Allanson 2729-630 Ferromagnetic Transformer for Card Miser, Carlin
The Allanson 2729-630 is a ferromagnetic ignition transformer from the Small Can Series, designed for Carlin 99, 100, 101 and Card Miser burners. It operates on 220V input at 50Hz with a secondary voltage of 10000…
SKU 3G-OTH-03143
Also listed as: 2729630 · 2729 630
Local availability & support — Singapore
- Local office
- 20 Woodlands Link #09-05, Singapore 738733
- Phone
- +65 8878 8355
- Delivery
- Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
- Payment
- Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
- Ships to
- Singapore
Need installation or engineering help?
Ask a question
Product Description
The Allanson 2729-630 is a ferromagnetic ignition transformer from the Small Can Series, designed for Carlin 99, 100, 101 and Card Miser burners. It operates on 220V input at 50Hz with a secondary voltage of 10000 Volts, 23mA current, and features a mid-point ground, end hinge, and spring clip contact for the HV terminal.
Frequently Asked Questions
What is the Allanson 2729-630 ferromagnetic transformer used for?
The Allanson 2729-630 ferromagnetic transformer provides reliable ignition for commercial and industrial oil burners, specifically the Carlin 99, 100, 101, and Card Miser models. It is designed for constant duty and delivers a 10,000 volt secondary output at 23 mA.
What are the specifications of the Allanson 2729-630 transformer?
The Allanson 2729-630 has an input voltage of 220 V at 50 Hz, secondary voltage of 10,000 volts RMS, and secondary short circuit current of 23 mA. It features mid-point grounding, a spring clip HV terminal, and end hinge location. Operating temperature range is -30 to +40 °C.
Where to buy the Allanson 2729-630 transformer in Singapore?
3G Electric supplies the Allanson 2729-630 ferromagnetic transformer to Singapore. We source and deliver this ignition transformer for Carlin and Card Miser burners, handling logistics, customs clearance, and delivery to your facility. Contact us for availability and lead time.
How to install the Allanson 2729-630 transformer on a Carlin burner?
Ensure the transformer is mounted securely using the end hinge and that the spring clip HV terminal makes firm contact with the ignition electrode. Verify the input supply is 220 V at 50 Hz and that the loading air gap is set between 1/8 and 3/16 inches. Follow Allanson's constant-duty guidelines for safe operation.
Used in
Common applications for AllansonAllanson Products
3G Electric supplies Allanson ignition transformers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.