PASS
Frequently asked questions
Common questions about PASS from 3G Electric.
What is the difference between PASS & Seymour hospital-grade and general-purpose receptacles?
Hospital-grade PASS & Seymour receptacles are manufactured to meet UL 498 and Federal Specification WC-596 performance standards, which include higher abuse resistance and a minimum 1,000-cycle endurance test. They are typically identified by a green dot on the face or a specific catalog number. General-purpose receptacles meet UL 498 but are not subjected to the same high-abuse testing. In healthcare facilities, hospital-grade devices are often required by code for patient care areas. Both types are available in 125 V AC, 20 A, NEMA 5-20R configurations. The choice depends on the installation environment and local code requirements.
Does the PASS & Seymour DSW-301-B occupancy sensor require a neutral wire?
No, the PASS & Seymour DSW-301-B wall-switch occupancy sensor does not require a neutral connection. It operates at 120 V AC or 277 V AC and uses passive infrared and ultrasonic technology to detect occupancy. The sensor is designed for wall-switch replacement and includes a nightlight feature. Because it does not need a neutral, it can be used in older wiring systems where a neutral is not available at the switch box. However, it does require a ground connection for proper operation. Installation should be performed by a qualified electrician in accordance with local codes.
What does isolated ground mean on a PASS & Seymour receptacle?
An isolated ground receptacle, such as the PASS & Seymour 2097TRWRW, has a grounding terminal that is electrically isolated from the mounting yoke and the outlet box. This provides a dedicated ground path back to the service panel, which can reduce electrical noise on the ground circuit. Isolated ground receptacles are often used in healthcare, laboratory, and data-processing areas where sensitive equipment is present. The receptacle still includes a standard grounding pin, but the ground path is separated from the building's structural ground. The isolated ground conductor must be run separately to the panel. These devices are typically identified by an orange triangle on the face.
Are PASS & Seymour GFCI receptacles available in hospital-grade versions?
Yes, PASS & Seymour offers hospital-grade GFCI receptacles, such as the 2097HGTRPIW. This device combines ground-fault circuit interrupter protection with hospital-grade construction, meaning it meets the higher durability and performance standards required for healthcare environments. It is rated 125 V AC, 20 A, NEMA 5-20R, and includes tamper-resistant shutters. The GFCI function protects personnel from ground faults, while the hospital-grade rating ensures the device can withstand frequent use and abuse. These receptacles are typically used in patient care areas, kitchens, and other locations where both GFCI protection and hospital-grade reliability are required.
What NEMA configuration is used on PASS & Seymour 20 A receptacles?
PASS & Seymour 20 A, 125 V AC receptacles use the NEMA 5-20R configuration. This is a 2-pole, 3-wire grounding receptacle with a 20 A rating. The 5-20R has a T-shaped neutral slot, which distinguishes it from the 15 A 5-15R configuration. The 5-20R accepts both 15 A and 20 A plugs, but a 20 A plug cannot be inserted into a 15 A receptacle. Many PASS & Seymour models, including the PTTR63HRED and PT8300GRY, are 5-20R. When replacing a receptacle, the branch circuit must be rated for 20 A and wired with appropriate conductors. Always verify the circuit rating before installation.
How does 3G Electric support procurement of PASS & Seymour products?
3G Electric supplies PASS & Seymour wiring devices by manufacturer part number. The catalog lists key specifications such as voltage, amperage, NEMA configuration, color, and grade. Buyers can request a quote for specific SKUs, and 3G Electric will confirm availability, lead time, and pricing. For international orders, 3G Electric coordinates export documentation and shipping. The company does not manufacture or alter the products; it sources new OEM devices from authorized channels. If a required part number is not listed, 3G Electric can attempt to source it through its supplier network. Technical documentation and spec sheets are available upon request to assist with specification matching.