VICKERS CS-03-B50 Adjustable Pressure Relief Valve

The VICKERS CS-03-B50 is an adjustable pressure relief valve with a cast iron body, offering a maximum pressure of 1,000 psi, a minimum pressure of 125 psi, and a maximum flow rate of 45 gpm. This VICKERS valve…

SKU 3G-OTH-171241

Also listed as: CS03B50 · CS 03 B50

Brand
VICKERS
Item
CS-03-B50 Adjustable Pressure Relief Valve
Part Number
CS-03-B50
Category
Adjustable Pressure Relief Valves
Available to Order
Also known as:CS-03-B50VICKERS
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.

Technical Specifications

VICKERS
Manufacturer Part Number
CS-03-B50
Pressure
125 psi Min
Body Material
Cast Iron
Max Flow Rate
45 gpm

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

VICKERS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The VICKERS CS-03-B50 is an adjustable pressure relief valve with a cast iron body, offering a maximum pressure of 1,000 psi, a minimum pressure of 125 psi, and a maximum flow rate of 45 gpm. This VICKERS valve provides adjustable relief for hydraulic systems requiring precise pressure control within these specified parameters.

Frequently Asked Questions

What is the VICKERS CS-03-B50 adjustable relief valve used for?

The VICKERS CS-03-B50 is used in hydraulic systems to limit pressure by diverting flow when a set point is exceeded. It is suitable for industrial machinery, mobile equipment, and process lines requiring adjustable relief between 125 psi and 1,000 psi at up to 45 gpm.

What are the specifications of the VICKERS CS-03-B50?

The VICKERS CS-03-B50 adjustable relief valve has a cast iron body, a maximum pressure of 1,000 psi, a minimum pressure of 125 psi, and a maximum flow rate of 45 gpm. It is designed for hydraulic systems needing precise pressure control within these parameters.

Where to buy the VICKERS CS-03-B50 worldwide?

3G Electric supplies the VICKERS CS-03-B50 adjustable relief valve to customers worldwide. We handle full logistics, customs clearance, and delivery to your site. Contact us for a quote and lead time on this VICKERS hydraulic component.

How to install the VICKERS CS-03-B50 relief valve?

Install the VICKERS CS-03-B50 in the hydraulic line with proper port alignment. Adjust the set pressure using the adjustment screw while monitoring a gauge. Follow standard hydraulic safety practices: depressurize the system before installation and verify settings under operating conditions.

Used in

Common applications for VICKERS
Industrial manufacturing — Vickers J Series hydraulic motor (MPN 129-0293) for driving conveyor belts in assembly lines.
Material handling — Vickers J Series hydraulic motor (MPN 129-0342) for powering rotary feeders and index tables.
Process industries — Vickers J Series hydraulic motor (MPN 129-0458) for mixer and agitator drives in chemical processing.
Energy sector — Vickers J Series hydraulic motor (MPN 129-0339) for fan drives in cooling towers and air-cooled heat exchangers.
Mobile equipment — Vickers J Series hydraulic motor (MPN 129-0340) for auxiliary drive systems on off-highway machinery.
Food and beverage — Vickers J Series hydraulic motor (MPN 129-0291) for pump drives in clean-in-place systems.
Not sure this is the right part? Photo-identify it→

VICKERS Products

3G Electric supplies VICKERS adjustable pressure relief valves. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

Compatible alternatives & equivalents

Cross-referenced by specification & description
The ENERPAC V152 is an adjustable pressure relief valve with a steel body, designed for hydraulic systems requiring overpressure protection. It has a minimum pressure setting of 800 psi and a maximum flow rate of 4 gpm. Typical applications include industrial presses, jacks, and clamping systems where precise pressure control is needed
ENERPAC
The ENERPAC V152 is an adjustable pressure relief valve with a steel body, designed for hydraulic systems requiring overpressure protection. It has a minimum pressure setting of 800 psi and a maximum flow rate of 4 gpm. Typical applications include industrial presses, jacks, and clamping systems where precise pressure control is needed
This vacuum relief valve is designed for use with regenerative blowers to protect against excessive vacuum conditions. It features a 3 in NPT inlet and opens at a preset limit of 8 in Hg to prevent system damage
CONTROL DEVICES
This vacuum relief valve is designed for use with regenerative blowers to protect against excessive vacuum conditions. It features a 3 in NPT inlet and opens at a preset limit of 8 in Hg to prevent system damage
This pressure and vacuum relief valve is designed for use with regenerative blowers. It has a preset limit of 100 psi and a 1/4 in NPT inlet size. The valve vents excess pressure to protect blower systems in pneumatic applications
CONTROL DEVICES
This pressure and vacuum relief valve is designed for use with regenerative blowers. It has a preset limit of 100 psi and a 1/4 in NPT inlet size. The valve vents excess pressure to protect blower systems in pneumatic applications

More from VICKERS

View all VICKERS parts →

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first