Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

YORK High Altitude Conversion Kit: Mfr Part # S1-1PS0309 - Replacement HVACR Controls, Switches & Thermostats
YORKReplacement HVACR Controls, Switches & Thermostats

YORK High Altitude Conversion Kit: Mfr Part # S1-1PS0309

YORK Replacement HVACR Controls, Switches & Thermostats. Specifications: Product Type: High Altitude Conversion Kit.

SKU 3G-OTH-106151

Also listed as: S11PS0309 · S1 1PS0309

Brand
YORK
Item
High Altitude Conversion Kit: Mfr Part # S1-1PS0309
Category
Replacement HVACR Controls, Switches & Thermostats
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

YORK
Manufacturer Part Number
S1-1PS0309
Product Type
High Altitude Conversion Kit

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

YORK Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

YORK Replacement HVACR Controls, Switches & Thermostats. Specifications: Product Type: High Altitude Conversion Kit.

Frequently Asked Questions

What is a YORK High Altitude Conversion Kit used for?

A YORK High Altitude Conversion Kit adjusts HVAC burner and control settings for safe, efficient operation at elevations above 2000 feet. It prevents incomplete combustion and nuisance shutdowns in furnaces and rooftop units, ensuring reliable performance in mountainous regions.

What are the specifications of the YORK S1-1PS0309 High Altitude Conversion Kit?

The YORK S1-1PS0309 is a High Altitude Conversion Kit with manufacturer part number S1-1PS0309. It is designed for YORK HVAC equipment to modify gas pressure and airflow for altitudes above 2000 feet. 3G Electric supplies this genuine YORK kit for worldwide delivery.

Where to buy a YORK High Altitude Conversion Kit worldwide?

3G Electric supplies the YORK S1-1PS0309 High Altitude Conversion Kit to customers worldwide. We handle full logistics, customs clearance, and delivery to your site. Contact us for a quote and lead time on this genuine YORK part.

How to install a YORK High Altitude Conversion Kit?

Installation of a YORK High Altitude Conversion Kit requires shutting off gas and power, then replacing the existing orifice and adjusting the gas valve regulator per the kit’s instructions. Always verify manifold pressure with a manometer and check for proper combustion. Consult a licensed HVAC technician.

Used in

Common applications for YORK
Commercial HVAC maintenance — YORK blower wheels (SKU 208P91) for replacing worn fans in rooftop units
Residential heating repair — YORK heater elements (SKU 208V68) for electric furnace restoration
Condensate management — YORK condensate pan kits (SKU 208R56) for preventing water damage in air handlers
Airflow system repair — YORK blower scroll vents (SKU 208P50) for correcting venturi performance in gas furnaces
Temperature monitoring — YORK immersion sensors (SKU 817W33) for chiller or boiler control loops
Heat exchanger servicing — YORK heater elements (SKU 208V63) for replacing failed components in packaged units

YORK Products

3G Electric supplies YORK replacement hvacr controls, switches & thermostats. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
YORK Low Ambient Kit: Mfr Part # S1-2LA06700424
YORK
YORK Low Ambient Kit: Mfr Part # S1-2LA06700424
YORK Switching Relay: Mfr Part # S1-024-36082-000
YORK
YORK Switching Relay: Mfr Part # S1-024-36082-000
YORK Transformer: Mfr Part # S1-7945-3551
YORK
YORK Transformer: Mfr Part # S1-7945-3551
YORK Switching Relay: Mfr Part # S1-024-21678-700
YORK
YORK Switching Relay: Mfr Part # S1-024-21678-700
YORK Transformer: Mfr Part # S1-025-18452-700
YORK
YORK Transformer: Mfr Part # S1-025-18452-700
YORK Switching Relay: Mfr Part # S1-024-36022-000
YORK
YORK Switching Relay: Mfr Part # S1-024-36022-000

More from YORK

View all YORK parts
Gas pilot tube for HVAC systems, delivering gas to the pilot burner for ignition in furnaces, boilers, and other gas-fired heating equipment. Suitable for residential and commercial applications
YORK
Gas pilot tube for HVAC systems, delivering gas to the pilot burner for ignition in furnaces, boilers, and other gas-fired heating equipment. Suitable for residential and commercial applications
Replacement temperature control for HVACR systems, used to regulate temperature in commercial heating, ventilation, air conditioning, and refrigeration equipment. Designed as a direct replacement component for YORK systems
YORK
Replacement temperature control for HVACR systems, used to regulate temperature in commercial heating, ventilation, air conditioning, and refrigeration equipment. Designed as a direct replacement component for YORK systems
Replacement transformer for HVACR systems, stepping down voltage to power low-voltage control circuits in heating, ventilation, air conditioning, and refrigeration equipment
YORK
Replacement transformer for HVACR systems, stepping down voltage to power low-voltage control circuits in heating, ventilation, air conditioning, and refrigeration equipment
Temperature sensor for HVACR systems, used to monitor leaving air or fluid temperature from a coil or duct. Supports system performance optimization in commercial and industrial heating, cooling, and refrigeration applications
YORK
Temperature sensor for HVACR systems, used to monitor leaving air or fluid temperature from a coil or duct. Supports system performance optimization in commercial and industrial heating, cooling, and refrigeration applications
Replacement pressure switch for HVACR systems. Monitors and controls refrigerant or air pressure to protect compressors and other components. Opens or closes electrical contacts at preset pressure thresholds for safe operation
YORK
Replacement pressure switch for HVACR systems. Monitors and controls refrigerant or air pressure to protect compressors and other components. Opens or closes electrical contacts at preset pressure thresholds for safe operation
Electric sequencer for staging heating elements in HVAC systems. Controls the order and timing of electric heat stages to prevent electrical overload. Used as a replacement part in compatible heating and cooling equipment
YORK
Electric sequencer for staging heating elements in HVAC systems. Controls the order and timing of electric heat stages to prevent electrical overload. Used as a replacement part in compatible heating and cooling equipment
This pressure switch is a replacement HVACR control used in commercial and industrial heating, ventilation, air conditioning, and refrigeration systems. It monitors refrigerant or air pressure to protect compressors and ensure safe system operation
YORK
This pressure switch is a replacement HVACR control used in commercial and industrial heating, ventilation, air conditioning, and refrigeration systems. It monitors refrigerant or air pressure to protect compressors and ensure safe system operation
Replacement limit control for HVACR systems, used to monitor temperature or pressure and shut down the unit if unsafe conditions occur. Commonly applied in commercial and industrial heating and cooling equipment
YORK
Replacement limit control for HVACR systems, used to monitor temperature or pressure and shut down the unit if unsafe conditions occur. Commonly applied in commercial and industrial heating and cooling equipment