SQUARE D Molded Case Circuit Breaker: 80 A Amps, 25kA at 277/408V AC, Fixed, Everlink Lug Both Ends - B-Frame Square D Molded Case Circuit Breakers
SQUARE DB-Frame Square D Molded Case Circuit Breakers

SQUARE D Molded Case Circuit Breaker: 80 A Amps, 25kA at 277/408V AC, Fixed, Everlink Lug Both Ends

The Square D BDL26080 is a B-Frame Molded Case Circuit Breaker rated 80 A with a 25kA AIR at 277/408V AC. This 2-pole unit features fixed instantaneous trip and Everlink Lug connections on both ends, providing a…

SKU 3G-OTH-721981

Brand
SQUARE D
Item
Molded Case Circuit Breaker: 80 A Amps, 25kA at 277/408V AC, Fixed, Everlink Lug Both Ends
Category
B-Frame Square D Molded Case Circuit Breakers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

SQUARE D
Manufacturer Part Number
BDL26080
Series
BDL
Type
25kA at 277/408V AC, Fixed, Everlink Lug Both Ends
Poles
2
Max. AIR Rating
25kA at 277/408V AC
Phase Connection
Non-Applicable
Instantaneous Trip
Fixed
Terminal Connection
Everlink Lug Both Ends
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

SQUARE D Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Square D BDL26080 is a B-Frame Molded Case Circuit Breaker rated 80 A with a 25kA AIR at 277/408V AC. This 2-pole unit features fixed instantaneous trip and Everlink Lug connections on both ends, providing a reliable overcurrent protection solution for industrial electrical distribution.

Frequently Asked Questions

What is the Square D BDL26080 molded case circuit breaker used for?

The Square D BDL26080 provides overcurrent protection in industrial electrical distribution panels. It is a B-Frame, 2-pole breaker rated 80 A with a 25kA interrupting rating at 277/408V AC, suitable for branch circuits and feeder protection in manufacturing and process facilities.

What are the specifications of the Square D BDL26080 circuit breaker?

The Square D BDL26080 is a 2-pole, B-Frame molded case circuit breaker rated 80 A with a maximum AIR of 25kA at 277/408V AC. It features fixed instantaneous trip and Everlink Lug connections on both ends. The series is BDL, and the MPN is BDL26080.

Where to buy the Square D BDL26080 circuit breaker worldwide?

3G Electric supplies the Square D BDL26080 molded case circuit breaker to customers worldwide. As a global industrial sourcing partner, we handle logistics, customs clearance, and delivery to your site. Contact us for a quote and lead time on this 80 A, 2-pole breaker.

How to install the Square D BDL26080 circuit breaker?

Install the Square D BDL26080 by mounting it on a standard DIN rail or panel, then torque the Everlink Lug terminals to the manufacturer's specified value for 80 A conductors. Ensure the breaker is in the OFF position before wiring. Always follow local electrical codes and de-energize the panel before installation.

Used in

Common applications for SQUARE D
Commercial building electrical panels — Square D QO series plug-in circuit breakers for branch circuit protection
Industrial motor control centers — Square D QOB series bolt-on breakers in NQOD panelboards
Heating equipment installations — Square D QOU series unit-mount breakers for overcurrent protection
Outdoor electrical distribution — Square D L-Frame enclosures housing LAL/LHL breakers for 400 A service
Indoor facility power distribution — Square D Q-Frame enclosures with QBL/QDL breakers for 225 A circuits
Retrofit and replacement in existing Square D load centers — QO series breakers for 120/240V AC systems

SQUARE D Products

3G Electric supplies SQUARE D b-frame square d molded case circuit breakers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from SQUARE D

View all SQUARE D parts
Molded Case Circuit Breaker: 30 A Amps, 100kA at 120/240V AC, Fixed, Everlink Lug Both Ends, Any (MPN BJL16030). Key specifications — Terminal Connection: Everlink Lug Both Ends; Phase Connection: Any; Max. AIR Rating: 100kA at 120/240V AC; Instantaneous Trip: Fixed; Series: BJL.
SQUARE D
Molded Case Circuit Breaker: 30 A Amps, 100kA at 120/240V AC, Fixed, Everlink Lug Both Ends, Any (MPN BJL16030). Key specifications — Terminal Connection: Everlink Lug Both Ends; Phase Connection: Any; Max. AIR Rating: 100kA at 120/240V AC; Instantaneous Trip: Fixed; Series: BJL.
Molded Case Circuit Breaker: 50 A Amps, 25kA at 277/408V AC, Fixed, AB, 2 Poles, 525V AC, BDA (MPN BDA260501). Key specifications — Terminal Connection: I-Line ON End; Phase Connection: AB; Max. AIR Rating: 25kA at 277/408V AC; Instantaneous Trip: Fixed; Series: BDA.
SQUARE D
Molded Case Circuit Breaker: 50 A Amps, 25kA at 277/408V AC, Fixed, AB, 2 Poles, 525V AC, BDA (MPN BDA260501). Key specifications — Terminal Connection: I-Line ON End; Phase Connection: AB; Max. AIR Rating: 25kA at 277/408V AC; Instantaneous Trip: Fixed; Series: BDA.
Molded Case Circuit Breaker: 50 A Amps, 25kA at 277/408V AC, Fixed, Everlink Lug Both Ends, 2 Poles (MPN BDL26050LU). Key specifications — Terminal Connection: Everlink Lug Both Ends; Phase Connection: Non-Applicable; Max. AIR Rating: 25kA at 277/408V AC; Instantaneous Trip: Fixed; Series: BDL.
SQUARE D
Molded Case Circuit Breaker: 50 A Amps, 25kA at 277/408V AC, Fixed, Everlink Lug Both Ends, 2 Poles (MPN BDL26050LU). Key specifications — Terminal Connection: Everlink Lug Both Ends; Phase Connection: Non-Applicable; Max. AIR Rating: 25kA at 277/408V AC; Instantaneous Trip: Fixed; Series: BDL.
Molded Case Circuit Breaker: 100 A Amps, 25kA at 277/408V AC, Fixed, Everlink Lug Both Ends, ABC (MPN BDL36100). Key specifications — Terminal Connection: Everlink Lug Both Ends; Phase Connection: ABC; Max. AIR Rating: 25kA at 277/408V AC; Instantaneous Trip: Fixed; Series: BDL.
SQUARE D
Molded Case Circuit Breaker: 100 A Amps, 25kA at 277/408V AC, Fixed, Everlink Lug Both Ends, ABC (MPN BDL36100). Key specifications — Terminal Connection: Everlink Lug Both Ends; Phase Connection: ABC; Max. AIR Rating: 25kA at 277/408V AC; Instantaneous Trip: Fixed; Series: BDL.
Molded Case Circuit Breaker: 70 A Amps, 25kA at 277/408V AC, Fixed, AB, 2 Poles, 525V AC, BDA (MPN BDA260701). Key specifications — Terminal Connection: I-Line ON End; Phase Connection: AB; Max. AIR Rating: 25kA at 277/408V AC; Instantaneous Trip: Fixed; Series: BDA.
SQUARE D
Molded Case Circuit Breaker: 70 A Amps, 25kA at 277/408V AC, Fixed, AB, 2 Poles, 525V AC, BDA (MPN BDA260701). Key specifications — Terminal Connection: I-Line ON End; Phase Connection: AB; Max. AIR Rating: 25kA at 277/408V AC; Instantaneous Trip: Fixed; Series: BDA.
Molded Case Circuit Breaker: 45 A Amps, 100kA at 240V AC, Fixed, ABC, 3 Poles, 525V AC, BGA (MPN BGA34045Y). Key specifications — Terminal Connection: I-Line ON End; Phase Connection: ABC; Max. AIR Rating: 100kA at 240V AC; Instantaneous Trip: Fixed; Series: BGA.
SQUARE D
Molded Case Circuit Breaker: 45 A Amps, 100kA at 240V AC, Fixed, ABC, 3 Poles, 525V AC, BGA (MPN BGA34045Y). Key specifications — Terminal Connection: I-Line ON End; Phase Connection: ABC; Max. AIR Rating: 100kA at 240V AC; Instantaneous Trip: Fixed; Series: BGA.
Molded Case Circuit Breaker: 70 A Amps, 100kA at 120/240V AC, Fixed, Everlink Lug Both Ends, ABC (MPN BJL36070LU). Key specifications — Terminal Connection: Everlink Lug Both Ends; Phase Connection: ABC; Max. AIR Rating: 100kA at 120/240V AC; Instantaneous Trip: Fixed; Series: BJL.
SQUARE D
Molded Case Circuit Breaker: 70 A Amps, 100kA at 120/240V AC, Fixed, Everlink Lug Both Ends, ABC (MPN BJL36070LU). Key specifications — Terminal Connection: Everlink Lug Both Ends; Phase Connection: ABC; Max. AIR Rating: 100kA at 120/240V AC; Instantaneous Trip: Fixed; Series: BJL.
Molded Case Circuit Breaker: 35 A Amps, 100kA at 240V AC, Fixed, Everlink Lug Both Ends, ABC, BGL (MPN BGL36035). Key specifications — Terminal Connection: Everlink Lug Both Ends; Phase Connection: ABC; Max. AIR Rating: 100kA at 240V AC; Instantaneous Trip: Fixed; Series: BGL.
SQUARE D
Molded Case Circuit Breaker: 35 A Amps, 100kA at 240V AC, Fixed, Everlink Lug Both Ends, ABC, BGL (MPN BGL36035). Key specifications — Terminal Connection: Everlink Lug Both Ends; Phase Connection: ABC; Max. AIR Rating: 100kA at 240V AC; Instantaneous Trip: Fixed; Series: BGL.