Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

3G Electric
WHITE-RODGERS 16A60 009S1 Freeze Protection Indoor Single-Stage Control - Freeze Protection Indoor Single-Stage Controls
WHITE-RODGERSFreeze Protection Indoor Single-Stage Controls

WHITE-RODGERS 16A60 009S1 Freeze Protection Indoor Single-Stage Control

The WHITE-RODGERS Freeze Protection Control (SKU 16A60 009S1, MPN 16A60 009S1) is a single-stage indoor freeze protection control with a steel enclosure and a 10 ft capillary with a 5-3/4 in x 3/8 in bulb. It…

SKU 3G-OTH-67833

Also listed as: 16A60009S1 · 16A60-009S1

Brand
WHITE-RODGERS
Item
16A60 009S1 Freeze Protection Indoor Single-Stage Control
Part Number
16A60 009S1
Category
Freeze Protection Indoor Single-Stage Controls
Available to Order
Also known as:16A60 009S1WHITE-RODGERS
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

WHITE-RODGERS
Manufacturer Part Number
16A60 009S1
Type
Steel, Manual Reset
Voltage
120/240V AC
w/Capillary
-30° to 50°F
Differential Type
Manual Reset
Enclosure Material
Steel
Switch Type/Action
SPST, Close on Rise
Temperature Differential
Manual Reset
Temperature Control Range
-30° to 50°F
Capillary Length/Bulb Diameter
10 ft Capillary, 5-3/4 in x 3/8 in Bulb

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

WHITE-RODGERS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The WHITE-RODGERS Freeze Protection Control (SKU 16A60 009S1, MPN 16A60 009S1) is a single-stage indoor freeze protection control with a steel enclosure and a 10 ft capillary with a 5-3/4 in x 3/8 in bulb. It features a manual reset temperature differential, an SPST switch action that closes on rise, and a temperature control range of -30° to 50°F. The control operates on 120/240V AC voltage.

Frequently Asked Questions

What is the WHITE-RODGERS 16A60 009S1 freeze protection control used for?

The WHITE-RODGERS 16A60 009S1 is a single-stage indoor freeze protection control that prevents pipes and equipment from freezing by closing a circuit on temperature rise. It is commonly used in HVAC systems, boiler rooms, and commercial buildings where maintaining minimum ambient temperature is critical.

What are the specifications of the WHITE-RODGERS 16A60 009S1?

The WHITE-RODGERS 16A60 009S1 has a temperature control range of -30° to 50°F, SPST switch action that closes on rise, manual reset differential, and operates on 120/240V AC. It includes a 10 ft capillary with a 5-3/4 in x 3/8 in bulb and a steel enclosure.

Where to buy WHITE-RODGERS 16A60 009S1 worldwide?

3G Electric supplies the WHITE-RODGERS 16A60 009S1 freeze protection control worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time.

How to install the WHITE-RODGERS 16A60 009S1 freeze protection control?

Mount the steel enclosure securely indoors, route the 10 ft capillary bulb to the protected area, and connect 120/240V AC power to the SPST contacts. The manual reset requires a physical button press after a freeze event. Always follow local electrical codes and the manufacturer's instructions.

Used in

Common applications for WHITE-RODGERS
Residential furnace replacement — White-Rodgers 767A-377 hot surface igniter for Trane gas furnaces
Commercial HVAC control retrofits — White-Rodgers 90-T60C3 Class 2 transformer for 24V control circuits
Hydronic zone heating systems — White-Rodgers 13 61 104S1 2-way zone valve for multi-zone temperature control
Plenum temperature regulation — White-Rodgers 05D51 035S1 fan and limit control for forced-air furnaces
OEM furnace control board replacement — White-Rodgers 50N02A-820 integrated ignition control for Trane systems
Fan relay and transformer integration — White-Rodgers 90 118ES1 for compact HVAC control panels
Not sure this is the right part? Photo-identify it

WHITE-RODGERS Products

3G Electric supplies WHITE-RODGERS freeze protection indoor single-stage controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
WHITE-RODGERS
WHITE-RODGERS
Surface mount limit control with SPST switch, auto reset, and 30°F differential. Opens on temperature rise at 60°F and closes at 40°F. Used in HVAC and industrial heating systems to prevent overheating in ducts, furnaces, or process equipment
WHITE-RODGERS
WHITE-RODGERS
Surface-mount limit control with SPST switch, auto reset, and 30°F differential. Opens on temperature rise at 180°F and closes at 150°F. Used in HVAC and industrial heating systems to prevent overheating in furnaces, boilers, and similar equipment
WHITE-RODGERS
WHITE-RODGERS
SPST automatic reset limit control with a 30°F differential. Opens on temperature rise at 160°F and closes at 130°F. Surface-mount design for use in HVAC and industrial heating systems to prevent overheating
WHITE-RODGERS
WHITE-RODGERS
SPST automatic reset limit control with 30°F differential, closes at 110°F and opens at 140°F. Surface mount design for over-temperature protection in HVAC and industrial heating systems
WHITE-RODGERS
WHITE-RODGERS
Surface mount limit control with SPST switch and automatic reset. Opens on temperature rise at 200°F and closes at 160°F. Rated for 120V AC. Used in HVAC and heating systems to interrupt power when temperature exceeds the set point
WHITE-RODGERS
WHITE-RODGERS
Surface mount limit control with SPST switch, auto reset operation. Opens on temperature rise at 175°F and closes at 135°F. Used for over-temperature protection in HVAC systems, furnaces, boilers, and similar heating equipment

More from WHITE-RODGERS

View all WHITE-RODGERS parts

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first