Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

WILKINS 34-375XLB Reduced Pressure Zone Backflow Preventer - Zurn RPZ Backflow Preventers
WILKINSZurn RPZ Backflow Preventers

WILKINS 34-375XLB Reduced Pressure Zone Backflow Preventer

The WILKINS Reduced Pressure Zone Backflow Preventer: 375XLB is a Zurn RPZ Backflow Preventer designed for industrial applications. This bronze unit features FNPT connections and a ball valve shut-off type, with…

SKU 3G-OTH-440407

Also listed as: 34375XLB · 34 375XLB

Brand
WILKINS
Item
34-375XLB Reduced Pressure Zone Backflow Preventer
Category
Zurn RPZ Backflow Preventers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

WILKINS
Manufacturer Part Number
34-375XLB
Type
Std Configuration, Bronze, FNPT
Connection Type
FNPT
Shut-Off Valve Type
Ball Valve

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

WILKINS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The WILKINS Reduced Pressure Zone Backflow Preventer: 375XLB is a Zurn RPZ Backflow Preventer designed for industrial applications. This bronze unit features FNPT connections and a ball valve shut-off type, with manufacturer part number 34-375XLB. It is configured as a standard assembly for backflow prevention.

Frequently Asked Questions

What is the WILKINS 375XLB Reduced Pressure Zone Backflow Preventer used for?

The WILKINS 375XLB is a Zurn RPZ backflow preventer used in industrial water systems to stop contaminated water from flowing backward into the potable supply. It is commonly installed on fire sprinkler lines, irrigation systems, and boiler feed lines where cross-connection hazards exist.

What are the specifications of the WILKINS 375XLB backflow preventer?

The WILKINS 375XLB is a bronze reduced pressure zone assembly with FNPT connections and a ball valve shut-off type. It is a standard configuration unit with manufacturer part number 34-375XLB. This Zurn product is designed for backflow prevention in industrial piping systems.

Where to buy the WILKINS 375XLB backflow preventer worldwide?

3G Electric supplies the WILKINS 375XLB backflow preventer worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time on this Zurn RPZ assembly.

How to install a WILKINS 375XLB reduced pressure zone backflow preventer?

Install the WILKINS 375XLB in a horizontal position with adequate clearance for testing and maintenance. Ensure flow direction matches the arrow on the body. Use pipe dope on FNPT threads and support the valve to avoid stress. Always follow local plumbing codes and manufacturer guidelines.

Used in

Common applications for WILKINS
Commercial water distribution — WILKINS 600XL series pressure reducing valves for regulating supply pressure in multi-story buildings.
Irrigation systems — WILKINS 975XL2 backflow preventers to protect potable water from contamination in agricultural setups.
Industrial process control — WILKINS 375ST reduced pressure principle backflow preventers for cross-connection control in manufacturing plants.
Municipal water treatment — WILKINS low-lead pressure regulators like the 1-600XL3DU for compliance with potable water standards.
HVAC systems — WILKINS 112-NR3XLDULU regulators for maintaining consistent water pressure in heating and cooling loops.
Fire protection systems — WILKINS backflow preventers for backflow prevention in sprinkler and standpipe systems.

WILKINS Products

3G Electric supplies WILKINS zurn rpz backflow preventers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Reduced pressure zone backflow preventer in standard configuration. Constructed of bronze with female NPT connections and ball valve shut-off. Used in commercial and industrial plumbing systems to prevent backflow of contaminated water into potable water supplies
WILKINS
Reduced pressure zone backflow preventer in standard configuration. Constructed of bronze with female NPT connections and ball valve shut-off. Used in commercial and industrial plumbing systems to prevent backflow of contaminated water into potable water supplies
Reduced pressure zone backflow preventer in standard configuration. Bronze body with female NPT connections and ball valve shut-off. Used in water supply systems to prevent backflow contamination
WILKINS
Reduced pressure zone backflow preventer in standard configuration. Bronze body with female NPT connections and ball valve shut-off. Used in water supply systems to prevent backflow contamination
Reduced pressure zone backflow preventer in standard configuration. Constructed of bronze with female NPT connections and ball valve shut-off. Used in commercial and industrial plumbing systems to prevent backflow contamination in potable water lines, irrigation, and fire protection
WILKINS
Reduced pressure zone backflow preventer in standard configuration. Constructed of bronze with female NPT connections and ball valve shut-off. Used in commercial and industrial plumbing systems to prevent backflow contamination in potable water lines, irrigation, and fire protection
Reduced pressure zone backflow preventer in standard configuration. Bronze body with 1-inch female NPT connections and ball valve shut-off. Used to protect potable water supplies from contamination due to backflow or backsiphonage in commercial, industrial, and municipal water systems
WILKINS
Reduced pressure zone backflow preventer in standard configuration. Bronze body with 1-inch female NPT connections and ball valve shut-off. Used to protect potable water supplies from contamination due to backflow or backsiphonage in commercial, industrial, and municipal water systems
Reduced pressure zone backflow preventer in standard configuration. Bronze body with 2-inch FNPT connections and ball valve shut-off. Used to prevent reverse flow in potable water systems
WILKINS
Reduced pressure zone backflow preventer in standard configuration. Bronze body with 2-inch FNPT connections and ball valve shut-off. Used to prevent reverse flow in potable water systems
Reduced pressure zone backflow preventer in standard configuration. Bronze body with female NPT connections and ball valve shut-offs. Used in water supply systems to prevent backflow from high-hazard cross-connections
WILKINS
Reduced pressure zone backflow preventer in standard configuration. Bronze body with female NPT connections and ball valve shut-offs. Used in water supply systems to prevent backflow from high-hazard cross-connections

More from WILKINS

View all WILKINS parts
WILKINS
WILKINS
Reduced pressure principle backflow preventer with 304L stainless steel body and flanged connections. Standard configuration includes NRS gate valve shut-off. Used to protect potable water supplies from cross-connection contamination in commercial, industrial, and municipal applications
Bronze RPZ backflow preventer with standard configuration, 2 in FNPT connections, and ball valve shut-offs. Used in commercial and municipal water systems to prevent backflow contamination under high-hazard conditions
WILKINS
Bronze RPZ backflow preventer with standard configuration, 2 in FNPT connections, and ball valve shut-offs. Used in commercial and municipal water systems to prevent backflow contamination under high-hazard conditions
This WILKINS 975XL2 reduced pressure zone (RPZ) backflow preventer is designed to protect potable water supplies from contamination due to back-siphonage or back-pressure. The bronze body unit features a built-in strainer and ball valve shut-off valves, with 3/4 inch female NPT connections. It operates within a temperature range of 33°F to 180°F and is suitable for commercial and industrial plumbing applications requiring a reduced pressure zone assembly
WILKINS
This WILKINS 975XL2 reduced pressure zone (RPZ) backflow preventer is designed to protect potable water supplies from contamination due to back-siphonage or back-pressure. The bronze body unit features a built-in strainer and ball valve shut-off valves, with 3/4 inch female NPT connections. It operates within a temperature range of 33°F to 180°F and is suitable for commercial and industrial plumbing applications requiring a reduced pressure zone assembly
WILKINS Zurn RPZ backflow preventer with 304L stainless steel body and flange connections. Standard configuration with NRS gate valve shut-off. Used in industrial fluid systems to prevent backflow in high-pressure or corrosive environments
WILKINS
WILKINS Zurn RPZ backflow preventer with 304L stainless steel body and flange connections. Standard configuration with NRS gate valve shut-off. Used in industrial fluid systems to prevent backflow in high-pressure or corrosive environments
Reduced pressure zone backflow preventer in standard configuration. Constructed of bronze with 1 in pipe size and ball valve shut-off. Temperature range 33°F to 180°F. Used in commercial and industrial plumbing systems to protect potable water from cross-connections
WILKINS
Reduced pressure zone backflow preventer in standard configuration. Constructed of bronze with 1 in pipe size and ball valve shut-off. Temperature range 33°F to 180°F. Used in commercial and industrial plumbing systems to protect potable water from cross-connections
Reduced pressure zone backflow preventer with bronze body, 2-inch FNPT connections, and integral strainer. Includes ball valve shut-offs on inlet and outlet. Rated for operating temperatures from 33°F to 180°F. Used in commercial and industrial water systems to prevent backflow contamination
WILKINS
Reduced pressure zone backflow preventer with bronze body, 2-inch FNPT connections, and integral strainer. Includes ball valve shut-offs on inlet and outlet. Rated for operating temperatures from 33°F to 180°F. Used in commercial and industrial water systems to prevent backflow contamination
Standard-configuration reduced-pressure zone backflow preventer with bronze body, 1-1/2 in pipe size, male NPT connections, and ball valve shut-off. Used in water supply systems to prevent backflow contamination
WILKINS
Standard-configuration reduced-pressure zone backflow preventer with bronze body, 1-1/2 in pipe size, male NPT connections, and ball valve shut-off. Used in water supply systems to prevent backflow contamination
Reduced pressure zone backflow preventer with ductile iron body and standard configuration. Designed for 6-inch pipe size, featuring NRS gate valve shut-off. Used in commercial and municipal water systems to prevent backflow contamination
WILKINS
Reduced pressure zone backflow preventer with ductile iron body and standard configuration. Designed for 6-inch pipe size, featuring NRS gate valve shut-off. Used in commercial and municipal water systems to prevent backflow contamination