Send a part number, a photo, or a whole BOM — we supply it and stand behind it. EXW Singapore — collect from our office.

3G Electric
YELLOW JACKET Two-Stage Vacuum Pump - Ammonia Refrigeration Evacuation Pumps
YELLOW JACKETAmmonia Refrigeration Evacuation Pumps

YELLOW JACKET Two-Stage Vacuum Pump

The YELLOW JACKET Vacuum Pump (MPN 93530) is a two-stage ammonia refrigeration evacuation pump with an 8 cfm displacement and a 15 micron ultimate vacuum rating. It operates on 120V AC with a 5-15P plug configuration…

SKU 3G-OTH-71718

Brand
YELLOW JACKET
Item
Two-Stage Vacuum Pump
Part Number
93530
Category
Ammonia Refrigeration Evacuation Pumps
Available to Order
Also known as:93530YELLOW JACKET
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.

Technical Specifications

YELLOW JACKET
Manufacturer Part Number
93530
Type
Not A2L Compatible, Male, NPT
AC
120V
Product Type
Vacuum Pump
Ultimate Vacuum
15 micron
Number of Stages
Two-Stage
Plug Configuration
5-15P

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

YELLOW JACKET Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The YELLOW JACKET Vacuum Pump (MPN 93530) is a two-stage ammonia refrigeration evacuation pump with an 8 cfm displacement and a 15 micron ultimate vacuum rating. It operates on 120V AC with a 5-15P plug configuration and features a male NPT connection. This pump is not A2L compatible.

Frequently Asked Questions

What is the YELLOW JACKET Vacuum Pump 93530 used for?

The YELLOW JACKET Vacuum Pump 93530 is used for evacuating ammonia refrigeration systems. Its two-stage design and 15 micron ultimate vacuum rating make it suitable for deep evacuation of industrial refrigeration circuits to remove moisture and non-condensables before charging.

What are the specifications of the YELLOW JACKET Vacuum Pump 93530?

The YELLOW JACKET Vacuum Pump 93530 is a two-stage pump with 8 cfm displacement and 15 micron ultimate vacuum. It operates on 120V AC with a 5-15P plug, has a male NPT connection, and is not A2L compatible. The manufacturer part number is 93530.

Where to buy the YELLOW JACKET Vacuum Pump 93530 worldwide?

You can source the YELLOW JACKET Vacuum Pump 93530 through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations. Contact us for availability and lead time.

How to select a YELLOW JACKET Vacuum Pump for ammonia refrigeration?

Select a YELLOW JACKET Vacuum Pump like the 93530 based on system size: 8 cfm displacement suits medium ammonia circuits. Ensure the ultimate vacuum rating (15 micron) meets your evacuation depth requirement. Verify voltage (120V AC) and connection type (male NPT) match your setup.

Used in

Common applications for YELLOW JACKET
HVAC service — Yellow Jacket Series 41 analog manifold gauge set (MPN 42035) for measuring and controlling refrigerant pressure in R-32, R-410A, and R-454B systems.
Refrigerant charging — Yellow Jacket wireless electronic refrigerant scale (MPN 68864) for precise weighing of refrigerant during charging, recovery, or evacuation.
Evacuation pump maintenance — Yellow Jacket ISO-46 evacuation pump oil (MPN 93092) for lubricating and maintaining vacuum pumps in refrigeration service.
Plumbing maintenance — Yellow Jacket 12-piece ratchet hand bender set (MPN 63325) for bending, cutting, and reaming pipe in HVAC and plumbing tasks.
Low-pressure measurement — Yellow Jacket portable analog manometer (Series 78075) for measuring gas pressure from 0 to 2 inches water column in HVAC systems.
Tube sizing — Yellow Jacket sizing gauge (MPN 60297) for identifying tube dimensions when selecting fittings and making connections with manifolds and hoses.
Not sure this is the right part? Photo-identify it→

YELLOW JACKET Products

3G Electric supplies YELLOW JACKET ammonia refrigeration evacuation pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories →Valves & Regulation →Motors & Drives →All Products →

Compatible alternatives & equivalents

More from YELLOW JACKET

View all YELLOW JACKET parts →

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first