Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Image not available
AllansonIgnition Transformers

Allanson 444-664 Ferromagnetic Service Replacement Transformer for Webster Engineering

The Allanson 444-664 is a ferromagnetic service replacement ignition transformer designed for oil-burner applications, specifically for Webster Engineering burners. It operates on a 240V, 60Hz input and delivers a…

SKU 3G-OTH-03216

Also listed as: 444664 · 444 664

Brand
Allanson
Item
444-664 Ferromagnetic Service Replacement Transformer for Webster Engineering
Category
Ignition Transformers
UNSPSC
39121003 — Instrument transformers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Allanson
Current
23mA
Can Size
Large Can Series
Grounding
Mid Point Ground
Application
OIL
Burner Type
WEBSTER ENGINEERING
Hv Terminal
Thumb Screw
Junction Box
INTERNAL
Input Voltage
240V
Input Frequency
60Hz
Secondary Voltage
10000 Volt
Burner Manufacturer
WEBSTER ENGINEERING

Datasheet Content

[{"filename":"FerromagneticDP_SpecSheet_21-4141121.pdf","text":"FERROMAGNETIC TRANSFORMERS\n 2721 / 2744 / 2730 / 2714 / 421 / 444 / 911 / 912\n SPECIFICATION GUIDE\n\n\n DOUBLE POLE, MID POINT GROUND MODELS\n\n Allanson’s ferromagnetic transformers are designed for constant duty and provide the most reliable ignition\n source for commercial and/or industrial oil applications.\n\n\n Absolute Maximum Ratings\n Model # 2721, 421* 2744, 444* 911* 2730, 912* 2714\n Rated Operating Input Voltage (V) 120 240 240 120 120\n Operating Input Voltage Range (V) 108-132 216-252 216-252 108-132 108-132\n Input Supply Frequency (Hz) 60 60 50 50 60\n Primary Voltage - Amperes (VA) 250 250 250 250 275\n Secondary Voltage (RMS) 10,000 10,000 10,000 10,000 12,000\n Secondary Short Circuit Current (mA) 23 23 23 23 20\n Storage Temperature (°C) -40 to +80 -40 to +80 -40 to +80 -40 to +80 -40 to +80\n Operating Temperature (°C) -30 to +40 -30 to +40 -30 to +40 -30 to +40 -30 to +40\n Operating Relative Humidity (%) 90 90 90 90 90\n Loading Air Gap (inches) 1/8 - 3/16 1/8 - 3/16 1/8 - 3/16 1/8 - 3/16 1/8 - 3/16\n\n * Service replacement transformers are available in select models.\n\n\n\n\n83 Commerce Valley Drive E., Markham, ON L3T 7T3 99 Adams Blvd., Farmingdale, New York 11735 #21-414\n T: 1.800.661.7251 ● F: 1.416.752.6718 T: 1.631.293.3880 ● F: 1.631.293.3470 1121\n\n\n For more information, please visit us at allanson.com or e-mail us at cservice@allanson.com"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Allanson Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Allanson 444-664 is a ferromagnetic service replacement ignition transformer designed for oil-burner applications, specifically for Webster Engineering burners. It operates on a 240V, 60Hz input and delivers a secondary voltage of 10000 Volt with a current rating of 23mA. This Large Can Series unit features internal junction box, mid-point grounding, and a thumb screw high-voltage terminal.

Frequently Asked Questions

What is the Allanson 444-664 ferromagnetic transformer used for?

The Allanson 444-664 is a service replacement ferromagnetic ignition transformer designed for constant-duty commercial and industrial oil burners, specifically Webster Engineering models. It provides a reliable 10,000 V secondary voltage at 23 mA for consistent ignition in oil-fired heating systems.

What are the specifications of the Allanson 444-664 transformer?

The Allanson 444-664 operates at 240 V input, 60 Hz, with a secondary voltage of 10,000 V RMS and 23 mA short-circuit current. It features a large can size, mid-point grounding, thumb-screw HV terminals, and an internal junction box. Operating temperature range is -30 to +40 °C.

Where to buy the Allanson 444-664 transformer in Singapore?

3G Electric supplies the Allanson 444-664 ferromagnetic transformer to customers in Singapore. We source and deliver this Webster Engineering service replacement transformer, handling logistics, customs clearance, and delivery to your facility. Contact us for availability and lead time.

How to install the Allanson 444-664 transformer on a Webster oil burner?

Ensure the transformer is mounted securely with proper clearance for the 1/8 to 3/16 inch air gap. Connect the 240 V input to the internal junction box, verify mid-point grounding, and attach the thumb-screw HV terminals to the ignition electrodes. Follow Allanson's guidelines for safe installation.

Used in

Common applications for Allanson
Oil burner retrofit maintenance — Allanson CAT 1092 TYPE F transformer replacement in existing Beckett control circuits
Industrial heating-system commissioning — Control transformer installation in multi-stage flame-safeguard burner startup sequences
Plant emergency maintenance — Same-day T92 transformer procurement to restore failed ignition control voltage supply
Burner control-cabinet assembly — Allanson transformer integration in custom control-circuit designs for process-heating applications
Field technician spare-parts kit — Stocking CAT 1092 and T92 variants for mobile maintenance coverage of regional burner installations

Allanson Products

3G Electric supplies Allanson ignition transformers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Allanson 421-664 Ferromagnetic Ignition Transformer for Webster Engineering
Allanson
Allanson 421-664 Ferromagnetic Ignition Transformer for Webster Engineering
Allanson 1196-SG Ferromagnetic Ignition Transformer for Webster
Allanson
Allanson 1196-SG Ferromagnetic Ignition Transformer for Webster
Allanson 1112-SG Ferromagnetic Ignition Transformer for Webster
Allanson
Allanson 1112-SG Ferromagnetic Ignition Transformer for Webster
Allanson 1092-SG Ferromagnetic Ignition Transformer for Webster
Allanson
Allanson 1092-SG Ferromagnetic Ignition Transformer for Webster
Allanson 444-331 Ferromagnetic Service Replacement Transformer for Lennox
Allanson
Allanson 444-331 Ferromagnetic Service Replacement Transformer for Lennox
Allanson 444-659 Ferromagnetic Service Replacement Transformer for Industrial Combustion
Allanson
Allanson 444-659 Ferromagnetic Service Replacement Transformer for Industrial Combustion

More from Allanson

View all Allanson parts
Allanson 2744-448 Ferromagnetic Ignition Transformer for Nu Way
Allanson
Allanson 2744-448 Ferromagnetic Ignition Transformer for Nu Way
Allanson 2744-457 Ferromagnetic Ignition Transformer for Acme Weatherall
Allanson
Allanson 2744-457 Ferromagnetic Ignition Transformer for Acme Weatherall
Allanson 2730-448 Ferromagnetic Ignition Transformer for Nu Way
Allanson
Allanson 2730-448 Ferromagnetic Ignition Transformer for Nu Way
Allanson
Allanson
Allanson 2742-662 Ignition Transformer for Gordon Piatt
Allanson
Allanson
Allanson 2742-655-G Ignition Transformer for Power Flame
Allanson
Allanson
Allanson 2742-500 Ignition Transformer
Allanson 2729-452 Ferromagnetic Transformer for Abc, D&lc
Allanson
Allanson 2729-452 Ferromagnetic Transformer for Abc, D&lc
Allanson 2730-637 Ferromagnetic Ignition Transformer for Wayne
Allanson
Allanson 2730-637 Ferromagnetic Ignition Transformer for Wayne