Send a part number, a photo, or a whole BOM — we supply it and stand behind it. EXW Singapore — collect from our office.

3G Electric
YELLOW JACKET 49124 Analog Low Side Compound Pressure Gauge, 0-800 psi, R-454B - Analog Low Side Compound Pressure Gauges
YELLOW JACKETAnalog Low Side Compound Pressure Gauges

YELLOW JACKET 49124 Analog Low Side Compound Pressure Gauge, 0-800 psi, R-454B

The YELLOW JACKET Low Side Gauge (MPN 49124) is an analog low side compound pressure gauge designed for use with R-454B refrigerant. It features a 3 1/8-inch diameter, non-liquid filled dial with a pressure range of…

SKU 3G-OTH-72652

Brand
YELLOW JACKET
Item
49124 Analog Low Side Compound Pressure Gauge, 0-800 psi, R-454B
Part Number
49124
Category
Analog Low Side Compound Pressure Gauges
Available to Order
Also known as:49124YELLOW JACKET
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.

Technical Specifications

YELLOW JACKET
Manufacturer Part Number
49124
Type
0 psi to 800 psi, Non-Liquid Filled
Dia
3 1/8 in
Color
Blue
Accuracy
± 1%
For Refrigerant Type
R-454B
Calibration Certificate Type
Not Certified

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

YELLOW JACKET Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The YELLOW JACKET Low Side Gauge (MPN 49124) is an analog low side compound pressure gauge designed for use with R-454B refrigerant. It features a 3 1/8-inch diameter, non-liquid filled dial with a pressure range of 0 psi to 800 psi and an accuracy of ± 1%. This blue gauge is not certified with a calibration certificate.

Frequently Asked Questions

What is the YELLOW JACKET Low Side Gauge 49124 used for?

The YELLOW JACKET Low Side Gauge 49124 is an analog low side compound pressure gauge used for measuring pressure in HVACR systems that use R-454B refrigerant. It is commonly employed by technicians during installation, maintenance, and troubleshooting of commercial and industrial refrigeration and air conditioning equipment.

What are the specifications of the YELLOW JACKET Low Side Gauge 49124?

The YELLOW JACKET Low Side Gauge 49124 has a pressure range of 0 psi to 800 psi, an accuracy of ± 1%, and a 3 1/8-inch diameter non-liquid filled dial. It is blue, designed for R-454B refrigerant, and is not supplied with a calibration certificate.

Where to buy the YELLOW JACKET Low Side Gauge 49124 worldwide?

You can source the YELLOW JACKET Low Side Gauge 49124 through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations, ensuring the gauge reaches your facility reliably.

How to select the correct YELLOW JACKET low side gauge for R-454B?

To select the correct YELLOW JACKET low side gauge for R-454B, verify the gauge is rated for that refrigerant type, as the 49124 model is. Ensure the pressure range covers your system's operating pressures (0 psi to 800 psi) and that the accuracy (± 1%) meets your application requirements.

Used in

Common applications for YELLOW JACKET
HVAC service — Yellow Jacket Series 41 analog manifold gauge set (MPN 42035) for measuring and controlling refrigerant pressure in R-32, R-410A, and R-454B systems.
Refrigerant charging — Yellow Jacket wireless electronic refrigerant scale (MPN 68864) for precise weighing of refrigerant during charging, recovery, or evacuation.
Evacuation pump maintenance — Yellow Jacket ISO-46 evacuation pump oil (MPN 93092) for lubricating and maintaining vacuum pumps in refrigeration service.
Plumbing maintenance — Yellow Jacket 12-piece ratchet hand bender set (MPN 63325) for bending, cutting, and reaming pipe in HVAC and plumbing tasks.
Low-pressure measurement — Yellow Jacket portable analog manometer (Series 78075) for measuring gas pressure from 0 to 2 inches water column in HVAC systems.
Tube sizing — Yellow Jacket sizing gauge (MPN 60297) for identifying tube dimensions when selecting fittings and making connections with manifolds and hoses.
Not sure this is the right part? Photo-identify it→

YELLOW JACKET Products

3G Electric supplies YELLOW JACKET analog low side compound pressure gauges. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

More from YELLOW JACKET

View all YELLOW JACKET parts →
Analog low side compound pressure gauge with a 3 1/8 in diameter non-liquid filled dial. Measures 0 psi to 120 psi with ±1% accuracy. Blue color. Designed for use with R-404A refrigerant in HVACR systems for low-side pressure measurement during service and troubleshooting
YELLOW JACKET
Analog low side compound pressure gauge with a 3 1/8 in diameter non-liquid filled dial. Measures 0 psi to 120 psi with ±1% accuracy. Blue color. Designed for use with R-404A refrigerant in HVACR systems for low-side pressure measurement during service and troubleshooting
YELLOW JACKET
YELLOW JACKET
Analog low side compound pressure gauge for R-502 refrigerant systems. Features a 2 1/2 in blue dial, 1/8 in male NPT connection, and ± 3-2-3% accuracy. Non-liquid filled with NIST calibration certification. Suitable for measuring vacuum and positive pressure in HVAC-R low side applications

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first