We supply parts. EXW Singapore: collect from our office.

Home›Resources›3G-OTH-42386 Relay, 4 P 220 V: The Complete Buyer's Guide for International Sourcing

3G-OTH-42386 Relay, 4 P 220 V: The Complete Buyer's Guide for International Sourcing

A 3G-OTH-42386 Relay, 4 P 220 V is a four-pole industrial control relay with a 220 V coil, used for switching multiple circuits in panels and machinery. This guide explains specs, selection, and sourcing for international buyers, including 50/60 Hz considerations and lockout/tagout accessories.
Publication Date24 November 2026 · 02:11 am
Technical Reviewer3G Electric Technical Team
3G-OTH-42386 Relay, 4 P 220 V: The Complete Buyer's Guide for International Sourcing
Controls
Table of Contentsexpand_more

The 3G-OTH-42386 Relay, 4 P 220 V is a four-pole industrial relay with a 220 V AC coil, designed to switch up to four separate circuits from a single control signal. It is commonly used in control panels, HVAC equipment, and industrial machinery where multiple loads must be controlled simultaneously. Buyers should verify coil voltage tolerance, contact current rating, and mounting style before ordering.

What is a 3G-OTH-42386 Relay, 4 P 220 V?

A 3G-OTH-42386 Relay, 4 P 220 V is a plug-in or panel-mount electromechanical relay featuring four poles (4P) and a 220 V AC coil. The “3G-OTH-42386” designation typically refers to a specific series or form factor, often associated with square-base relays with blade terminals. The 4P configuration allows simultaneous switching of four independent circuits, making it suitable for complex control logic.

Brands such as Schneider Electric, ABB, and Siemens offer comparable 4-pole relays in their industrial control ranges. For safety and identification, BRADY provides a range of 220 V hazard labels and lockout tags that are often used alongside such relays in panel environments.

Quotable definition

A 3G-OTH-42386 Relay, 4 P 220 V is a four-pole electromechanical control relay with a 220 V AC coil, used to switch multiple electrical circuits in industrial control panels, HVAC systems, and machinery. It typically features blade terminals for plug-in mounting and is rated for currents up to 10 A per pole.

How does a 3G-OTH-42386 Relay, 4 P 220 V work?

When a 220 V AC control voltage is applied to the coil, an electromagnetic field pulls the armature, closing (or opening) the four sets of contacts. This allows a low-power control signal to switch higher-power loads across multiple circuits. The relay is often used to interface between control systems (e.g., PLCs) and field devices such as motors, valves, or heaters.

The 220 V coil is common in industrial environments where 220–240 V AC control power is available. In 50 Hz systems (common in Europe, Asia, and Africa), the coil impedance is optimized for 50 Hz; in 60 Hz systems (North America, parts of Asia), the same relay may have a slightly different pull-in current. Always check the coil frequency rating.

Spec table (typical values for 3G-OTH-42386 series)

ParameterValueNotes
Contact configuration4-pole (4P)Typically 4PDT or 4PST
Coil voltage220 V AC50/60 Hz rated
Contact current rating5 A to 10 APer pole, resistive load
MountingPlug-in (blade terminals) or panel mountRequires socket for plug-in
Terminal typeBlade (0.187 in or 0.250 in)Check socket compatibility
Operating temperature-40 °C to +70 °CTypical industrial range
Mechanical life10 million operationsTypical
Electrical life100,000 operationsAt rated load

Note: Values are typical for the 3G-OTH-42386 series; always confirm with the specific manufacturer’s datasheet.

Types and applications

The 3G-OTH-42386 series may include variants with different contact materials (e.g., silver alloy for low-level signals), coil voltages (e.g., 24 V DC, 110 V AC), and mounting options. In International markets, the 220 V AC coil is prevalent in regions with 220–240 V supply, such as Europe, Asia, and Africa. Applications include:

  • Industrial control panels for motor starters and contactors
  • HVAC equipment: fan control, compressor staging
  • Packaging machinery: solenoid valve actuation
  • Lighting control in commercial buildings
  • Pump control panels (often paired with level sensors)

For safety, 220 V hazard labels and lockout tags are recommended. BRADY offers a range of adhesive labels and tags, such as the BRADY Polyester Danger: 220 Volts Labels and BRADY Danger Tags with Signature/Date Fields.

Selection criteria

  1. Coil voltage and frequency: Confirm 220 V AC and 50/60 Hz compatibility. In 60 Hz systems, the coil may draw slightly less current; ensure the relay is rated for both.
  2. Contact configuration: 4P is standard, but decide between 4PDT (double-throw) and 4PST (single-throw) based on whether you need normally open/closed contacts.
  3. Contact rating: Match the relay’s current rating (e.g., 5 A, 10 A) to your load. For inductive loads (motors, solenoids), derate by 50% or use a contactor.
  4. Mounting and termination: Choose plug-in with socket for easy replacement, or panel mount with screw terminals for permanent installations. Ensure socket compatibility.
  5. Environmental conditions: Consider ambient temperature, humidity, and vibration. Sealed relays are available for harsh environments.
  6. Safety and compliance: Use appropriate hazard labels (e.g., 220 V) and lockout/tagout tags during maintenance. BRADY’s 8-Pack of 220 V Danger Signs and Danger Tags with Remarks Field are suitable.

Product selection ladder: safety and identification accessories

While the 3G-OTH-42386 relay itself is the core component, proper safety marking is essential. The table below compares BRADY safety products from 3G Electric’s catalogue, arranged from light-duty labeling to heavy-duty lockout/tagout.

ProductTypeSize/PackApplication
BRADY Polyester Danger: 220 Volts LabelsAdhesive label3.5 in x 5 in, 0.01 in thickIndoor equipment marking
BRADY Polyester Danger: 220 Volts Signs (5-Pack)Adhesive sign3.5 in x 5 in, pack of 5Indoor panels and walls
BRADY Reflective Danger: 220 Volts Signs (8-Pack)Adhesive sign8-pack, reflective sheetingLow-light or outdoor
BRADY Danger Tags with Signature/Date (100-Pack)Cardstock tag100 tags, cotton stringLockout/tagout procedures
BRADY Danger Tags with Remarks Field (100-Pack)Paper tag100 tags, cotton stringDetailed lockout/tagout

Step up the ladder when you need greater durability (reflective signs for outdoor) or formal lockout procedures (tags with signature fields). For simple indoor marking, adhesive labels suffice.

Why source from 3G Electric?

3G Electric interprets your requirement and supplies genuine industrial equipment, parts, and supplies across 14 industrial departments—far more than the 9 products listed in our catalogue. With over 35 years of experience, we specialize in combustion, pumps, and controls, but our breadth covers machining, electrical, power transmission, material handling, plumbing, HVAC, pneumatics, hydraulics, instrumentation, test & measurement, welding, lighting, and combustion systems. We offer quotes for parts beyond the catalogue and supply goods EXW Singapore (collection from our Singapore office). We do not offer installation or on-site technical help, but we can answer product questions from documentation.

OEM-attributed quote

According to Schneider Electric, “Relay Selection Guide” (2022): “When selecting a relay, always verify the coil voltage and frequency match the control circuit, and ensure the contact rating is suitable for the load type (resistive, inductive, or capacitive).”

FAQ

Q: What is the difference between 4P and 4PDT?
A: 4P means four poles; 4PDT means four poles, double-throw (each pole has normally open and normally closed contacts). 4PST has four poles, single-throw (only normally open or normally closed). Choose based on whether you need to switch between two circuits per pole.

Q: Can I use a 220 V relay in a 240 V system?
A: Yes, most 220 V AC relays are rated for 220–240 V AC and will operate safely at 240 V. However, check the coil insulation and tolerance; continuous overvoltage may reduce life.

Q: How do I select a relay for an International application with 50 Hz vs 60 Hz?
A: Choose a relay rated for both 50 Hz and 60 Hz. At 60 Hz, the coil impedance is higher, so pull-in current is lower; ensure the relay is not marginal. For critical applications, use a relay with a wide frequency range.

Q: Where can I buy 3G-OTH-42386 Relay, 4 P 220 V in International?
A: 3G Electric supplies industrial relays and safety accessories. Contact us for a quote; goods are offered EXW Singapore. We can also source parts beyond our catalogue.

Q: What safety labels are recommended for 220 V relay panels?
A: Use BRADY 220 V danger labels (e.g., Polyester Labels) for indoor panels, and lockout tags (e.g., Danger Tags) during maintenance.

Key takeaways

  • 3G-OTH-42386 Relay, 4 P 220 V is a four-pole control relay with a 220 V AC coil, used in panels and machinery.
  • Verify coil frequency (50/60 Hz), contact rating, and mounting style before ordering.
  • Pair with BRADY 220 V hazard labels and lockout tags for safety compliance.
  • 3G Electric supplies genuine industrial parts with EXW Singapore terms; contact for quotes.

Contact 3G Electric for a quote on 3G-OTH-42386 relays or safety accessories. We interpret your requirement and supply the right part—no installation or on-site help offered.

Frequently Asked Questions
What is a 3G-OTH-42386 Relay, 4 P 220 V used for?+
It is a four-pole control relay with a 220 V AC coil, used to switch multiple circuits in industrial panels, HVAC, and machinery. It allows a single control signal to operate up to four separate loads.
How do I choose between 4P and 4PDT relay?+
4P indicates four poles; 4PDT means each pole has both normally open and normally closed contacts. Choose 4PDT if you need to switch between two paths per pole; otherwise 4PST (single-throw) may suffice.
Can I use a 220 V relay in a 240 V system?+
Yes, most 220 V AC relays are rated for 220–240 V AC and will operate safely at 240 V. Check the coil tolerance and ensure continuous overvoltage does not exceed the relay’s rating.
Where to buy 3G-OTH-42386 Relay, 4 P 220 V in International?+
3G Electric supplies industrial relays and safety accessories. Contact us for a quote; goods are offered EXW Singapore. We can also source parts beyond our catalogue.
What safety labels are recommended for 220 V relay panels?+
Use BRADY 220 V danger labels for indoor panels, and lockout tags during maintenance. Products like the BRADY Polyester Labels (SKU 3G-OTH-702746) and Danger Tags (SKU 3G-OTH-703587) are suitable.
Recommended Hardware
Polyester adhesive signs for marking 220-volt electrical hazards. Each sign measures 3 1/2 in x 5 in with a thickness of 0.01 in. Pack of 5. Not retroreflective, not glow-in-the-dark, no anti-slip surface. Suitable for indoor use on clean, dry surfaces.
BRADY
Polyester adhesive signs for marking 220-volt electrical hazards. Each sign measures 3 1/2 in x 5 in with a thickness of 0.01 in. Pack of 5. Not retroreflective, not glow-in-the-dark, no anti-slip surface. Suitable for indoor use on clean, dry surfaces.
View Specifications
This 8-pack of adhesive-mounted signs warns personnel of 220-volt electrical hazards. Suitable for application on equipment, panels, or walls in industrial environments. Signs are not retroreflective, not glow-in-the-dark, and have no anti-slip surface.
BRADY
This 8-pack of adhesive-mounted signs warns personnel of 220-volt electrical hazards. Suitable for application on equipment, panels, or walls in industrial environments. Signs are not retroreflective, not glow-in-the-dark, and have no anti-slip surface.
View Specifications
Adhesive-mounted polyester labels for marking 220-volt hazards. Nominal size 3 1/2 in x 5 in, 0.01 in thick. Not retroreflective, non-glowing, non-slip. Suitable for indoor use on equipment, panels, or walls.
BRADY
Adhesive-mounted polyester labels for marking 220-volt hazards. Nominal size 3 1/2 in x 5 in, 0.01 in thick. Not retroreflective, non-glowing, non-slip. Suitable for indoor use on equipment, panels, or walls.
View Specifications
support_agent
Need Technical Assistance?
Our engineers are available for specialized consultations regarding complex equipment assemblies.
Contact Support