Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Allanson 2744-620 Ferromagnetic Ignition Transformer for Wayne - Ignition Transformers
AllansonIgnition Transformers

Allanson 2744-620 Ferromagnetic Ignition Transformer for Wayne

Allanson’s Double Pole ferromagnetic transformers are designed for constant duty and provide the most reliable ignition source for commercial, residential and industrial oil applications.

SKU 3G-OTH-03283

Also listed as: 2744620 · 2744 620

Brand
Allanson
Item
2744-620 Ferromagnetic Ignition Transformer for Wayne
Category
Ignition Transformers
UNSPSC
39121003 — Instrument transformers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Allanson
Poles
Double
Current
23mA
Can Size
Small Can Series
Grounding
Mid Point Ground
Application
OIL
Burner Type
E
Hv Terminal
Large Spring Contact
Input Voltage
240V
Hinge Location
Side Hinge
Input Frequency
60Hz
Secondary Voltage
10000V
Burner Manufacturer
WAYNE

Datasheet Content

[{"filename":"FerromagneticDP_SpecSheet_21-4141121_04-Sep-2025.pdf","text":"FERROMAGNETIC TRANSFORMERS\n 2721 / 2744 / 2730 / 2714 / 421 / 444 / 911 / 912\n SPECIFICATION GUIDE\n\n\n DOUBLE POLE, MID POINT GROUND MODELS\n\n Allanson’s ferromagnetic transformers are designed for constant duty and provide the most reliable ignition\n source for commercial and/or industrial oil applications.\n\n\n Absolute Maximum Ratings\n Model # 2721, 421* 2744, 444* 911* 2730, 912* 2714\n Rated Operating Input Voltage (V) 120 240 240 120 120\n Operating Input Voltage Range (V) 108-132 216-252 216-252 108-132 108-132\n Input Supply Frequency (Hz) 60 60 50 50 60\n Primary Voltage - Amperes (VA) 250 250 250 250 275\n Secondary Voltage (RMS) 10,000 10,000 10,000 10,000 12,000\n Secondary Short Circuit Current (mA) 23 23 23 23 20\n Storage Temperature (°C) -40 to +80 -40 to +80 -40 to +80 -40 to +80 -40 to +80\n Operating Temperature (°C) -30 to +40 -30 to +40 -30 to +40 -30 to +40 -30 to +40\n Operating Relative Humidity (%) 90 90 90 90 90\n Loading Air Gap (inches) 1/8 - 3/16 1/8 - 3/16 1/8 - 3/16 1/8 - 3/16 1/8 - 3/16\n\n * Service replacement transformers are available in select models.\n\n\n\n\n83 Commerce Valley Drive E., Markham, ON L3T 7T3 181 Cooper Ave., Suite 112, Tonawanda, NY 14150 #21-414\n T: 1.800.661.7251 ● F: 1.416.752.6718 T: 1.631.293.3880 ● F: 1.631.293.3470 1121\n\n\n For more information, please visit us at allanson.com or e-mail us at cservice@allanson.com"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Allanson Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Allanson’s Double Pole ferromagnetic transformers are designed for constant duty and provide the most reliable ignition source for commercial, residential and industrial oil applications.

Frequently Asked Questions

What is the Allanson 2744-620 ignition transformer used for?

The Allanson 2744-620 is a double-pole ferromagnetic ignition transformer designed for constant-duty oil burners. It provides a reliable ignition source for commercial, residential, and industrial oil applications, specifically for Wayne burners.

What are the specifications of the Allanson 2744-620?

The Allanson 2744-620 has a 240 V input at 60 Hz, 10,000 V secondary output, 23 mA secondary short-circuit current, and 250 VA rating. It features a small can size, side hinge, large spring contact HV terminal, and mid-point grounding.

Where to buy the Allanson 2744-620 in Singapore?

You can source the Allanson 2744-620 ignition transformer through 3G Electric in Singapore. We handle logistics, customs clearance, and delivery to your facility, ensuring a smooth procurement process for industrial oil burner components.

How to install the Allanson 2744-620 ignition transformer?

Ensure the transformer is mounted securely with the side hinge aligned. Connect the 240 V input to the primary terminals and the high-voltage lead to the burner electrode. Verify the mid-point ground connection and maintain a 1/8 to 3/16 inch air gap for reliable ignition.

Used in

Common applications for Allanson
Oil burner retrofit maintenance — Allanson CAT 1092 TYPE F transformer replacement in existing Beckett control circuits
Industrial heating-system commissioning — Control transformer installation in multi-stage flame-safeguard burner startup sequences
Plant emergency maintenance — Same-day T92 transformer procurement to restore failed ignition control voltage supply
Burner control-cabinet assembly — Allanson transformer integration in custom control-circuit designs for process-heating applications
Field technician spare-parts kit — Stocking CAT 1092 and T92 variants for mobile maintenance coverage of regional burner installations

Allanson Products

3G Electric supplies Allanson ignition transformers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Allanson 2744-619 Ferromagnetic Ignition Transformer for Wayne
Allanson
Allanson 2744-619 Ferromagnetic Ignition Transformer for Wayne
Allanson 2744-637 Ferromagnetic Ignition Transformer for Wayne
Allanson
Allanson 2744-637 Ferromagnetic Ignition Transformer for Wayne
Allanson 2744-668 Ferromagnetic Ignition Transformer for Wayne
Allanson
Allanson 2744-668 Ferromagnetic Ignition Transformer for Wayne
Allanson 2730-620 Ferromagnetic Ignition Transformer for Wayne
Allanson
Allanson 2730-620 Ferromagnetic Ignition Transformer for Wayne
Allanson 2729-620 Ferromagnetic Ignition Transformer for Wayne
Allanson
Allanson 2729-620 Ferromagnetic Ignition Transformer for Wayne
Allanson 2730-619 Ferromagnetic Ignition Transformer for Wayne
Allanson
Allanson 2730-619 Ferromagnetic Ignition Transformer for Wayne

More from Allanson

View all Allanson parts
Allanson 2744-448 Ferromagnetic Ignition Transformer for Nu Way
Allanson
Allanson 2744-448 Ferromagnetic Ignition Transformer for Nu Way
Allanson 2744-457 Ferromagnetic Ignition Transformer for Acme Weatherall
Allanson
Allanson 2744-457 Ferromagnetic Ignition Transformer for Acme Weatherall
Allanson 2730-448 Ferromagnetic Ignition Transformer for Nu Way
Allanson
Allanson 2730-448 Ferromagnetic Ignition Transformer for Nu Way
Allanson
Allanson
Allanson 2742-662 Ignition Transformer for Gordon Piatt
Allanson
Allanson
Allanson 2742-655-G Ignition Transformer for Power Flame
Allanson
Allanson
Allanson 2742-500 Ignition Transformer
Allanson 2729-452 Ferromagnetic Transformer for Abc, D&lc
Allanson
Allanson 2729-452 Ferromagnetic Transformer for Abc, D&lc
Allanson 2730-637 Ferromagnetic Ignition Transformer for Wayne
Allanson
Allanson 2730-637 Ferromagnetic Ignition Transformer for Wayne