SQUARE D 8536SBA2V06 Enclosed Non-Reversing Starter with Thermal Overloads - Enclosed Non-Reversing Starters with Thermal Overloads
SQUARE DEnclosed Non-Reversing Starters with Thermal Overloads

SQUARE D 8536SBA2V06 Enclosed Non-Reversing Starter with Thermal Overloads

The SQUARE D Magnetic Motor Starter is an enclosed non-reversing starter with thermal overloads, NEMA Size 0, 3 poles, 18 A, and a 480V AC coil (MPN 8536SBA2V06). It is a three-phase unit with screw clamp terminals…

SKU 3G-OTH-40570

Brand
SQUARE D
Item
8536SBA2V06 Enclosed Non-Reversing Starter with Thermal Overloads
Category
Enclosed Non-Reversing Starters with Thermal Overloads
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

SQUARE D
Manufacturer Part Number
8536SBA2V06
Type
NEMA Size 0, 18 A
Phase
Three
Poles
3
AC Coil
480V
Operator
None
Coil Voltage
480V AC
Operator Controls
None
Includes Pilot Light
No
Thermal Units Required
3 Melting Alloy Units (Not Included)
Terminal Connection Type
Screw Clamp Terminals
Auxiliary Contacts Included
No Auxiliary Contacts Included

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

SQUARE D Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The SQUARE D Magnetic Motor Starter is an enclosed non-reversing starter with thermal overloads, NEMA Size 0, 3 poles, 18 A, and a 480V AC coil (MPN 8536SBA2V06). It is a three-phase unit with screw clamp terminals, no operator, no operator controls, no pilot light, and no auxiliary contacts. Three melting alloy thermal units are required but not included.

Frequently Asked Questions

What is the SQUARE D 8536SBA2V06 magnetic motor starter used for?

The SQUARE D 8536SBA2V06 is an enclosed non-reversing magnetic motor starter with thermal overloads, designed to start and protect three-phase AC motors in industrial applications such as conveyors, pumps, and compressors. It provides reliable motor control and overload protection in a NEMA Size 0, 18 A rating.

What are the specifications of the SQUARE D 8536SBA2V06 starter?

The SQUARE D 8536SBA2V06 is a NEMA Size 0, 18 A, non-reversing starter with 3 poles, a 480V AC coil, and three-phase operation. It features screw clamp terminals, no operator or pilot light, and no auxiliary contacts. Three melting alloy thermal units are required but not included.

Where to buy the SQUARE D 8536SBA2V06 worldwide?

You can source the SQUARE D 8536SBA2V06 magnetic motor starter through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations. Contact us for availability and lead time.

How to select thermal units for the SQUARE D 8536SBA2V06 starter?

To select thermal units for the SQUARE D 8536SBA2V06, match the melting alloy heater element to the full-load current of your motor. SQUARE D provides selection tables based on motor horsepower and voltage. Install three units (one per phase) to enable proper overload protection. Consult the manufacturer's documentation for exact part numbers.

Used in

Common applications for SQUARE D
Commercial building electrical panels — Square D QO series plug-in circuit breakers for branch circuit protection
Industrial motor control centers — Square D QOB series bolt-on breakers in NQOD panelboards
Heating equipment installations — Square D QOU series unit-mount breakers for overcurrent protection
Outdoor electrical distribution — Square D L-Frame enclosures housing LAL/LHL breakers for 400 A service
Indoor facility power distribution — Square D Q-Frame enclosures with QBL/QDL breakers for 225 A circuits
Retrofit and replacement in existing Square D load centers — QO series breakers for 120/240V AC systems

SQUARE D Products

3G Electric supplies SQUARE D enclosed non-reversing starters with thermal overloads. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Non-reversing magnetic motor starter for single-phase motors. NEMA Size 00, 9 A, 2-pole, 120V AC coil. Screw clamp terminals. Requires one melting alloy thermal unit (not included). No operator, pilot light, or auxiliary contacts. Used for starting and protecting motors in applications such as conveyors, pumps, and fans
SQUARE D
Non-reversing magnetic motor starter for single-phase motors. NEMA Size 00, 9 A, 2-pole, 120V AC coil. Screw clamp terminals. Requires one melting alloy thermal unit (not included). No operator, pilot light, or auxiliary contacts. Used for starting and protecting motors in applications such as conveyors, pumps, and fans
Enclosed non-reversing magnetic motor starter for three-phase motors. NEMA Size 2, 45 A, 480V AC coil, 3 poles. Screw clamp terminals. Requires three melting alloy thermal units (not included). No operator, pilot light, or auxiliary contacts. Used for starting and stopping motors in applications such as conveyors, pumps, and compressors
SQUARE D
Enclosed non-reversing magnetic motor starter for three-phase motors. NEMA Size 2, 45 A, 480V AC coil, 3 poles. Screw clamp terminals. Requires three melting alloy thermal units (not included). No operator, pilot light, or auxiliary contacts. Used for starting and stopping motors in applications such as conveyors, pumps, and compressors
SQUARE D Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 3, 90 A, 208V AC Coil (MPN 8536SEA1V08)
SQUARE D
SQUARE D Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 3, 90 A, 208V AC Coil (MPN 8536SEA1V08)
SQUARE D Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 1, 27 A, 480V AC Coil (MPN 8536SCA3V06)
SQUARE D
SQUARE D Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 1, 27 A, 480V AC Coil (MPN 8536SCA3V06)
SQUARE D Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 00, 9 A, 480V AC Coil (MPN 8536SAG12V06)
SQUARE D
SQUARE D Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 00, 9 A, 480V AC Coil (MPN 8536SAG12V06)
SQUARE D Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 4, 135 A, 480V AC Coil (MPN 8536SFG1V06)
SQUARE D
SQUARE D Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 4, 135 A, 480V AC Coil (MPN 8536SFG1V06)

More from SQUARE D

View all SQUARE D parts
Enclosed non-reversing magnetic motor starter for three-phase motors. NEMA Size 3, 90 A, 3 poles, 208V AC coil. Screw clamp terminals. Requires three melting alloy thermal units (not included). No operator controls, pilot light, or auxiliary contacts
SQUARE D
Enclosed non-reversing magnetic motor starter for three-phase motors. NEMA Size 3, 90 A, 3 poles, 208V AC coil. Screw clamp terminals. Requires three melting alloy thermal units (not included). No operator controls, pilot light, or auxiliary contacts
Enclosed non-reversing magnetic motor starter for starting and protecting three-phase motors. NEMA Size 3 rated at 90 A with three poles and a 480V AC coil. Requires three melting alloy thermal units (not included) for overload protection. Features screw clamp terminals; no operator controls, pilot light, or auxiliary contacts included
SQUARE D
Enclosed non-reversing magnetic motor starter for starting and protecting three-phase motors. NEMA Size 3 rated at 90 A with three poles and a 480V AC coil. Requires three melting alloy thermal units (not included) for overload protection. Features screw clamp terminals; no operator controls, pilot light, or auxiliary contacts included
Enclosed non-reversing manual motor starter with thermal overload protection. Rated 16 A, 2 poles, operated by a toggle switch. Requires one thermal unit (not included). Suitable for on/off control and protection of single-phase or two-phase motors in applications such as pumps, conveyors, and machine tools
SQUARE D
Enclosed non-reversing manual motor starter with thermal overload protection. Rated 16 A, 2 poles, operated by a toggle switch. Requires one thermal unit (not included). Suitable for on/off control and protection of single-phase or two-phase motors in applications such as pumps, conveyors, and machine tools
This enclosed non-reversing starter is designed for single-phase motor control in applications such as pumps, conveyors, and fans. It features a NEMA Size 0, 18 A rating, 2 poles, and a 110/120V AC coil. Screw clamp terminals are provided for wiring; one melting alloy thermal unit (not included) is required for overload protection. No operator controls, auxiliary contacts, or pilot light are included
SQUARE D
This enclosed non-reversing starter is designed for single-phase motor control in applications such as pumps, conveyors, and fans. It features a NEMA Size 0, 18 A rating, 2 poles, and a 110/120V AC coil. Screw clamp terminals are provided for wiring; one melting alloy thermal unit (not included) is required for overload protection. No operator controls, auxiliary contacts, or pilot light are included
Enclosed non-reversing magnetic motor starter for three-phase motors. NEMA Size 2, 45 A, 3 poles, 220/240V AC coil. Screw clamp terminals. Requires three melting alloy thermal units (not included). Suitable for starting and protecting motors in applications such as conveyors, pumps, and compressors
SQUARE D
Enclosed non-reversing magnetic motor starter for three-phase motors. NEMA Size 2, 45 A, 3 poles, 220/240V AC coil. Screw clamp terminals. Requires three melting alloy thermal units (not included). Suitable for starting and protecting motors in applications such as conveyors, pumps, and compressors
Enclosed non-reversing manual motor starter with thermal overload protection. Features 2 poles, 16 A rating, and toggle switch actuator. Requires one thermal unit (not included) for overload protection. Suitable for starting and stopping single-speed motors in applications such as conveyors, pumps, and fans
SQUARE D
Enclosed non-reversing manual motor starter with thermal overload protection. Features 2 poles, 16 A rating, and toggle switch actuator. Requires one thermal unit (not included) for overload protection. Suitable for starting and stopping single-speed motors in applications such as conveyors, pumps, and fans
Enclosed non-reversing manual motor starter with thermal overload protection. Rated 27 A, 2 poles, 600V AC maximum, NEMA Size M-1. Requires one thermal unit (not included). Suitable for starting and stopping motors in applications such as conveyors, pumps, and fans
SQUARE D
Enclosed non-reversing manual motor starter with thermal overload protection. Rated 27 A, 2 poles, 600V AC maximum, NEMA Size M-1. Requires one thermal unit (not included). Suitable for starting and stopping motors in applications such as conveyors, pumps, and fans
This enclosed non-reversing magnetic motor starter from SQUARE D is designed for starting and protecting 3-phase motors in industrial equipment such as conveyors, pumps, and fans. It features 3 poles, a 20 A rating, and a 480V AC coil. Three thermal units are required but not included for overload protection
SQUARE D
This enclosed non-reversing magnetic motor starter from SQUARE D is designed for starting and protecting 3-phase motors in industrial equipment such as conveyors, pumps, and fans. It features 3 poles, a 20 A rating, and a 480V AC coil. Three thermal units are required but not included for overload protection