JOHNSON CONTROLS
Guides & Resources
- Controls & Safety: A Procurement Engineer's Guide to Specifying and Sourcing Industrial Valve and Relay Systems
- Burners & Combustion: Upgrading Legacy Systems to Modern Control Standards for HVAC Contractors
- Controls & Safety: Installation, Wiring, and Commissioning Best Practices for HVAC Contractors in Singapore
Frequently asked questions
Common questions about JOHNSON CONTROLS from 3G Electric.
What are the key specifications of Johnson Controls TE-6361M-1 duct temperature sensor?
The TE-6361M-1 is a hardwired duct temperature sensor with a metal conduit box housing. It features averaging measurement, a temperature range of 32°F to 158°F, and accuracy of ±0.34°F. It includes two hex-head self-drilling screws for installation. The sensor is designed for duct-mount installation in building automation systems. The housing is metal, and it has no display. This sensor is suitable for monitoring duct temperatures in HVAC applications.
What is the difference between Johnson Controls SEC99AA-24C and SEC99AB-60C capillary tubing?
The SEC99AA-24C is a 24-inch armored capillary tubing with a 1/4 inch straight connection and a control side depressor. The SEC99AB-60C is a 60-inch armored capillary tubing with a 1/4 inch connection featuring a 90° elbow and both control side and equipment side depressors. Both have a 0.06 inch inner diameter and are used to connect pressure controls in refrigeration systems. They are UL Recognized (SA9457) and have CCN SFCS2 and SFCS8 standards.
What are the electrical ratings for Johnson Controls P74EA-8C differential pressure control?
The P74EA-8C differential pressure control has SPDT switch action that opens and closes on both rise and fall of differential pressure. It is rated for 208V/240V with automatic reset and a setpoint of 3.5 psi. The overall depth is 2-1/16 inches and width is 4 inches. It is used in applications requiring differential pressure control, such as in HVAC systems. The switch action allows for control of equipment based on pressure changes.
What are the construction details of Johnson Controls F261MAH-V01C flow switch?
The F261MAH-V01C is an insertion-style paddle flow switch for liquid flow detection. It has a stainless steel construction with a 1 inch NPT connection and is designed for 3 inch pipe size. The contact rating is 16 A @ 120V (Full Load). It is used in piping systems to detect liquid flow. The switch is suitable for applications where flow verification is required, such as in hydronic systems or process piping.
What is the flow rating and connection type for Johnson Controls VG2431YN globe valve?
The VG2431YN is a 2-way flanged connection globe valve with a cast iron body, stainless steel stem, and brass seat. It has a 350 CV flow rating and 6-inch flanged connections. The valve action is normally closed, stem-up-to-close. It is used in hydronic heating and cooling systems. The cast iron body provides durability, and the stainless steel stem and brass seat offer corrosion resistance. The flanged connections allow for secure installation in piping systems.
What are the operating parameters of Johnson Controls P66AAB-1C fan speed control?
The P66AAB-1C is a refrigerant actuated electronic fan speed control with a 190 psig to 250 psig pressure sensor. It operates on 208 to 480V AC with 8 A output. It is designed for ambient temperatures from -40°F to 130°F. It is used to control fan speed in refrigeration systems based on refrigerant pressure. The control helps maintain condensing pressure by modulating fan speed, which can improve energy efficiency.