The TRACXP TXP-T40-NO2-PPM-EC is a wall-mounted fixed gas detector for nitrogen dioxide, with a measurement range of 0 to 20 ppm. It operates on 10 to 30V DC and features a digital display, designed for use with any…

SKU 3G-OTH-552543

Also listed as: TXPT40NO2PPMEC · TXP T40 NO2 PPM EC

Brand
TRACXP
Item
Explosion Proof Gas Detector: Any 4-20mA Control/DVP-120 Control
Category
Fixed Gas Detectors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

TRACXP
Manufacturer Part Number
TXP-T40-NO2-PPM-EC
Series
TXP-T40
Type
Control Panel/TXP-T40 Control Panel
Voltage
Low Voltage (12 to 24V AC, 12 to 32V DC)
Display Type
Digital
For Use With
Any 4-20mA Control
Gas Detected
Nitrogen Dioxide
Product Type
Fixed Gas Detector
Measurement Range
Nitrogen Dioxide (0 to 20 ppm)
Mounting Location
Wall
Operating Voltage
10 to 30V DC

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

TRACXP Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The TRACXP TXP-T40-NO2-PPM-EC is a wall-mounted fixed gas detector for nitrogen dioxide, with a measurement range of 0 to 20 ppm. It operates on 10 to 30V DC and features a digital display, designed for use with any 4-20mA control system.

Frequently Asked Questions

What is the TRACXP TXP-T40-NO2-PPM-EC used for?

The TRACXP TXP-T40-NO2-PPM-EC is a wall-mounted fixed gas detector that continuously monitors nitrogen dioxide levels from 0 to 20 ppm. It is used in industrial environments such as chemical plants, refineries, and wastewater facilities to alert personnel to hazardous NO2 concentrations.

What are the specifications of the TRACXP TXP-T40-NO2-PPM-EC?

The TRACXP TXP-T40-NO2-PPM-EC is a fixed gas detector with a digital display, operating on 10 to 30V DC. It detects nitrogen dioxide over a 0 to 20 ppm range and is designed for wall mounting. It works with any 4-20mA control panel.

Where to buy the TRACXP TXP-T40-NO2-PPM-EC worldwide?

3G Electric supplies the TRACXP TXP-T40-NO2-PPM-EC to customers worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this fixed gas detector.

How to install the TRACXP TXP-T40-NO2-PPM-EC?

Mount the TRACXP TXP-T40-NO2-PPM-EC on a wall at the height recommended for nitrogen dioxide detection. Connect the 4-20mA output to your control panel and supply 10 to 30V DC power. Follow the manufacturer's manual for wiring and calibration procedures.

TRACXP Products

3G Electric supplies TRACXP fixed gas detectors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from TRACXP

View all TRACXP parts
TRACXP Explosion Proof Gas Detector: Any 4-20mA Control/DVP-120 Control Panel/TXP-T40 Control Panel (MPN TXP-T40-C3H8-LEL-IR)
TRACXP
TRACXP Explosion Proof Gas Detector: Any 4-20mA Control/DVP-120 Control Panel/TXP-T40 Control Panel (MPN TXP-T40-C3H8-LEL-IR)
TRACXP Explosion Proof Gas Detector: Any 4-20mA Control/DVP-120 Control Panel/TXP-T40 Control Panel (MPN TXP-T40-CH4-LEL-CB)
TRACXP
TRACXP Explosion Proof Gas Detector: Any 4-20mA Control/DVP-120 Control Panel/TXP-T40 Control Panel (MPN TXP-T40-CH4-LEL-CB)
TRACXP Explosion Proof Gas Detector: Any 4-20mA Control/DVP-120 Control Panel/TXP-T40 Control Panel (MPN TXP-T40-CL2-PPM-EC)
TRACXP
TRACXP Explosion Proof Gas Detector: Any 4-20mA Control/DVP-120 Control Panel/TXP-T40 Control Panel (MPN TXP-T40-CL2-PPM-EC)
TRACXP Explosion Proof Gas Detector: Any 4-20mA Control/DVP-120 Control Panel/TXP-T40 Control Panel (MPN TXP-T40-NH3-PPM-EC)
TRACXP
TRACXP Explosion Proof Gas Detector: Any 4-20mA Control/DVP-120 Control Panel/TXP-T40 Control Panel (MPN TXP-T40-NH3-PPM-EC)
TRACXP Explosion Proof Gas Detector: Any 4-20mA Control/DVP-120 Control Panel/TXP-T40 Control Panel (MPN TXP-T40-SO2-PPM-EC)
TRACXP
TRACXP Explosion Proof Gas Detector: Any 4-20mA Control/DVP-120 Control Panel/TXP-T40 Control Panel (MPN TXP-T40-SO2-PPM-EC)
TRACXP Explosion Proof Gas Detector: Any 4-20mA Control/DVP-120 Control Panel/TXP-T40 Control Panel (MPN TXP-T40-CO2-VOL-IR)
TRACXP
TRACXP Explosion Proof Gas Detector: Any 4-20mA Control/DVP-120 Control Panel/TXP-T40 Control Panel (MPN TXP-T40-CO2-VOL-IR)
TRACXP Explosion Proof Gas Detector: Any 4-20mA Control/DVP-120 Control Panel/TXP-T40 Control Panel (MPN TXP-T40-CH4-LEL-IR)
TRACXP
TRACXP Explosion Proof Gas Detector: Any 4-20mA Control/DVP-120 Control Panel/TXP-T40 Control Panel (MPN TXP-T40-CH4-LEL-IR)
TRACXP Explosion Proof Gas Detector: Any 4-20mA Control/DVP-120 Control Panel/TXP-T40 Control Panel (MPN TXP-T40-H2-PPM-EC)
TRACXP
TRACXP Explosion Proof Gas Detector: Any 4-20mA Control/DVP-120 Control Panel/TXP-T40 Control Panel (MPN TXP-T40-H2-PPM-EC)