Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

3G Electric
Home›Resources›Honeywell VC4013 Valve Actuator Buyer's Guide: 6-Second, 6 VA, 200-240 VAC for Singapore

Honeywell VC4013 Valve Actuator Buyer's Guide: 6-Second, 6 VA, 200-240 VAC for Singapore

A practical Singapore buyer's guide to the Honeywell VC4013 6-second, 6 VA valve actuator — 200-240 VAC 50/60 Hz, IP40, double insulated — covering specs, selection criteria, compatible Honeywell accessories and sourcing from 3G Electric.
Publication Date6 October 2026 · 08:34 pm
Technical Reviewer3G Electric Technical Team
Honeywell VC4013 Valve Actuator Buyer's Guide: 6-Second, 6 VA, 200-240 VAC for Singapore
Controls
Table of Contentsexpand_more

The Honeywell VC4013 is a 6-second, 6 VA motorised valve actuator rated 200-240 VAC 50/60 Hz with IP40 protection and double insulation, designed to drive Honeywell T65 and TS110 series valves. In Singapore it is typically specified for 230 V/50 Hz single-phase HVAC, F&B and light process control loops where fast, repeatable on/off valve positioning is required.

What is a Honeywell VC4013 valve actuator?

A Honeywell VC4013 valve actuator is a compact electric motor unit that converts a 200-240 VAC control signal into a 6-second rotary or linear stroke to open and close a compatible Honeywell valve. It draws 6 VA, carries an IP40 enclosure rating and is double insulated, so no separate earth bonding is required at the actuator.

Honeywell is one of the most widely specified control brands in Singapore's building services and process industries, and the VC4013 sits in the same family as the T65 and TS110 valve ranges. Because it is double insulated and rated IP40, it is intended for indoor, dry control panels and plant rooms rather than washdown or outdoor marine decks.

Honeywell VC4013 specifications at a glance

ParameterValue
ModelHoneywell VC4013
Actuation time6 seconds (full stroke)
Power consumption6 VA
Supply voltage200-240 VAC
Frequency50/60 Hz
Compatible valve seriesT65, TS110
Enclosure ratingIP40
Insulation classDouble insulated
Typical dutyOn/off control, indoor mounting

Every value above is taken from the Honeywell VC4013 datasheet. If your application needs a different stroke time, voltage or IP rating, step to another actuator in the same Honeywell family rather than forcing the VC4013 into a duty it was not designed for.

How does a 6-second, 6 VA actuator work?

When 200-240 VAC is applied, the VC4013's synchronous motor drives the valve stem through a gear train to its end position in approximately 6 seconds. A return spring or reversing circuit (depending on the valve body) brings it back when power is removed or the control signal reverses.

The 6 VA coil is deliberately low-draw, which lets a single 230 V/50 Hz control circuit in a Singapore plant room feed multiple actuators without overloading the transformer. The 6-second stroke is fast enough for tight temperature control on fan coil units and small reheat coils, but not intended for high-cycle modulating duty.

Which Singapore applications suit the VC4013?

  • HVAC and chilled water: fan coil units, reheat coils and small AHU valves in commercial buildings running 230 V/50 Hz.
  • F&B and beverage plants: CIP-adjacent hot water and steam control where the actuator sits in a dry panel, not a washdown zone.
  • Pharmaceutical and precision manufacturing: clean, indoor process loops needing repeatable on/off valve positioning.
  • Marine and offshore support: accommodation and utility HVAC circuits — but only where the IP40 enclosure is protected from spray.

Singapore's humid tropical climate makes IP rating and corrosion resistance a real selection factor. IP40 protects against solid objects over 1 mm but not water, so mount the VC4013 inside a dry enclosure or plant room. For wet or outdoor locations, specify a higher IP-rated actuator instead.

How to select the right Honeywell valve actuator

  1. Match the valve series first. The VC4013 is built for Honeywell T65 and TS110 valves — confirm the valve body model before ordering.
  2. Confirm supply voltage and frequency. Singapore's single-phase supply is 230 V / 50 Hz, which sits inside the VC4013's 200-240 VAC 50/60 Hz window.
  3. Check stroke time against your control loop. 6 seconds suits on/off and slow modulating duty; fast modulating loops may need a shorter-stroke actuator.
  4. Verify the IP rating against the mounting location. IP40 is indoor/dry only — upgrade for washdown, outdoor or marine deck mounting.
  5. Size the control circuit for 6 VA per actuator. Add up total VA on the transformer or controller output before adding more units.
  6. Plan for spares. Keep at least one spare actuator per critical loop — Singapore's fast local delivery from 3G Electric stock shortens unplanned downtime.

Actuators rarely fail alone — the recorder or controller logging the loop often needs consumables at the same time. 3G Electric stocks Honeywell circular chart paper for the most common temperature recorders used alongside VC4013-controlled loops in Singapore plants.

ProductCompatibilityRangePack
Honeywell Circular Paper Chart 0°C to 300°C for DR 4311Honeywell DR 4311 recorder0°C to 300°C100 charts
Honeywell Circular Paper Chart 0°F to 400°F for AR-100Honeywell AR-100 recorder0°F to 400°F100 charts
Honeywell Circular Paper Chart 11.88 in for DR 4500 TrulineHoneywell DR 4500 Truline11.88 in diameter100 charts
Honeywell Circular Paper Chart 0°F to 2,000°F for AR-100Honeywell AR-100 recorder0°F to 2,000°F100 charts
Honeywell Circular Paper Chart -85°C to 190°C for AR-100Honeywell AR-100 recorder-85°C to 190°C100 charts

Step up the ladder when your loop needs a wider temperature range, a different recorder platform, or a higher-IP actuator. If you are running a DR 4500 Truline, the 11.88-inch chart is the correct consumable; for AR-100 installations, choose the chart range that brackets your process temperature.

Why source the Honeywell VC4013 from 3G Electric in Singapore?

3G Electric is a Singapore-based industrial distributor with 35+ years of experience interpreting customer demand and delivering genuine industrial equipment, parts and supplies. We stock 51 products in related categories and supply far more than is listed online — across 14 industrial departments including controls, combustion, pumps, instrumentation and measurement.

Our specialist depth in combustion, pumps and controls means we can help you confirm valve series, stroke time and control-circuit VA before you commit to an order. For Singapore buyers, that translates to fast local delivery, technical support in your time zone, and a single accountable point of contact for Honeywell actuators and recorder consumables.

Frequently asked questions

What voltage does the Honeywell VC4013 require?
The VC4013 is rated 200-240 VAC at 50/60 Hz, which matches Singapore's 230 V / 50 Hz single-phase supply. It draws 6 VA and completes a full stroke in approximately 6 seconds. Confirm your control circuit can supply the total VA of all actuators on the loop.

Which Honeywell valves does the VC4013 fit?
The VC4013 is designed for Honeywell T65 and TS110 series valves. Always confirm the valve body model and stroke direction before ordering, because fitting the wrong actuator can damage the valve stem or leave the loop stuck in one position.

Is the VC4013 suitable for outdoor or washdown areas in Singapore?
No. The VC4013 carries an IP40 rating, which protects against solid objects over 1 mm but not water ingress. In Singapore's humid, high-rainfall climate, mount it inside a dry plant room or control enclosure, or specify a higher-IP actuator for outdoor and washdown locations.

How fast is the 6-second stroke, and what duty suits it?
A 6-second full stroke suits on/off control and slow modulating loops such as fan coil units and small reheat coils. It is not intended for high-cycle fast modulating duty. If your loop demands faster response, choose a shorter-stroke actuator from the same Honeywell family.

How quickly can 3G Electric deliver a Honeywell VC4013 in Singapore?
3G Electric holds Singapore stock and provides fast local delivery for in-stock items, with technical support to confirm compatibility before dispatch. Contact us with your valve model, supply voltage and required quantity for a same-day quote and lead time.

What does double insulated mean on the VC4013?
Double insulation means the actuator has two independent layers of insulation between live parts and the user, so it does not require a separate protective earth connection. This simplifies wiring in 230 V / 50 Hz Singapore control panels and reduces installation time.

Key takeaways

  • The Honeywell VC4013 is a 6-second, 6 VA actuator rated 200-240 VAC 50/60 Hz, IP40, double insulated, for T65 and TS110 valves.
  • It suits indoor 230 V / 50 Hz Singapore HVAC, F&B and light process loops — not washdown or outdoor mounting.
  • Confirm valve series, stroke time, IP rating and total control-circuit VA before ordering.
  • Pair it with the correct Honeywell circular chart paper for your recorder to keep the whole loop documented.
  • 3G Electric stocks 51+ related products and offers fast Singapore delivery plus technical support across 14 industrial departments.

Ready to specify or replace a Honeywell VC4013? Contact 3G Electric for a quote, sizing assistance and technical support — send us your valve model, supply voltage and quantity, and we will confirm compatibility and Singapore lead time.

Frequently Asked Questions
What voltage does the Honeywell VC4013 require?+
The VC4013 is rated 200-240 VAC at 50/60 Hz, which matches Singapore's 230 V / 50 Hz single-phase supply. It draws 6 VA and completes a full stroke in approximately 6 seconds. Confirm your control circuit can supply the total VA of all actuators on the loop.
Which Honeywell valves does the VC4013 fit?+
The VC4013 is designed for Honeywell T65 and TS110 series valves. Always confirm the valve body model and stroke direction before ordering, because fitting the wrong actuator can damage the valve stem or leave the loop stuck in one position.
Is the VC4013 suitable for outdoor or washdown areas in Singapore?+
No. The VC4013 carries an IP40 rating, which protects against solid objects over 1 mm but not water ingress. In Singapore's humid, high-rainfall climate, mount it inside a dry plant room or control enclosure, or specify a higher-IP actuator for outdoor and washdown locations.
How fast is the 6-second stroke, and what duty suits it?+
A 6-second full stroke suits on/off control and slow modulating loops such as fan coil units and small reheat coils. It is not intended for high-cycle fast modulating duty. If your loop demands faster response, choose a shorter-stroke actuator from the same Honeywell family.
How quickly can 3G Electric deliver a Honeywell VC4013 in Singapore?+
3G Electric holds Singapore stock and provides fast local delivery for in-stock items, with technical support to confirm compatibility before dispatch. Contact us with your valve model, supply voltage and required quantity for a same-day quote and lead time.
What does double insulated mean on the VC4013?+
Double insulation means the actuator has two independent layers of insulation between live parts and the user, so it does not require a separate protective earth connection. This simplifies wiring in 230 V / 50 Hz Singapore control panels and reduces installation time.