AllansonUV Ballasts

Allanson UVB120WHO-120-240V-ID UV Ballast – Program Start

3G-OTH-03008 UV BALLAST – Program Start

SKU 3G-OTH-03008

Also listed as: UVB120WHO120240VID · UVB120WHO 120 240V ID

Brand
Allanson
Item
UVB120WHO-120-240V-ID UV Ballast – Program Start
Category
UV Ballasts
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Allanson
Size
5.0″x3.0″x1.35″
Lamps
1
Weight
1.1 lb
Lamp mA
800
Lamp Type
High-output
Input Lamps
1 to 2
Lamp Length
24″ to 42″
Potted Case
Yes
Input Voltage
120V-240V
Input Wattage
120

Datasheet Content

[{"filename":"12.UVB120WHO-120-240V-ID_WEB_07.22.pdf","text":"Specifications Guide\n UV Ballasts\nUVB120WHO-120-240V-ID\n Lamp Type /Catalog # Manufacturer # of Lamps Power (W) Current (mA)\n\n GPH1148T5HO Light Source 1 to 2 120 800\n GPH1067T5HO Light Source 1 to 2 110 800\n TUV PL-L 95W/4P HO Philps 1 to 2 95 800\n TUV PL-L 60W/4P HO Philps 1 to 2 60 800\n TUV 36T5 HO Philps 1 to 2 75 800\n\n\nBallast Specifications\nBallast type: Program Start (PS) Power Factor: > 95%\nNumber of lamps: 1 Output Current: 800mA\nNormal input voltage: 120-240V, +/-10%, 50-60Hz Efficiency: > 90%\nInput current: 1.05A(120V)/0.53A(240V) Lamp Current Crest Factor: 1.7 or less\nInput power: 120W @ full load Striking/Ignition voltage: 1500 volt\nOperating frequency: > 30kHz Filament preheat time: 1.5-2.0 seconds\nEMI requirements: Meet FCC Part 18 Ballast shut down/protection: EOL/OC\nApprovals: UL/cUL Listed, Class “P”, Ambient temperature: 0-40ºC\n Indoor, Type 1, CE Case maximum temperature: 75ºC\n Sound rating: “A”\n Weight: 1.10 lbs\n\n\nWiring Diagram and Dimensions\n Leads available for external LEDs in both input\n side (Power on), and output side (Lamp on).\n\n\n\n\n 1.32”\n\n\n\n\n 5.0”\n 3.0”\n\n\n\n\n 83 Commerce Valley Drive East, Markham, ON L3T 7T3\n www.allanson.com | cservice@allanson.com | T: 1.800.661.7251 | F: 416.752.6717"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Allanson Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

3G-OTH-03008 UV BALLAST – Program Start

Frequently Asked Questions

What is the Allanson 3G-OTH-03008 UV ballast used for?

The Allanson 3G-OTH-03008 is a program-start UV ballast designed to power high-output UV lamps in water treatment, air purification, and industrial disinfection systems. It supports 1 to 2 lamps, including GPH1148T5HO and TUV PL-L models, with 800 mA output current and 120W input power.

What are the specifications of the Allanson 3G-OTH-03008?

The Allanson 3G-OTH-03008 operates at 120-240V input, 50-60 Hz, with 120W input power and 800 mA output current. It measures 5.0"x3.0"x1.35", weighs 1.1 lb, and features program start, >95% power factor, UL/cUL listing, and a potted case for durability.

Where to buy the Allanson 3G-OTH-03008 in Singapore?

3G Electric supplies the Allanson 3G-OTH-03008 UV ballast to Singapore. We source and deliver this program-start ballast, handling logistics, customs clearance, and local delivery. Contact us for pricing and lead time on orders.

How to install the Allanson 3G-OTH-03008 UV ballast?

Install the Allanson 3G-OTH-03008 by connecting input leads to a 120-240V supply and output leads to compatible high-output UV lamps. Ensure ambient temperature is 0-40°C and case temperature stays below 75°C. Follow wiring diagrams for external LEDs and verify lamp compatibility from the datasheet.

Used in

Common applications for Allanson
Oil burner retrofit maintenance — Allanson CAT 1092 TYPE F transformer replacement in existing Beckett control circuits
Industrial heating-system commissioning — Control transformer installation in multi-stage flame-safeguard burner startup sequences
Plant emergency maintenance — Same-day T92 transformer procurement to restore failed ignition control voltage supply
Burner control-cabinet assembly — Allanson transformer integration in custom control-circuit designs for process-heating applications
Field technician spare-parts kit — Stocking CAT 1092 and T92 variants for mobile maintenance coverage of regional burner installations

Allanson Products

3G Electric supplies Allanson uv ballasts. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Allanson
Allanson
Allanson UVB248T6-2100-48VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB264T6-1400-230V UV Ballast – Instant Start
Allanson
Allanson
Allanson UVB248T5-425-MV UV Ballast – Instant Start
Allanson
Allanson
Allanson UVB264T5-800-MV UV Ballast – Instant Start

More from Allanson

View all Allanson parts
Allanson
Allanson
Allanson UVB50W-24V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB100WHO-120-240V-LP UV Ballast – Program Start with Dimming
Allanson
Allanson
Allanson UVB264T5-425-MV-P UV Ballast – Instant Start
Allanson
Allanson
Allanson UVB424T6-1000-120-240V-SL UV Ballast – Program Start
Allanson
Allanson
Allanson UVB160WHO-120-277V-SS UV Ballasts – Program Start
Allanson
Allanson
Allanson UVB80W-800-24VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB50W-800-12VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB164T6-2100-MV-PDPH UV Ballasts – Program Start