SQUARE D 8911DPSO42V09 Non-Reversing Starter with Thermal Overloads - Non-Reversing Starters with Thermal Overloads
SQUARE DNon-Reversing Starters with Thermal Overloads

SQUARE D 8911DPSO42V09 Non-Reversing Starter with Thermal Overloads

The SQUARE D Definite Purpose Magnetic Motor Starter is a non-reversing starter with thermal overloads, designed for industrial motor control. This 2-pole, 40 A unit operates with a 208-240V AC coil (MPN…

SKU 3G-OTH-42001

Brand
SQUARE D
Item
8911DPSO42V09 Non-Reversing Starter with Thermal Overloads
Part Number
8911DPSO42V09
Category
Non-Reversing Starters with Thermal Overloads
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Payment
Invoicing in SGD. Bank transfer and corporate PO accepted.

Technical Specifications

SQUARE D
Manufacturer Part Number
8911DPSO42V09
Type
40 A
Poles
2
AC Coil
208-240V
Thermal Units Required
1 Thermal Unit Required (Not Included)

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.
Ask a question

Ask a question

SQUARE D Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The SQUARE D Definite Purpose Magnetic Motor Starter is a non-reversing starter with thermal overloads, designed for industrial motor control. This 2-pole, 40 A unit operates with a 208-240V AC coil (MPN 8911DPSO42V09). It requires one thermal unit (not included) for overload protection.

Frequently Asked Questions

What is the SQUARE D 8911DPSO42V09 definite purpose magnetic motor starter used for?

The SQUARE D 8911DPSO42V09 is a non-reversing definite purpose magnetic motor starter with thermal overloads, used for starting and stopping industrial motors such as fans, pumps, and compressors. It provides overload protection when a thermal unit is installed, making it suitable for HVAC and light manufacturing applications.

What are the specifications of the SQUARE D 8911DPSO42V09 motor starter?

The SQUARE D 8911DPSO42V09 is a 2-pole, 40 A non-reversing definite purpose magnetic motor starter with a 208-240V AC coil. It requires one thermal unit (not included) for overload protection. The manufacturer part number is 8911DPSO42V09, and it is designed for industrial motor control applications.

Where to buy the SQUARE D 8911DPSO42V09 motor starter worldwide?

You can source the SQUARE D 8911DPSO42V09 definite purpose magnetic motor starter through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations. Contact us for availability and lead time on this SQUARE D part.

How to select the correct thermal unit for the SQUARE D 8911DPSO42V09 starter?

To select the correct thermal unit for the SQUARE D 8911DPSO42V09 starter, match the thermal unit's current rating to the full-load amperage of your motor. The starter requires one thermal unit (not included) for overload protection. Consult the motor nameplate and SQUARE D thermal unit selection charts to ensure proper sizing and avoid nuisance tripping.

Used in

Common applications for SQUARE D
Commercial electrical panels — QO and QOB miniature circuit breakers for overcurrent protection in load centers and panelboards.
HVACR equipment — 8910 Series Type DPA definite purpose contactors for switching compressor and fan motor loads.
Industrial power distribution — J-Frame molded case circuit breakers for main and feeder protection in switchboards.
Residential ground-fault protection — QO and QOB GFI circuit breakers for kitchens, bathrooms, and outdoor circuits.
Motor control centers — definite purpose contactors for controlling pumps, fans, and other moderate motor loads.
OEM machinery — Square D circuit breakers and contactors for integration into control panels and equipment.
Not sure this is the right part? Photo-identify it→

SQUARE D Products

3G Electric supplies SQUARE D non-reversing starters with thermal overloads. We supply genuine products and their technical documentation.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

Compatible alternatives & equivalents

Cross-referenced by specification & description
Non-reversing magnetic motor starter with thermal overloads, rated 30 A, 3 poles, and 208-240V AC coil. Requires three thermal units (sold separately) for overload protection. Suitable for starting and protecting 3-phase motors in applications such as HVAC, pumps, and conveyors
SQUARE D
Non-reversing magnetic motor starter with thermal overloads, rated 30 A, 3 poles, and 208-240V AC coil. Requires three thermal units (sold separately) for overload protection. Suitable for starting and protecting 3-phase motors in applications such as HVAC, pumps, and conveyors
Enclosed non-reversing magnetic motor starter with thermal overload protection. Rated 40 A, 2 poles, with a 208-240V AC coil. One thermal unit required (not included). Suitable for starting and stopping motors in applications such as HVAC, pumps, and conveyors
SQUARE D
Enclosed non-reversing magnetic motor starter with thermal overload protection. Rated 40 A, 2 poles, with a 208-240V AC coil. One thermal unit required (not included). Suitable for starting and stopping motors in applications such as HVAC, pumps, and conveyors
Enclosed non-reversing magnetic motor starter with thermal overload protection. Rated 40 A, 2 poles, 120V AC coil. Requires one thermal unit (not included). Suitable for controlling and protecting motors in applications such as HVAC, refrigeration, and industrial equipment
SQUARE D
Enclosed non-reversing magnetic motor starter with thermal overload protection. Rated 40 A, 2 poles, 120V AC coil. Requires one thermal unit (not included). Suitable for controlling and protecting motors in applications such as HVAC, refrigeration, and industrial equipment

More from SQUARE D

View all SQUARE D parts →
This NEMA Size 0 non-reversing starter is designed for three-phase motor control applications such as conveyors, pumps, and compressors. It features a 480V AC coil, 18 A rating, three poles, and screw clamp terminals. Three melting alloy thermal units (not included) are required for overload protection. No operator controls, pilot light, or auxiliary contacts are included
SQUARE D
This NEMA Size 0 non-reversing starter is designed for three-phase motor control applications such as conveyors, pumps, and compressors. It features a 480V AC coil, 18 A rating, three poles, and screw clamp terminals. Three melting alloy thermal units (not included) are required for overload protection. No operator controls, pilot light, or auxiliary contacts are included
Three-pole non-reversing magnetic motor starter with thermal overload protection. NEMA Size 0 rated 18 A, 110/120V AC coil, screw clamp terminals. Requires three melting alloy thermal units (not included). Used for starting and stopping three-phase motors in industrial applications
SQUARE D
Three-pole non-reversing magnetic motor starter with thermal overload protection. NEMA Size 0 rated 18 A, 110/120V AC coil, screw clamp terminals. Requires three melting alloy thermal units (not included). Used for starting and stopping three-phase motors in industrial applications
Non-reversing magnetic motor starter with thermal overload protection for three-phase motors. Three-pole design rated for 30 A with a 120V AC coil. Requires three thermal units (not included) for overload protection. Suitable for controlling motors in industrial equipment such as conveyors, pumps, and fans
SQUARE D
Non-reversing magnetic motor starter with thermal overload protection for three-phase motors. Three-pole design rated for 30 A with a 120V AC coil. Requires three thermal units (not included) for overload protection. Suitable for controlling motors in industrial equipment such as conveyors, pumps, and fans
This non-reversing magnetic motor starter from SQUARE D is rated for 40 A and features a 24V AC coil. It has 3 poles and requires 3 thermal units (not included) for overload protection. Suitable for starting and protecting motors in HVAC, pumps, and industrial machinery
SQUARE D
This non-reversing magnetic motor starter from SQUARE D is rated for 40 A and features a 24V AC coil. It has 3 poles and requires 3 thermal units (not included) for overload protection. Suitable for starting and protecting motors in HVAC, pumps, and industrial machinery
Non-reversing manual motor starter with thermal overload protection for single-pole applications up to 16 A. Features a toggle switch for manual on/off control. Requires one thermal unit (not included) for overload protection. Suitable for controlling and protecting small motors in industrial equipment, conveyors, and pumps
SQUARE D
Non-reversing manual motor starter with thermal overload protection for single-pole applications up to 16 A. Features a toggle switch for manual on/off control. Requires one thermal unit (not included) for overload protection. Suitable for controlling and protecting small motors in industrial equipment, conveyors, and pumps
Non-reversing magnetic motor starter for three-phase motors. NEMA Size 2, 45 A, 3 poles, 24V AC coil. Screw clamp terminals. Requires three melting alloy thermal units (not included). Suitable for starting and stopping motors in applications such as conveyors, pumps, and compressors
SQUARE D
Non-reversing magnetic motor starter for three-phase motors. NEMA Size 2, 45 A, 3 poles, 24V AC coil. Screw clamp terminals. Requires three melting alloy thermal units (not included). Suitable for starting and stopping motors in applications such as conveyors, pumps, and compressors
Three-pole non-reversing motor starter with thermal overload protection. NEMA Size 2 rated 45 A, 220/240V AC coil. Screw clamp terminals. Requires three melting alloy thermal units (not included). Suitable for starting and protecting three-phase motors in industrial machinery
SQUARE D
Three-pole non-reversing motor starter with thermal overload protection. NEMA Size 2 rated 45 A, 220/240V AC coil. Screw clamp terminals. Requires three melting alloy thermal units (not included). Suitable for starting and protecting three-phase motors in industrial machinery
Non-reversing magnetic motor starter with thermal overload protection for three-phase motors. Rated 25 A, 3 poles, with a 208-240V AC coil. Requires three thermal units (not included). Suitable for starting and protecting motors in applications such as conveyors, pumps, and fans
SQUARE D
Non-reversing magnetic motor starter with thermal overload protection for three-phase motors. Rated 25 A, 3 poles, with a 208-240V AC coil. Requires three thermal units (not included). Suitable for starting and protecting motors in applications such as conveyors, pumps, and fans