IEC
Frequently asked questions
Common questions about IEC from 3G Electric.
What are the key specifications of the IEC FAZ-C20/4-NA miniature circuit breaker?
The IEC FAZ-C20/4-NA is a 4-pole, C-curve miniature circuit breaker rated 20 A at 277/480V AC. It has a UL489 listing for branch-circuit protection and a 10 kA interrupting capacity. It is designed for DIN rail mounting and uses screw-type terminals. The C-curve trip characteristic is suitable for inductive loads with moderate inrush currents. This model is part of the FAZ series and is identified by manufacturer part number FAZ-C20/4-NA. When specifying, confirm the voltage and current ratings match your application requirements.
What residual current options are available in the IEC GFP series ground fault protectors?
The IEC GFP series includes ground fault protectors with rated residual currents of 26 mA, 86 mA, and 260 mA. These thresholds determine the sensitivity of ground fault detection. Lower values like 26 mA provide more sensitive protection, while 260 mA is less sensitive and may be used for equipment protection. The GFP series also offers current ratings of 25 A, 40 A, and 63 A, with voltage ratings of 240V AC or 277V AC. Maximum interrupting ratings are either 1.5 kA or 10 kA at 240V AC. All models have Type A curve characteristics and are UL1053 listed for DIN rail mounting.
What is the difference between the IEC FAZ series and GFP series?
The IEC FAZ series consists of miniature circuit breakers (MCBs) designed for overcurrent protection, such as the FAZ-C20/4-NA. The GFP series consists of ground fault protectors that detect and interrupt ground faults. Both are DIN rail-mount devices, but they serve different protective functions. FAZ MCBs are UL489 listed, while GFP devices are UL1053 listed. The FAZ series is available in C-curve, 4-pole configurations, while the GFP series offers various current and residual current ratings. In a panel, they may be used together to provide both overcurrent and ground fault protection.
What are the voltage and interrupting ratings of IEC GFP series models?
IEC GFP series ground fault protectors are available with voltage ratings of 240V AC or 277V AC. The maximum interrupting rating is either 1.5 kA or 10 kA at 240V AC, depending on the model. For example, SKU 482N48 is rated 40 A at 240V AC with 260 mA residual current and 1.5 kA interrupting capacity. SKU 482N38 is rated 25 A at 277V AC with 26 mA residual current and 10 kA interrupting capacity. Always verify the specific SKU's ratings to ensure compatibility with your system's available fault current and voltage.
Are IEC miniature circuit breakers and ground fault protectors UL listed?
Yes, the IEC FAZ series miniature circuit breakers are UL489 listed for branch-circuit protection. The GFP series ground fault protectors are UL1053 listed. These listings indicate compliance with applicable UL standards for the respective product categories. UL489 covers molded-case circuit breakers and circuit breakers for panelboards, while UL1053 covers ground fault sensing and relaying equipment. When specifying, confirm that the UL listing matches the requirements of your installation and local electrical codes. The listings are a key consideration for acceptance by authorities having jurisdiction.
What mounting and terminal types do IEC FAZ and GFP series devices use?
Both the IEC FAZ series miniature circuit breakers and GFP series ground fault protectors are designed for DIN rail mounting, which is standard in industrial control panels. The FAZ series MCBs use screw-type terminals for wire connections. The GFP series also uses screw-type terminals, though specific terminal details may vary by model. DIN rail mounting allows for easy installation and replacement in standard enclosures. When planning a panel, ensure the DIN rail type and terminal wire size are compatible with the device specifications. Refer to the individual SKU documentation for terminal torque and wire range details.