Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

VICTOR Flow Gauge Regulator - Flow Gauge Regulators
VICTORFlow Gauge Regulators

VICTOR Flow Gauge Regulator

The VICTOR 0781-3641 is a flow gauge regulator with a CGA 580 inlet and a 5/8"-18 F RH outlet, designed for use with argon gas. It offers a flow capacity of 80 scfh for argon and 80 scfh for carbon dioxide.

SKU 3G-OTH-355702

Also listed as: 07813641 · 0781 3641

Brand
VICTOR
Item
Flow Gauge Regulator
Category
Flow Gauge Regulators
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

VICTOR
Manufacturer Part Number
0781-3641
Type
80 scfh (Argon) /80 scfh (Carbon Dioxide)
F RH Outlet
5/8"-18
Inlet Connection
CGA 580
Outlet Connection
5/8"-18 F RH
Compatible Gas Type
Argon

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

VICTOR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The VICTOR 0781-3641 is a flow gauge regulator with a CGA 580 inlet and a 5/8"-18 F RH outlet, designed for use with argon gas. It offers a flow capacity of 80 scfh for argon and 80 scfh for carbon dioxide.

Frequently Asked Questions

What is the VICTOR 0781-3641 gas regulator used for?

The VICTOR 0781-3641 flow gauge regulator is used to control and measure the flow of argon gas in welding and industrial applications. It is also compatible with carbon dioxide, delivering up to 80 scfh for each gas. This regulator is commonly employed in MIG welding and shielding gas systems.

What are the specifications of the VICTOR 0781-3641 regulator?

The VICTOR 0781-3641 regulator features a CGA 580 inlet and a 5/8"-18 F RH outlet. It is designed for argon gas and offers a flow capacity of 80 scfh for argon and 80 scfh for carbon dioxide. The manufacturer part number is 0781-3641, and it is a flow gauge regulator type.

Where to buy the VICTOR 0781-3641 regulator worldwide?

You can source the VICTOR 0781-3641 regulator through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations. Contact us for availability and lead time; we provide this VICTOR flow gauge regulator to customers internationally.

How to install the VICTOR 0781-3641 gas regulator?

To install the VICTOR 0781-3641 regulator, first ensure the cylinder valve is closed. Connect the CGA 580 inlet to the argon cylinder hand-tight, then tighten with a wrench. Attach the 5/8"-18 F RH outlet to your hose or equipment. Open the cylinder valve slowly and check for leaks using soapy water before use.

Used in

Common applications for VICTOR
Metal fabrication shops — VICTOR 1-GPP Series cutting tips for propylene-fueled handheld torch cutting of steel plate.
Pipeline maintenance — VICTOR single-stage fuel gas regulator (MPN 0781-0589) for controlling propane supply to heating nozzles.
Industrial heating applications — VICTOR MFN Series heating nozzle (MPN 0323-0304) for preheating metal before welding or bending.
Gas distribution systems — VICTOR flashback arrestor set (MPN 0656-0001) installed on torch handles to prevent flashback in oxygen-fuel setups.
Carbon dioxide shielding gas systems — VICTOR single-stage regulator (MPN 0781-3615) for regulating CO2 flow in welding operations.
Scrap metal cutting — VICTOR 55 Series heating nozzle (MPN 0323-0326) used with propane for heavy-duty heating and cutting applications.

VICTOR Products

3G Electric supplies VICTOR flow gauge regulators. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
This VICTOR flowmeter regulator is designed for use with argon gas. It features a CGA 580 inlet connection and a 5/8"-18 female right-hand outlet. The unit combines pressure regulation with a flowmeter to provide controlled gas delivery for welding and industrial processes
VICTOR
This VICTOR flowmeter regulator is designed for use with argon gas. It features a CGA 580 inlet connection and a 5/8"-18 female right-hand outlet. The unit combines pressure regulation with a flowmeter to provide controlled gas delivery for welding and industrial processes
This VICTOR flowmeter regulator is designed for use with Nitrogen gas. It features a CGA 580 inlet connection and a 5/8"-18 female right-hand outlet, with a flow capacity of 60 scfh. Commonly used in welding, heat treating, and laboratory gas supply applications to precisely control and measure gas flow
VICTOR
This VICTOR flowmeter regulator is designed for use with Nitrogen gas. It features a CGA 580 inlet connection and a 5/8"-18 female right-hand outlet, with a flow capacity of 60 scfh. Commonly used in welding, heat treating, and laboratory gas supply applications to precisely control and measure gas flow
This VICTOR flowmeter regulator combines pressure regulation and flow measurement for carbon dioxide gas. It features a CGA 580 inlet connection and a 5/8"-18 female right-hand outlet. Suitable for use in welding and other industrial gas applications where precise CO2 flow control is required
VICTOR
This VICTOR flowmeter regulator combines pressure regulation and flow measurement for carbon dioxide gas. It features a CGA 580 inlet connection and a 5/8"-18 female right-hand outlet. Suitable for use in welding and other industrial gas applications where precise CO2 flow control is required
This single-stage regulator reduces and controls pressure of air and inert gases from a cylinder. It features a CGA 580 inlet, 5/8"-15 F RH outlet, neoprene diaphragm, and a maximum inlet pressure rating of 150 psig. Commonly used in welding, cutting, and industrial gas distribution systems
VICTOR
This single-stage regulator reduces and controls pressure of air and inert gases from a cylinder. It features a CGA 580 inlet, 5/8"-15 F RH outlet, neoprene diaphragm, and a maximum inlet pressure rating of 150 psig. Commonly used in welding, cutting, and industrial gas distribution systems
Two-stage regulator for air and inert gases. Inlet connection: CGA 580. Outlet connection: 5/8"-18 F RH. Stainless steel diaphragm. Used in welding, cutting, and laboratory gas supply systems to reduce and stabilize pressure
VICTOR
Two-stage regulator for air and inert gases. Inlet connection: CGA 580. Outlet connection: 5/8"-18 F RH. Stainless steel diaphragm. Used in welding, cutting, and laboratory gas supply systems to reduce and stabilize pressure
Flowmeter regulator for carbon dioxide with CGA 320 inlet and 5/8"-18 female right-hand outlet. Used to control and measure CO2 flow from a cylinder in welding, beverage dispensing, and industrial gas applications
VICTOR
Flowmeter regulator for carbon dioxide with CGA 320 inlet and 5/8"-18 female right-hand outlet. Used to control and measure CO2 flow from a cylinder in welding, beverage dispensing, and industrial gas applications

More from VICTOR

View all VICTOR parts
VICTOR
VICTOR
Flow gauge regulator for Carbon Dioxide with CGA 320 inlet and 5/8"-18 female right-hand outlet. Provides 50 scfh flow capacity for both Carbon Dioxide and Argon. Used to control and measure gas flow from cylinders in welding and industrial gas systems
This flow gauge regulator from VICTOR is designed for use with Carbon Dioxide gas. It features a CGA 580 inlet connection and a 5/8"-18 female right-hand outlet, with flow capacities of 50 scfh for Argon and 38 scfh for Carbon Dioxide. Commonly used in welding and industrial gas applications to control and measure gas flow from a cylinder
VICTOR
This flow gauge regulator from VICTOR is designed for use with Carbon Dioxide gas. It features a CGA 580 inlet connection and a 5/8"-18 female right-hand outlet, with flow capacities of 50 scfh for Argon and 38 scfh for Carbon Dioxide. Commonly used in welding and industrial gas applications to control and measure gas flow from a cylinder
VICTOR Gas Regulator: CGA 320 Inlet, 5/8"-18 F RH Outlet, 80 scfh (Argon) /80 scfh (Carbon Dioxide) (MPN 0781-3642)
VICTOR
VICTOR Gas Regulator: CGA 320 Inlet, 5/8"-18 F RH Outlet, 80 scfh (Argon) /80 scfh (Carbon Dioxide) (MPN 0781-3642)
VICTOR Regulator: CGA 580 Inlet, 5/8"-18 F RH Outlet, 50 scfh (Argon) /50 scfh (Carbon Dioxide) (MPN 0781-4236)
VICTOR
VICTOR Regulator: CGA 580 Inlet, 5/8"-18 F RH Outlet, 50 scfh (Argon) /50 scfh (Carbon Dioxide) (MPN 0781-4236)