SQUARE D 8536SCG2V02 Enclosed Non-Reversing Starter with Thermal Overloads - Enclosed Non-Reversing Starters with Thermal Overloads
SQUARE DEnclosed Non-Reversing Starters with Thermal Overloads

SQUARE D 8536SCG2V02 Enclosed Non-Reversing Starter with Thermal Overloads

The SQUARE D Magnetic Motor Starter is an enclosed non-reversing starter with thermal overloads, NEMA Size 1P, 2 poles, 36 A, and a 110/120V AC coil (MPN 8536SCG2V02). It is a single-phase unit with screw clamp…

SKU 3G-OTH-40746

Brand
SQUARE D
Item
8536SCG2V02 Enclosed Non-Reversing Starter with Thermal Overloads
Part Number
8536SCG2V02
Category
Enclosed Non-Reversing Starters with Thermal Overloads
Available to Order
Also known as:8536SCG2V02SQUARE D
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

SQUARE D
Manufacturer Part Number
8536SCG2V02
Type
NEMA Size 1P, 36 A
Phase
Single
Poles
2
AC Coil
120V
Operator
None
Coil Voltage
110/120V AC
Operator Controls
None
Includes Pilot Light
No
Thermal Units Required
1 Melting Alloy Unit (Not Included)
Terminal Connection Type
Screw Clamp Terminals
Auxiliary Contacts Included
No Auxiliary Contacts Included

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

SQUARE D Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The SQUARE D Magnetic Motor Starter is an enclosed non-reversing starter with thermal overloads, NEMA Size 1P, 2 poles, 36 A, and a 110/120V AC coil (MPN 8536SCG2V02). It is a single-phase unit with screw clamp terminals, no operator controls, no pilot light, and no auxiliary contacts. One melting alloy thermal unit (not included) is required for overload protection.

Frequently Asked Questions

What is the SQUARE D 8536SCG2V02 magnetic motor starter used for?

The SQUARE D 8536SCG2V02 is an enclosed non-reversing magnetic motor starter used to start and stop single-phase motors in industrial applications such as conveyors, pumps, and fans. It provides overload protection via a melting alloy thermal unit (sold separately) and is suitable for NEMA Size 1P installations.

What are the specifications of the SQUARE D 8536SCG2V02 magnetic motor starter?

The SQUARE D 8536SCG2V02 is a NEMA Size 1P, 2-pole, 36 A, single-phase magnetic motor starter with a 110/120V AC coil. It features screw clamp terminals, no operator controls, no pilot light, and no auxiliary contacts. One melting alloy thermal unit (not included) is required for overload protection.

Where to buy the SQUARE D 8536SCG2V02 magnetic motor starter worldwide?

3G Electric supplies the SQUARE D 8536SCG2V02 magnetic motor starter worldwide. As a global industrial equipment distributor established in 1990, we handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time.

How to select the correct thermal unit for the SQUARE D 8536SCG2V02 starter?

To select the correct melting alloy thermal unit for the SQUARE D 8536SCG2V02, match the motor full-load current to the SQUARE D thermal unit selection chart. The starter requires one thermal unit (not included) for overload protection. Consult the SQUARE D catalog or contact 3G Electric for guidance.

Used in

Common applications for SQUARE D
Commercial electrical panels — QO and QOB miniature circuit breakers for overcurrent protection in load centers and panelboards.
HVACR equipment — 8910 Series Type DPA definite purpose contactors for switching compressor and fan motor loads.
Industrial power distribution — J-Frame molded case circuit breakers for main and feeder protection in switchboards.
Residential ground-fault protection — QO and QOB GFI circuit breakers for kitchens, bathrooms, and outdoor circuits.
Motor control centers — definite purpose contactors for controlling pumps, fans, and other moderate motor loads.
OEM machinery — Square D circuit breakers and contactors for integration into control panels and equipment.
Not sure this is the right part? Photo-identify it→

SQUARE D Products

3G Electric supplies SQUARE D enclosed non-reversing starters with thermal overloads. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

More from SQUARE D

View all SQUARE D parts →
Enclosed non-reversing magnetic motor starter with thermal overload protection. Rated 30 A, 2 poles, 120V AC coil. Requires one thermal unit (not included) for overload protection. Suitable for controlling single-speed motors in applications such as HVAC, pumps, and conveyors
SQUARE D
Enclosed non-reversing magnetic motor starter with thermal overload protection. Rated 30 A, 2 poles, 120V AC coil. Requires one thermal unit (not included) for overload protection. Suitable for controlling single-speed motors in applications such as HVAC, pumps, and conveyors

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first