Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Image not available
AllansonUV Ballasts

Allanson UVB120WHO-120-240V UV Ballast – Program Start

3G-OTH-03007 UV BALLAST – Program Start

SKU 3G-OTH-03007

Also listed as: UVB120WHO120240V · UVB120WHO 120 240V

Brand
Allanson
Item
UVB120WHO-120-240V UV Ballast – Program Start
Category
UV Ballasts
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Allanson
Size
5.3″x1.8″x1.10″
Lamps
1 to 2
Weight
0.8 lb
Lamp mA
800
Lamp Type
High-output
Input Lamps
1 to 2
Lamp Length
24″ to 42″
Potted Case
Yes
Input Voltage
120V-240V
Input Wattage
120

Datasheet Content

[{"filename":"UVB120WHO-120-240V_WEB.pdf","text":"Specifications Guide\n UVB Ballasts\nUVB120WHO-120-240V\n Current\n Lamp Type /Catalog # Manufacturer # of Lamps Power (W)\n (A)\n CHS-120WH Light Progress 1 120 800\n CHS-90WH Light Progress 1 90 800\n CHS-60WH Light Progress 2 60 800\n GTD40\" VO Steril-Aire 1 110 800\n GTS36\" VO Steril-Aire 1 85 800\n GTS24\" VO Steril-Aire 2 60 800\n TUV PL-L95W/HO Philips 1 95 800\n TUV PL-L60W/HO Philips 2 60 800\n\n\nBallast Specifications\nBallast type: Program Start (PS) Operating frequency: > 30kHz\nNumber of lamps: 1-2 Lamp current crest factor: 1.7 or less\nNormal input voltage: 120-240V, +/-10%, 50/60 Hz Efficiency: > 90%\nInput current: 1.05A(120V)/0.53A(240V) Ambient temperature: 0-40ºC\nInput power: 125W @ full load Case maximum temperature: 75ºC\nPower factor: > 95% Striking/Ignition voltage: 1500 volt\nOutput current: 800 mA Filament preheat time: 1.5-2.0 seconds\nApprovals: UL Listed, Class “P”, Ballast shut down/Protection: EOL/OC\n Indoor, Type 1 EMI requirements: Meet FCC Part 18\n Weight: 0.80 lbs\n\nWiring Diagram and Dimensions\n Dimensions: 5.3\" (L) x 1.8\" (W) x 1.10\" (H)\n\n\n\n\n 83 Commerce Valley Drive East, Markham, ON L3T 7T3 Canada\n www.allanson.com | cservice@allanson.com | T: 1.800.668.9162 | F: 416.752.6717"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Allanson Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

3G-OTH-03007 UV BALLAST – Program Start

Frequently Asked Questions

What is the Allanson 3G-OTH-03007 UV ballast used for?

The Allanson 3G-OTH-03007 is a program-start UV ballast designed to power high-output UV lamps in germicidal applications such as air and surface disinfection. It supports 1 to 2 lamps with 800 mA output current and is compatible with lamps from Light Progress, Steril-Aire, and Philips.

What are the specifications of the Allanson 3G-OTH-03007?

The Allanson 3G-OTH-03007 operates at 120-240V input, 50/60 Hz, with 800 mA output current. It powers 1 to 2 high-output lamps, has a power factor above 95%, efficiency above 90%, and dimensions of 5.3" x 1.8" x 1.10". It is UL Listed and meets FCC Part 18 EMI requirements.

Where to buy the Allanson 3G-OTH-03007 in Singapore?

3G Electric supplies the Allanson 3G-OTH-03007 UV ballast to customers in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this program-start ballast for germicidal UV systems.

How to install the Allanson 3G-OTH-03007 UV ballast?

Install the Allanson 3G-OTH-03007 by wiring according to the diagram on the ballast label, ensuring input voltage matches 120-240V. Mount in a dry, indoor location with ambient temperature 0-40°C. The ballast provides filament preheat of 1.5-2.0 seconds and includes EOL/OC protection.

Used in

Common applications for Allanson
Oil burner retrofit maintenance — Allanson CAT 1092 TYPE F transformer replacement in existing Beckett control circuits
Industrial heating-system commissioning — Control transformer installation in multi-stage flame-safeguard burner startup sequences
Plant emergency maintenance — Same-day T92 transformer procurement to restore failed ignition control voltage supply
Burner control-cabinet assembly — Allanson transformer integration in custom control-circuit designs for process-heating applications
Field technician spare-parts kit — Stocking CAT 1092 and T92 variants for mobile maintenance coverage of regional burner installations

Allanson Products

3G Electric supplies Allanson uv ballasts. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Allanson
Allanson
Allanson UVB248T6-2100-48VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB264T6-1400-230V UV Ballast – Instant Start
Allanson
Allanson
Allanson UVB248T5-425-MV UV Ballast – Instant Start
Allanson
Allanson
Allanson UVB264T5-800-MV UV Ballast – Instant Start

More from Allanson

View all Allanson parts
Allanson
Allanson
Allanson UVB50W-24V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB100WHO-120-240V-LP UV Ballast – Program Start with Dimming
Allanson
Allanson
Allanson UVB264T5-425-MV-P UV Ballast – Instant Start
Allanson
Allanson
Allanson UVB424T6-1000-120-240V-SL UV Ballast – Program Start
Allanson
Allanson
Allanson UVB160WHO-120-277V-SS UV Ballasts – Program Start
Allanson
Allanson
Allanson UVB80W-800-24VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB50W-800-12VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB164T6-2100-MV-PDPH UV Ballasts – Program Start