Allanson 911-663 Ferromagnetic Service Replacement Transformer
The Allanson 911-663 is a ferromagnetic service replacement transformer designed for oil applications. It features a large can series with internal junction box, 240V input at 50Hz, 10000 Volt secondary, 23mA…
SKU 3G-OTH-03331
Also listed as: 911663 · 911 663
Local availability & support — Singapore
- Local office
- 20 Woodlands Link #09-05, Singapore 738733
- Phone
- +65 8878 8355
- Delivery
- Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
- Payment
- Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
- Ships to
- Singapore
Need installation or engineering help?
Ask a question
Product Description
The Allanson 911-663 is a ferromagnetic service replacement transformer designed for oil applications. It features a large can series with internal junction box, 240V input at 50Hz, 10000 Volt secondary, 23mA current, and mid-point grounding with thumb screw HV terminals.
Frequently Asked Questions
What is the Allanson 911-663 ferromagnetic transformer used for?
The Allanson 911-663 is a service replacement ferromagnetic transformer designed for constant-duty ignition in commercial and industrial oil-burning applications. It provides a reliable 10,000-volt secondary output at 23 mA for oil burner systems.
What are the specifications of the Allanson 911-663 transformer?
The Allanson 911-663 operates on 240 V input at 50 Hz, with a secondary voltage of 10,000 volts and 23 mA short-circuit current. It features mid-point grounding, a large can size, internal junction box, and thumb-screw HV terminals. Storage temperature range is -40 to +80 °C.
Where to buy the Allanson 911-663 transformer in Singapore?
3G Electric supplies the Allanson 911-663 ferromagnetic service replacement transformer to customers in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this model.
How to install the Allanson 911-663 transformer?
Installation should follow the manufacturer's guidelines: ensure the transformer is mounted securely with the recommended 1/8 to 3/16 inch air gap. Connect the 240 V input to the primary terminals and the 10,000 V secondary to the oil burner ignition system. Always disconnect power before servicing.
Used in
Common applications for AllansonAllanson Products
3G Electric supplies Allanson service replacement transformers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.