Send a part number, a photo, or a whole BOM — we supply it and stand behind it. EXW Singapore — collect from our office.

3G Electric

TRIPP LITE UPS

Tripp Lite is a manufacturer of power protection and connectivity equipment, with a product history dating back to 1922. The company's UPS line spans standby, line-interactive, and online double-conversion topologies, covering capacities from small desktop units to large three-phase systems. Tripp Lite UPS products are used in applications where equipment must ride through outages, brownouts, and transient disturbances: network closets, server rooms, industrial control panels, security systems, and telecommunications installations. The product families include SmartPro, SmartOnline, OmniVS, and Internet Office series, along with a range of external battery packs that extend runtime for compatible UPS models. 3G Electric supplies Tripp Lite UPS systems and batteries to technical buyers who need to match a UPS to a specific load profile, input voltage, and runtime requirement. The catalog includes standby UPS systems such as the INTERNET750U, rated 750 VA with 120 V AC input and selectable 110/115/120 V AC output, intended for home office equipment, network devices, and point-of-sale terminals. For longer runtime, 3G Electric stocks external battery packs including the BP36V42-3U (36 V DC, 56 Ah, detachable cable, compatible with SMART1500RMXL2UA), BP36V15-2U (36 V DC, 18 Ah, attached cable, compatible with SMART1000RMXL2U), BP48V48RT4U (48 V DC, 42 Ah, attached cable, compatible with SMART3000CRMXL), BP192V12-3U (192 V DC, 12 Ah, detachable cable, compatible with SU6000RT4UHVHW), BP48V60RT3UTAA (48 V DC, 42 Ah, attached cable, compatible with SMART5000RT3U), BP24V15RT2U (24 V DC, 14 Ah, attached cable, compatible with OMNIVS1500XL), and BP24V70-3U (24 V DC, 70 Ah, attached cable, compatible with OMNIVSINT1500XL). These battery packs are designed to be matched to specific UPS models; compatibility is determined by DC voltage, connector type, and the UPS's charging circuit. When specifying a Tripp Lite UPS, engineers typically evaluate topology (standby, line-interactive, or online double-conversion), VA/W rating, input voltage range, output voltage configuration, receptacle type and count, form factor (tower, rackmount, or rack/tower convertible), and communication options such as USB, RS-232, or SNMP. External battery packs are selected based on the desired runtime at a given load, the DC bus voltage required by the UPS, and the physical space available. 3G Electric supports the Tripp Lite line by stocking UPS systems and matching battery packs, providing manufacturer part numbers and compatibility data, and coordinating logistics for international delivery. The company serves plant engineers, maintenance managers, and procurement specialists who need to source power protection equipment with verifiable specifications and without channel restrictions.

Genuine
OEM Parts
Expert
Tech Support
1 Day
Quote Response
EXW
Singapore
EXW Singapore
Collect or forward from our office
Datasheets on Request
Technical specs & drawings
1-Day Quote Response
Singapore-based team
Browse:
Show
Page 1 of 4
← Prev1234Next →

About TRIPP LITE UPS

Tripp Lite is a manufacturer of power protection and connectivity equipment, with a product history dating back to 1922. The company's UPS line spans standby, line-interactive, and online double-conversion topologies, covering capacities from small desktop units to large three-phase systems. Tripp Lite UPS products are used in applications where equipment must ride through outages, brownouts, and transient disturbances: network closets, server rooms, industrial control panels, security systems, and telecommunications installations. The product families include SmartPro, SmartOnline, OmniVS, and Internet Office series, along with a range of external battery packs that extend runtime for compatible UPS models. 3G Electric supplies Tripp Lite UPS systems and batteries to technical buyers who need to match a UPS to a specific load profile, input voltage, and runtime requirement. The catalog includes standby UPS systems such as the INTERNET750U, rated 750 VA with 120 V AC input and selectable 110/115/120 V AC output, intended for home office equipment, network devices, and point-of-sale terminals. For longer runtime, 3G Electric stocks external battery packs including the BP36V42-3U (36 V DC, 56 Ah, detachable cable, compatible with SMART1500RMXL2UA), BP36V15-2U (36 V DC, 18 Ah, attached cable, compatible with SMART1000RMXL2U), BP48V48RT4U (48 V DC, 42 Ah, attached cable, compatible with SMART3000CRMXL), BP192V12-3U (192 V DC, 12 Ah, detachable cable, compatible with SU6000RT4UHVHW), BP48V60RT3UTAA (48 V DC, 42 Ah, attached cable, compatible with SMART5000RT3U), BP24V15RT2U (24 V DC, 14 Ah, attached cable, compatible with OMNIVS1500XL), and BP24V70-3U (24 V DC, 70 Ah, attached cable, compatible with OMNIVSINT1500XL). These battery packs are designed to be matched to specific UPS models; compatibility is determined by DC voltage, connector type, and the UPS's charging circuit. When specifying a Tripp Lite UPS, engineers typically evaluate topology (standby, line-interactive, or online double-conversion), VA/W rating, input voltage range, output voltage configuration, receptacle type and count, form factor (tower, rackmount, or rack/tower convertible), and communication options such as USB, RS-232, or SNMP. External battery packs are selected based on the desired runtime at a given load, the DC bus voltage required by the UPS, and the physical space available. 3G Electric supports the Tripp Lite line by stocking UPS systems and matching battery packs, providing manufacturer part numbers and compatibility data, and coordinating logistics for international delivery. The company serves plant engineers, maintenance managers, and procurement specialists who need to source power protection equipment with verifiable specifications and without channel restrictions.

Common Applications

  • Network closets — Tripp Lite SMART1500RMXL2UA UPS with BP36V42-3U external battery for extended runtime of switches and routers.
  • Server rooms — Tripp Lite SMART3000CRMXL UPS with BP48V48RT4U battery pack to support rackmount servers during outages.
  • Industrial control panels — Tripp Lite OMNIVS1500XL UPS with BP24V15RT2U battery for PLC and HMI backup.
  • Telecommunications — Tripp Lite SU6000RT4UHVHW UPS with BP192V12-3U battery for high-voltage DC bus runtime extension.
  • Point-of-sale systems — Tripp Lite INTERNET750U standby UPS for cash registers and payment terminals.
  • Security systems — Tripp Lite SMART1000RMXL2U UPS with BP36V15-2U battery for cameras and access control.

Frequently asked questions

Common questions about TRIPP LITE UPS from 3G Electric.

What is the difference between Tripp Lite standby and online double-conversion UPS systems?

Standby UPS systems, such as the INTERNET750U, pass utility power directly to the load and switch to battery-backed inverter output when input voltage falls outside a threshold. They provide surge protection and brief ride-through but do not correct voltage or frequency continuously. Online double-conversion UPS systems rectify incoming AC to DC and then invert it back to AC, isolating the load from input disturbances and providing zero transfer time. Online units are typically used for sensitive equipment where frequency regulation and continuous voltage conditioning are required. Selection depends on the load's tolerance for transfer time and input voltage variation.

How do I choose an external battery pack for a Tripp Lite UPS?

Match the battery pack to the UPS by DC voltage, connector type, and manufacturer compatibility. For example, the BP36V42-3U is a 36 V DC, 56 Ah pack with a detachable cable, compatible with the SMART1500RMXL2UA. The BP48V48RT4U is a 48 V DC, 42 Ah pack with an attached cable, compatible with the SMART3000CRMXL. Using a pack with the wrong voltage or connector can damage the UPS or the battery. Runtime at a given load depends on the pack's amp-hour capacity and the UPS's inverter efficiency. Consult the UPS model's specifications for approved external battery packs.

What VA rating should I select for a Tripp Lite UPS?

Sum the wattage of all connected equipment, then divide by the UPS power factor to estimate the required VA. Tripp Lite UPS systems are rated in VA and watts; the watt rating is the real power limit. For example, a 750 VA standby UPS may have a watt rating around 450 W. Leave headroom for future additions and for equipment with high inrush current, such as motors or laser printers. If the load includes power-factor-corrected supplies, the VA and watt ratings may be closer. Verify the UPS's output waveform (sine wave or simulated sine wave) is compatible with the connected equipment.

Are Tripp Lite UPS batteries user-replaceable?

Many Tripp Lite UPS systems use internal batteries that can be replaced in the field, and external battery packs are designed for connection to compatible UPS models. Replacement intervals depend on ambient temperature, discharge cycles, and charging conditions. Tripp Lite publishes battery replacement part numbers for each UPS model. For external packs, the connection type (attached or detachable cable) and DC voltage must match the UPS. Always follow the manufacturer's safety instructions when replacing batteries, and dispose of used batteries according to local regulations.

What communication options are available on Tripp Lite UPS systems?

Tripp Lite UPS systems may include USB, RS-232 serial, and dry-contact relay ports, depending on the model. Some models support an optional SNMP card for network management. These interfaces allow monitoring of input voltage, output voltage, load level, battery status, and event logs. For industrial control or building management systems, dry-contact outputs can signal alarm conditions. The specific communication features vary by product family and model; verify the specifications for the exact SKU before specifying integration with a monitoring system.

Can Tripp Lite UPS systems be used in industrial environments?

Tripp Lite UPS systems are used in industrial settings where equipment requires protection from power disturbances. Selection criteria include the operating temperature range, enclosure type, and mounting method. Many models are designed for rackmount or tower installation in controlled environments such as control rooms or network closets. For harsh environments, the UPS may need to be installed in a protective enclosure. Verify the UPS's environmental specifications, including operating temperature and humidity, against the installation site conditions. External battery packs should also be evaluated for their operating temperature range and ventilation requirements.