WIKA
Frequently asked questions
Common questions about WIKA from 3G Electric.
What is the pressure range and output of the WIKA E-10 pressure transmitter?
The WIKA E-10 series includes models with pressure ranges from 0–30 psi up to 0–3,000 psi. Output signals are either 5V or 20mA, with accuracy of ±0.5% of span. For example, SKU 412PA2 covers 1–30 psi with a 20mA output, while SKU 412PE7 covers 0–1,000 psi with a 5V output. All E-10 transmitters feature a stainless steel housing, IP67 and NEMA 4X ratings, and a 1/2" NPT male conduit connection with free ends. They require 30V DC power and have specific overpressure and burst pressure ratings depending on the range.
What are the wetted materials and connection sizes for the WIKA 233.50.100 pressure gauge?
The WIKA 233.50.100 is a 100 mm (4") pressure gauge with a 0–16 bar range. It has a 316 stainless steel case and wetted parts, silicone oil filling, and shatterproof safety glass. The process connection is 1/2" NPT male, bottom-mounted. This gauge is suitable for applications requiring local pressure indication in corrosive environments or where vibration and pulsation are present, thanks to the liquid filling. It is part of WIKA's 233.50 series of stainless steel gauges.
Are WIKA E-10 transmitters suitable for outdoor or washdown environments?
Yes, WIKA E-10 transmitters are rated IP67 and NEMA 4X, which means they are protected against dust ingress and water immersion up to 1 meter for 30 minutes, as well as corrosion and hose-directed water. This makes them suitable for outdoor installations, washdown areas, and other harsh environments. The stainless steel housing further enhances durability. However, for applications requiring explosion protection, additional approvals may be necessary; consult the specific model's datasheet for details.
What is the difference between the 5V and 20mA output options on WIKA E-10 transmitters?
The 5V output provides a voltage signal proportional to pressure, typically used for short-distance transmission to controllers or data loggers. The 20mA output is a current loop signal, which is less susceptible to electrical noise and voltage drops, making it suitable for long-distance transmission in industrial environments. Both output types offer ±0.5% accuracy. The choice depends on the input requirements of your receiving device and the distance between the transmitter and the control system. 3G Electric stocks both variants, such as SKU 412PF1 (5V) and SKU 412PA2 (20mA).
Can 3G Electric provide WIKA products with hazardous area approvals?
WIKA offers many instruments with ATEX, IECEx, or other hazardous area approvals. While the current 3G Electric inventory of 31 SKUs may not list all approval variants, 3G Electric can source specific WIKA models with the required certifications upon request. Provide the exact model number, approval type, and application details, and 3G Electric will coordinate with WIKA to fulfill the order. Always verify that the selected product carries the appropriate approval for your installation.
What is the overpressure rating of the WIKA E-10 transmitter with 0–1,000 psi range?
The WIKA E-10 transmitter with 0–1,000 psi range (e.g., SKU 412PE7) has an overpressure rating of 1,740 psi and a burst pressure rating that is higher. Overpressure rating indicates the maximum pressure the transmitter can withstand without permanent damage or loss of calibration. It is important not to exceed this limit during operation or testing. For exact burst pressure and other specifications, refer to the product datasheet. 3G Electric provides datasheets for all listed WIKA products.