We supply parts. EXW Singapore: collect from our office.

SQUARE D B22.0 Thermal Unit, Trip Class 20 - Electrical
SQUAREElectrical

SQUARE D B22.0 Thermal Unit, Trip Class 20

The SQUARE D B22.0 Thermal Unit is a reliable overload protection component designed for industrial motor starters. With a Trip Class of 20, it provides a delayed trip response suitable for applications with high…

SKU 3G-OTH-43899

Also listed as: B220 · B22 0 · B22-0

Brand
SQUARE
Item
D B22.0 Thermal Unit, Trip Class 20
Part Number
B22.0
Category
Electrical
UNSPSC
39121029 — Isolation transformer
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Payment
Invoicing in SGD. Bank transfer and corporate PO accepted.

Technical Specifications

SQUARE
Manufacturer Part Number
B22.0

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.
Ask a question

Ask a question

SQUARE Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The SQUARE D B22.0 Thermal Unit is a reliable overload protection component designed for industrial motor starters. With a Trip Class of 20, it provides a delayed trip response suitable for applications with high inrush currents. This thermal unit is identified by manufacturer part number B22.0, ensuring precise compatibility with compatible Square D starters.

Procurement buyers in Singapore can request SGD quotes for the B22.0, with GST handled for local orders. Benefit from fast delivery across Singapore and Southeast Asia, while worldwide shipping is available for global projects.

Frequently Asked Questions

What is the trip class of the SQUARE D B22.0 thermal unit?

The SQUARE D B22.0 has a Trip Class of 20, indicating a 20-second trip time at 600% of the thermal current rating.

Can I get a quote in SGD and fast delivery in Singapore?

Yes, 3G Electric provides SGD quotes on request, handles GST for Singapore buyers, and offers fast delivery across Singapore and Southeast Asia.

Used in

Common applications for SQUARE
Commercial building lighting control — Square D 8903LO60V04 (6-pole, 30 A, 277V AC coil) for switching large-area lighting in offices and retail spaces.
Warehouse lighting — Square D 8903LO1000V02 (10-pole, 30 A, 120V AC coil) for centralized control of high-bay lighting circuits.
Parking lot lighting — Square D 8903SPO2V04 (3-pole, 60 A, 277V AC coil) for remote switching of exterior lighting groups.
Manufacturing facility lighting — Square D 8903LO1200V02 (12-pole, 30 A, 120V AC coil) for multi-circuit lighting control in production areas.
Industrial facility lighting — Square D 8903SMO2V02 (3-pole, 30 A, 120V AC coil) for switching lighting in small zones or individual rooms.
Large-scale lighting systems — Square D 8903LO80V02 (8-pole, 30 A, 120V AC coil) for controlling multiple lighting circuits from a single point.
Not sure this is the right part? Photo-identify it→

SQUARE Products

3G Electric supplies SQUARE electrical. We supply genuine products and their technical documentation.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

Compatible alternatives & equivalents

More from SQUARE

View all SQUARE parts →
Overload relay heater element for motor starters. Provides thermal overload protection by tripping the circuit when current exceeds the rated threshold. Trip Class 20. Use in industrial motor controllers to prevent overheating and equipment failure
SQUARE
Overload relay heater element for motor starters. Provides thermal overload protection by tripping the circuit when current exceeds the rated threshold. Trip Class 20. Use in industrial motor controllers to prevent overheating and equipment failure
Thermal overload relay component for motor starters, providing inverse-time protection against sustained overcurrent. Trip Class 20. Used in industrial motor control panels, conveyors, pumps, and HVAC equipment
SQUARE
Thermal overload relay component for motor starters, providing inverse-time protection against sustained overcurrent. Trip Class 20. Used in industrial motor control panels, conveyors, pumps, and HVAC equipment
Overload protection device for motor starters and contactors. Trip class 20 indicates maximum time to trip under locked-rotor current. Protects motors from damage due to prolonged overcurrent conditions in industrial automation, HVAC, and pump systems
SQUARE
Overload protection device for motor starters and contactors. Trip class 20 indicates maximum time to trip under locked-rotor current. Protects motors from damage due to prolonged overcurrent conditions in industrial automation, HVAC, and pump systems
The SQUARE B2.10 thermal unit is an overload relay component for motor starters, providing inverse-time thermal protection against sustained overcurrent. It is used in motor control panels, HVAC systems, and conveyor drives to help prevent motor damage from prolonged overload conditions
SQUARE
The SQUARE B2.10 thermal unit is an overload relay component for motor starters, providing inverse-time thermal protection against sustained overcurrent. It is used in motor control panels, HVAC systems, and conveyor drives to help prevent motor damage from prolonged overload conditions
Thermal unit for overload protection in motor starters. Trip class 20 provides delayed tripping for moderate starting loads. Used in industrial motor control panels and HVAC systems to protect motors from sustained overcurrent
SQUARE
Thermal unit for overload protection in motor starters. Trip class 20 provides delayed tripping for moderate starting loads. Used in industrial motor control panels and HVAC systems to protect motors from sustained overcurrent
Thermal unit for motor starters and controllers, providing overload protection by monitoring current and heat. Trip class 20. Used in industrial motor control panels and HVAC equipment
SQUARE
Thermal unit for motor starters and controllers, providing overload protection by monitoring current and heat. Trip class 20. Used in industrial motor control panels and HVAC equipment
Bimetallic overload relay element for motor starters. Provides thermal protection by sensing motor current and tripping on overheat. Used in industrial motor control applications such as conveyors, pumps, and compressors
SQUARE
Bimetallic overload relay element for motor starters. Provides thermal protection by sensing motor current and tripping on overheat. Used in industrial motor control applications such as conveyors, pumps, and compressors
Overload relay heater element for motor protection. Bimetallic design trips within 20 seconds at 600% of rated current. Used with motor starters in industrial electrical panels to prevent damage from overcurrent conditions
SQUARE
Overload relay heater element for motor protection. Bimetallic design trips within 20 seconds at 600% of rated current. Used with motor starters in industrial electrical panels to prevent damage from overcurrent conditions