ZURN WILKINS BFP-8F Lead-Free Hose Bibb Vacuum Breaker - Lead-Free Hose Bibb Vacuum Breakers
ZURN WILKINSLead-Free Hose Bibb Vacuum Breakers

ZURN WILKINS BFP-8F Lead-Free Hose Bibb Vacuum Breaker

The ZURN WILKINS BFP-8F is a lead-free hose bibb vacuum breaker designed for back-siphonage protection in water media applications. This rough brass, brass-bodied unit features male GHT and female GHT connections, a…

SKU 3G-OTH-439336

Also listed as: BFP8F · BFP 8F

Brand
ZURN WILKINS
Item
BFP-8F Lead-Free Hose Bibb Vacuum Breaker
Category
Lead-Free Hose Bibb Vacuum Breakers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

ZURN WILKINS
Manufacturer Part Number
BFP-8F
Type
180°F, Brass, Back-Siphonage, Rough Brass, Male, GHT
Includes
Set Screw
For Media
Water
Standards
ASSE Listed 1011
Drain Type
No Drain
Body Finish
Rough Brass
Body Material
Brass
Seal Material
Buna-N
Protection Type
Back-Siphonage
Spring Material
Stainless Steel
Freeze Protection
No
Security Mechanism
Break-Away Set Screw
Vacuum Breaker Style
Hose Bib Vacuum Breaker
Hazard Protection Level
Low Health Hazard
Connection Type - Side 1
GHT
Connection Type - Side 2
GHT
Connection Gender - Side 1
Male
Connection Gender - Side 2
Female

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

ZURN WILKINS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The ZURN WILKINS BFP-8F is a lead-free hose bibb vacuum breaker designed for back-siphonage protection in water media applications. This rough brass, brass-bodied unit features male GHT and female GHT connections, a Buna-N seal, and a stainless steel spring. It is ASSE Listed 1011 for low health hazard protection and includes a break-away set screw security mechanism.

Frequently Asked Questions

What is the ZURN WILKINS BFP-8F vacuum breaker used for?

The ZURN WILKINS BFP-8F is a lead-free hose bibb vacuum breaker that prevents back-siphonage of contaminated water into potable water lines. It is used in outdoor hose connections, irrigation systems, and commercial water applications where low health hazard protection is required.

What are the specifications of the ZURN WILKINS BFP-8F?

The BFP-8F has a brass body with rough brass finish, male and female GHT connections, a Buna-N seal, and a stainless steel spring. It is rated for water media up to 180°F, ASSE Listed 1011 for low health hazard back-siphonage protection, and includes a break-away set screw security mechanism.

Where to buy the ZURN WILKINS BFP-8F worldwide?

3G Electric supplies the ZURN WILKINS BFP-8F vacuum breaker worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time on this lead-free hose bibb vacuum breaker.

How to install the ZURN WILKINS BFP-8F vacuum breaker?

Install the BFP-8F by threading the male GHT connection onto a compatible female hose bibb. Tighten by hand, then use the break-away set screw to secure the unit against tampering. Ensure the vacuum breaker is installed vertically and above any downstream valves for proper back-siphonage protection.

Used in

Common applications for ZURN WILKINS
Commercial building water supply — ZURN WILKINS 350XL double check backflow preventer for cross-connection control
Industrial process lines — ZURN WILKINS 3-ZW209 automatic control valve for pressure regulation
Municipal irrigation systems — ZURN WILKINS 1-710 pressure vacuum breaker for backflow prevention
Potable water distribution — ZURN WILKINS 34-20XLDULU water pressure regulator for reducing inlet pressure
Fire protection systems — ZURN WILKINS 950XLTDA reduced-pressure zone backflow detector for high-hazard applications
HVAC makeup water — ZURN WILKINS 212-500XLFC flanged pressure reducing valve for boiler feed control

ZURN WILKINS Products

3G Electric supplies ZURN WILKINS lead-free hose bibb vacuum breakers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Lead-free pressure vacuum breaker with FNPT x FNPT connections for water media. Rated for back-siphonage applications within a temperature range of 33°F to 110°F. Used in plumbing systems to prevent reverse flow of contaminated water into potable water supplies
ZURN WILKINS
Lead-free pressure vacuum breaker with FNPT x FNPT connections for water media. Rated for back-siphonage applications within a temperature range of 33°F to 110°F. Used in plumbing systems to prevent reverse flow of contaminated water into potable water supplies
Lead-free pressure vacuum breaker with FNPT x FNPT connections for water media. Rated for 180°F and high health hazard applications. Provides backflow prevention in piping systems to protect potable water supplies from cross-connections
ZURN WILKINS
Lead-free pressure vacuum breaker with FNPT x FNPT connections for water media. Rated for 180°F and high health hazard applications. Provides backflow prevention in piping systems to protect potable water supplies from cross-connections
Lead-free pressure vacuum breaker with FNPT x FNPT connections for water media up to 180°F. Rated for high health hazard backflow prevention. NPT threaded assembly suitable for industrial water systems
ZURN WILKINS
Lead-free pressure vacuum breaker with FNPT x FNPT connections for water media up to 180°F. Rated for high health hazard backflow prevention. NPT threaded assembly suitable for industrial water systems
Lead-free pressure vacuum breaker for back-siphonage prevention in water systems. Features FNPT x FNPT connections and operates in temperatures from 33°F to 110°F. Suitable for commercial or industrial water lines to protect potable water supplies
ZURN WILKINS
Lead-free pressure vacuum breaker for back-siphonage prevention in water systems. Features FNPT x FNPT connections and operates in temperatures from 33°F to 110°F. Suitable for commercial or industrial water lines to protect potable water supplies
Lead-free pressure vacuum breaker for water media. Rated for 140°F and designed for high health hazard back-siphonage protection. Suitable for commercial and industrial plumbing systems requiring backflow prevention
ZURN WILKINS
Lead-free pressure vacuum breaker for water media. Rated for 140°F and designed for high health hazard back-siphonage protection. Suitable for commercial and industrial plumbing systems requiring backflow prevention
The ZURN WILKINS 34-710 is a pressure vacuum breaker with FNPT x FNPT connections, designed for water media. It operates within a temperature range of 33°F to 140°F and is intended for high health hazard applications. This device is used to prevent backflow of contaminated water into potable water systems in commercial or industrial plumbing installations
ZURN WILKINS
The ZURN WILKINS 34-710 is a pressure vacuum breaker with FNPT x FNPT connections, designed for water media. It operates within a temperature range of 33°F to 140°F and is intended for high health hazard applications. This device is used to prevent backflow of contaminated water into potable water systems in commercial or industrial plumbing installations

More from ZURN WILKINS

View all ZURN WILKINS parts
The ZURN WILKINS BFP-9 is a lead-free hose bibb vacuum breaker with Female GHT x Male GHT connections, designed for back-siphonage protection against low health hazards in water systems. It features a rough brass body, Buna-N seals, stainless steel spring, and a break-away set screw for security. Rated for water media up to 180°F, it is ASSE Listed 1011 and includes a set screw. Commonly installed on outdoor faucets or industrial hose connections
ZURN WILKINS
The ZURN WILKINS BFP-9 is a lead-free hose bibb vacuum breaker with Female GHT x Male GHT connections, designed for back-siphonage protection against low health hazards in water systems. It features a rough brass body, Buna-N seals, stainless steel spring, and a break-away set screw for security. Rated for water media up to 180°F, it is ASSE Listed 1011 and includes a set screw. Commonly installed on outdoor faucets or industrial hose connections