audio/Visual, 2 Alarm Inputs, 3R (MPN 1052374)
Liquid-level alarm with 80 dB audio/visual alert and tether float switch. Operates at 4.5V DC with two alarm inputs and built-in battery backup for continued monitoring during power loss. Used to detect high water levels in sump, sewage, or effluent basins
SJE-RHOMBUS
Liquid-level alarm with 80 dB audio/visual alert and tether float switch. Operates at 4.5V DC with two alarm inputs and built-in battery backup for continued monitoring during power loss. Used to detect high water levels in sump, sewage, or effluent basins
Liquid-level alarm for monitoring low water levels in sump, sewage, or effluent basins. Features an 87 dB audio/visual alarm, one alarm input, and a tether float switch. Battery backup maintains operation during power loss. Operates on 120V AC
SJE-RHOMBUS
Liquid-level alarm for monitoring low water levels in sump, sewage, or effluent basins. Features an 87 dB audio/visual alarm, one alarm input, and a tether float switch. Battery backup maintains operation during power loss. Operates on 120V AC