The MERSEN ATDR Series ATDR17-1/2 is a 17.5 A, 600 V AC time-delay cylindrical fuse with a dual-element design and melamine body. It is non-indicating, measures 13/32 in x 1 1/2 in, and is intended for branch circuit…

SKU 3G-OTH-772757

Also listed as: ATDR1712 · ATDR17 1 2 · ATDR17-1-2

Brand
MERSEN
Item
ATDR17-1/2 Time-Delay Cylindrical Fuse
Part Number
ATDR17-1/2
Category
Time-Delay Cylindrical Fuses
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Compliance & shipping

Hazardous material
Not classified as hazardous
California Prop 65 warning
No warning recorded
Licence required
No licence required
Safety Data Sheet
Not available
Special shipping
Ships under standard freight

Technical Specifications

MERSEN
Manufacturer Part Number
ATDR17-1/2
Series
ATDR
Type
Time-Delay, 17.5 A, Non-Indicating, 13/32 in x 1 1/2 in
AC
600 V
Speed
Time-Delay
UNSPSC
39121604
Element
Dual
Standards
UL/CSA
Catalog Page
172
Body Material
Melamine
Current Rating
17.5 A Current Rating This describes the maximum current these devices can safely handle. Exceeding this current may cause equipment damage or create electrical shock hazards.
Overall Length
1-1/2 in Overall Length
Fuse Body Style
Cylindrical
Fuse Block Style
Rejection
Overall Diameter
13/32 in Overall Diameter
Country of Origin
Mexico (subject to change)
Fuse Applications
Branch Circuit Protection
Visual Indication
Non-Indicating
Fuse Class or Type
CC
Fuse Diameter x Length
13/32 in x 1-1/2 in
Equivalent Brand and Series
Bussmann LP-CC; Littelfuse CCMR; Mersen ATDR
Compatible Fuse Block Series
USCC; USFMCC Compatible Fuse Block Series This describes which series, style, or size of fuse block or holder is compatible with these fuses.
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

MERSEN Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The MERSEN ATDR Series ATDR17-1/2 is a 17.5 A, 600 V AC time-delay cylindrical fuse with a dual-element design and melamine body. It is non-indicating, measures 13/32 in x 1 1/2 in, and is intended for branch circuit protection. This fuse is compatible with the USFMCC fuse block series.

Frequently Asked Questions

What is the MERSEN ATDR17-1/2 fuse used for?

The MERSEN ATDR17-1/2 is a 17.5 A, 600 V AC time-delay cylindrical fuse designed for branch circuit protection. Its dual-element design handles temporary inrush currents, making it suitable for motor and equipment circuits in industrial plants, HVAC systems, and power distribution panels.

What are the specifications of the MERSEN ATDR17-1/2 fuse?

The MERSEN ATDR17-1/2 is a 17.5 A, 600 V AC time-delay fuse with a dual-element design and melamine body. It is non-indicating, measures 13/32 in x 1 1/2 in, and is part of the ATDR series. It is compatible with the USFMCC fuse block series for branch circuit protection.

Where to buy the MERSEN ATDR17-1/2 fuse worldwide?

3G Electric supplies the MERSEN ATDR17-1/2 fuse worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your facility. Contact us for a quote and lead time on this branch circuit protection fuse.

How to select the correct MERSEN ATDR fuse for branch circuit protection?

To select the correct MERSEN ATDR fuse, match the voltage rating (600 V AC) and current rating (17.5 A) to your circuit requirements. Ensure the fuse dimensions (13/32 in x 1 1/2 in) fit your fuse block, such as the USFMCC series. The dual-element design provides time-delay for motor start-ups.

Used in

Common applications for MERSEN
Industrial control panels — Mersen USCC1 and USCC2 UL Class CC fuse blocks for DIN rail mounting and finger-safe branch circuit protection.
Motor starters — Mersen ATQ time-delay fuses and DAR0 R-rated fuses for motor overload and short-circuit protection.
Power supplies and instrumentation — Mersen GGM and GSB fast-acting cylindrical fuses for overcurrent protection in compact electronic circuits.
DC systems — Mersen A30QS very-fast-acting square fuses rated 300 V DC for semiconductor and DC equipment protection.
Medium-voltage distribution — Mersen DAR0 R-rated fuses rated 5.08 kV AC for general-purpose overcurrent protection with visual indication.
Not sure this is the right part? Photo-identify it→

MERSEN Products

3G Electric supplies MERSEN time-delay cylindrical fuses. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

More from MERSEN

View all MERSEN parts →
Time-delay cylindrical fuse from the ATQ Series, rated 8 A and 500 V AC. Midget size with 13/32 in x 1 1/2 in dimensions and non-indicating design. Provides overload and short-circuit protection for circuits that experience temporary inrush currents, such as control transformers and motor starters
MERSEN
Time-delay cylindrical fuse from the ATQ Series, rated 8 A and 500 V AC. Midget size with 13/32 in x 1 1/2 in dimensions and non-indicating design. Provides overload and short-circuit protection for circuits that experience temporary inrush currents, such as control transformers and motor starters
Midget time-delay fuse rated 100 mA at 250 V AC. Measures 13/32 in x 1 1/2 in with indicating feature for visual blown-fuse identification. Provides overcurrent protection in circuits such as control transformers, solenoids, and instrumentation where temporary inrush currents occur
MERSEN
Midget time-delay fuse rated 100 mA at 250 V AC. Measures 13/32 in x 1 1/2 in with indicating feature for visual blown-fuse identification. Provides overcurrent protection in circuits such as control transformers, solenoids, and instrumentation where temporary inrush currents occur
MERSEN GDG Series time-delay cylindrical fuse rated 2.5 A, 250 V AC. Physical dimensions are 5.1 mm x 20.1 mm. Designed for overcurrent protection in industrial equipment such as control panels, motor circuits, and power supplies where tolerance to inrush currents is required
MERSEN
MERSEN GDG Series time-delay cylindrical fuse rated 2.5 A, 250 V AC. Physical dimensions are 5.1 mm x 20.1 mm. Designed for overcurrent protection in industrial equipment such as control panels, motor circuits, and power supplies where tolerance to inrush currents is required
Class RK1 time-delay cylindrical fuse rated 30 A at 250 V AC and 250 V DC. Features indicating function for blown fuse detection. Suitable for overcurrent protection in motor circuits, transformers, and other equipment with inrush currents
MERSEN
Class RK1 time-delay cylindrical fuse rated 30 A at 250 V AC and 250 V DC. Features indicating function for blown fuse detection. Suitable for overcurrent protection in motor circuits, transformers, and other equipment with inrush currents
Time-delay cylindrical fuse rated 5 A and 250 V AC with a non-indicating 5 mm x 20 mm body. Suitable for overcurrent protection in industrial equipment, power supplies, and control panels where delayed response to transient surges is required. Equivalent to S505, 477, and GSF fuse series
MERSEN
Time-delay cylindrical fuse rated 5 A and 250 V AC with a non-indicating 5 mm x 20 mm body. Suitable for overcurrent protection in industrial equipment, power supplies, and control panels where delayed response to transient surges is required. Equivalent to S505, 477, and GSF fuse series
Class RK5 time-delay cylindrical fuse rated 20 A, 250 V AC and 160 V DC. Features visual indication for blown fuse detection. Used for motor and transformer protection in industrial control panels, switchgear, and distribution equipment requiring inrush current tolerance and overload protection
MERSEN
Class RK5 time-delay cylindrical fuse rated 20 A, 250 V AC and 160 V DC. Features visual indication for blown fuse detection. Used for motor and transformer protection in industrial control panels, switchgear, and distribution equipment requiring inrush current tolerance and overload protection
Time-delay cylindrical fuse rated 125 mA at 600 V AC. Dual-element design with melamine body, non-indicating, 13/32 in x 1 1/2 in. Suited for control transformers and solenoids in industrial circuits
MERSEN
Time-delay cylindrical fuse rated 125 mA at 600 V AC. Dual-element design with melamine body, non-indicating, 13/32 in x 1 1/2 in. Suited for control transformers and solenoids in industrial circuits

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first