Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

3G Electric
Bacharach logo

Bacharach

USAMeasurement & Detection

Bacharach is a manufacturer of gas detection and combustion analysis instrumentation, with a product line that spans portable combustible gas detectors, carbon monoxide sensors, refrigerant monitors, and the supporting consumables—filters, measurement liquids, and calibration accessories—required to keep those instruments operational in the field. The brand's catalog is oriented toward practical, field-deployable measurement tools rather than fixed-installation systems. Its instruments are designed for technicians and engineers who need to verify burner performance, detect gas leaks, and assess combustion efficiency on-site, without relying on mains power or wireless connectivity. The product range includes full-size and portable combustible gas detectors with detection thresholds specified in parts per million (e.g., 20–500 ppm for methane), carbon monoxide sensors compatible with specific analyzer models, and replacement filter packs and charcoal filter assemblies that maintain the accuracy of gas detection and refrigerant monitoring equipment. Bacharach also produces manual sampling instruments for smoke and opacity measurement, including a comparison smoke scale with a 10-spot oil burner reference and an opacity meter kit certified to TÜV and compliant with DIN 51402, a European standard for measuring smoke density from oil burners. These instruments are specified with concrete operating parameters: pump stroke durations measured in seconds (e.g., 3 seconds per piston stroke), sampling tube geometries (9/32-inch hole diameter, minimum 2.5-inch insertion depth), and repeatable measurement cycles (typically 10 or 15 pump strokes per sample). The brand's equipment is built for environments where portability, durability, and accuracy are paramount—typical of industrial plant floors, service vehicle kits, and field laboratories. Bacharach's consumables, such as CO₂ measurement liquid and replacement filters, are designed to integrate seamlessly with their analyzers and detectors, ensuring that maintenance cycles are straightforward and that instruments remain within specification over time. 3G Electric supplies Bacharach's gas detection and combustion analysis line, including portable detectors, sensors, filters, and manual sampling kits, to support plant engineers and maintenance managers who require reliable, verifiable measurement tools for combustion tuning, leak detection, and emissions monitoring. The product range is selected to cover both the instruments themselves and the spare parts needed for ongoing service, allowing procurement specialists to source complete solutions from a single catalog entry.

Genuine
OEM Parts
Expert
Tech Support
1 Day
Quote Response
USA
Origin
Worldwide Shipping
Air & sea freight
Datasheets on Request
Technical specs & drawings
1-Day Quote Response
Singapore-based team
Browse:
Show
Page 1 of 2
← Prev12Next →

About Bacharach

Bacharach is a manufacturer of gas detection and combustion analysis instrumentation, with a product line that spans portable combustible gas detectors, carbon monoxide sensors, refrigerant monitors, and the supporting consumables—filters, measurement liquids, and calibration accessories—required to keep those instruments operational in the field. The brand's catalog is oriented toward practical, field-deployable measurement tools rather than fixed-installation systems. Its instruments are designed for technicians and engineers who need to verify burner performance, detect gas leaks, and assess combustion efficiency on-site, without relying on mains power or wireless connectivity. The product range includes full-size and portable combustible gas detectors with detection thresholds specified in parts per million (e.g., 20–500 ppm for methane), carbon monoxide sensors compatible with specific analyzer models, and replacement filter packs and charcoal filter assemblies that maintain the accuracy of gas detection and refrigerant monitoring equipment. Bacharach also produces manual sampling instruments for smoke and opacity measurement, including a comparison smoke scale with a 10-spot oil burner reference and an opacity meter kit certified to TÜV and compliant with DIN 51402, a European standard for measuring smoke density from oil burners. These instruments are specified with concrete operating parameters: pump stroke durations measured in seconds (e.g., 3 seconds per piston stroke), sampling tube geometries (9/32-inch hole diameter, minimum 2.5-inch insertion depth), and repeatable measurement cycles (typically 10 or 15 pump strokes per sample). The brand's equipment is built for environments where portability, durability, and accuracy are paramount—typical of industrial plant floors, service vehicle kits, and field laboratories. Bacharach's consumables, such as CO₂ measurement liquid and replacement filters, are designed to integrate seamlessly with their analyzers and detectors, ensuring that maintenance cycles are straightforward and that instruments remain within specification over time. 3G Electric supplies Bacharach's gas detection and combustion analysis line, including portable detectors, sensors, filters, and manual sampling kits, to support plant engineers and maintenance managers who require reliable, verifiable measurement tools for combustion tuning, leak detection, and emissions monitoring. The product range is selected to cover both the instruments themselves and the spare parts needed for ongoing service, allowing procurement specialists to source complete solutions from a single catalog entry.

Common Applications

  • Industrial burner maintenance — Bacharach comparison smoke scale (BAC10018) for visual smoke density assessment
  • HVAC commissioning — Bacharach combustible gas detector (19-7075) for methane leak detection in refrigerant lines
  • Emissions monitoring — Bacharach opacity meter kit (BAC05010) for measuring particulate opacity in exhaust stacks
  • Plant safety monitoring — Bacharach combustible gas detector (19-8038) with refrigerant and combustible gas sensors for leak location
  • Field service laboratories — Bacharach CO₂ measurement liquid (BAC10068) for wet-chemical analysis of combustion gases
  • Refrigerant leak detection — Bacharach charcoal filter assembly (3015-3125) for portable area gas monitors
Origin: Manufactured in USA

Related brands we carry

Comparable manufacturers in the same product category.

Frequently asked questions

Common questions about Bacharach from 3G Electric.

What is the detection range of the Bacharach combustible gas detector model 19-7075?

The Bacharach combustible gas detector (MPN 19-7075) has a detection range of 20 to 500 ppm for methane. It features a sound alert to notify the user when gas is detected within that range. The detector is portable and includes a soft carrying case for field use. This range is suitable for locating gas leaks in industrial environments where methane concentrations may vary, and the sound alert provides an immediate indication without requiring visual confirmation, which is useful in low-light or obstructed areas.

How does the Bacharach comparison smoke scale (BAC10018) work?

The Bacharach comparison smoke scale (BAC10018) is a manual gas detection instrument that uses a 10-spot oil burner smoke scale for visual assessment of smoke density. To operate, a sample pump must deliver 10 full strokes, with each stroke drawing a fixed volume of exhaust gas through a sampling tube. The sampling tube has a hole diameter of 9/32 inch and must be inserted at least 2.5 inches into the stack. After sampling, the filter is compared against the 10-spot scale to determine the smoke number. Additional sample pump strokes (10 or 15) may be required for repeat measurements, and the pump requires 1/4 fluid ounce of lubricant for proper operation.

What certifications does the Bacharach opacity meter kit (BAC05010) hold?

The Bacharach opacity meter kit (BAC05010) is TÜV approved and compliant with DIN 51402, a European standard for measuring smoke density from oil burners. The kit requires 10 complete sampling pump strokes per measurement, with each piston stroke lasting 3 seconds. A total of 3 measurements are required to obtain a reliable opacity reading. These specifications ensure that the instrument provides repeatable results in field conditions, and the TÜV certification indicates that the device meets specific safety and performance criteria recognized in European industrial applications.

What is the purpose of the Bacharach replacement filter pack (19-0509)?

The Bacharach replacement filter pack (SKU 19-0509) contains 5 filters designed for use with the Bacharach combustible gas detector model 2XFE4 (MPN 19-8038). These filters replace worn or contaminated filters in the detector to maintain accurate gas detection. Over time, filters can become clogged with particulates or absorb contaminants, which can reduce the sensor's responsiveness and lead to false readings. Regular replacement of these filters is a standard maintenance task to ensure the detector continues to operate within its specified detection range and provides reliable readings in HVAC, combustion, and safety monitoring applications.

Which Bacharach carbon monoxide sensor is compatible with analyzer model 0019-9376?

The Bacharach carbon monoxide sensor (MPN 0024-1795) is designed for use with carbon monoxide analyzers and is compatible with manufacturer model number 0019-9376. This sensor is a replacement part that monitors CO levels in combustion, HVAC, and plant maintenance applications. When installing the sensor, it is important to verify that the analyzer model matches the compatibility list to ensure proper function. The sensor is a critical component for accurate CO measurement, and replacing it according to the manufacturer's recommended schedule helps maintain the analyzer's performance and compliance with safety standards.

What is the function of the Bacharach charcoal filter assembly (3015-3125)?

The Bacharach charcoal filter assembly (SKU 3015-3125) is designed for use with the Bacharach Portable Area Gas Refrigerant Monitor. Its function is to remove contaminants from the sampled gas before it reaches the sensor, ensuring accurate refrigerant leak detection. The charcoal filter absorbs impurities that could otherwise interfere with the sensor's readings or cause premature wear. By maintaining the filter, the monitor's lifespan is extended, and the risk of false alarms or missed leaks is reduced. This filter is a consumable item that should be replaced periodically based on usage and environmental conditions.