Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Image not available
AllansonUV Ballasts

Allanson UVB60W-425-24VDC UV Ballast – Program Start

3G-OTH-03048 UV BALLAST – Program Start

SKU 3G-OTH-03048

Also listed as: UVB60W42524VDC · UVB60W 425 24VDC

Brand
Allanson
Item
UVB60W-425-24VDC UV Ballast – Program Start
Category
UV Ballasts
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Allanson
Size
8.5″x2.2″x1.75″
Lamps
1
Weight
2.55 lb
Lamp mA
425
Lamp Type
Standard
Input Lamps
1
Lamp Length
24″ to 48″
Potted Case
Yes
Input Voltage
24V
Input Wattage
60

Datasheet Content

[{"filename":"UVB60W-425-24VDC_WEB.pdf","text":"Specifications Guide\n UV Ballasts\nUVB60W-425-24VDC\n Lamp Type /Catalog # Manufacturer # of Lamps Power (W) Current (mA)\n\n GPH254T5L/4P Light Source 1 14 425\n GPH436T5L/4P Light Source 1 21 425\n GPH843T5L/4P Light Source 1 41 425\n GPH1148T5L/4P Light Source 1 55 425\n\n\n\nBallast Specifications\nBallast type: Program Start (PS) Efficiency: > 90%\nNumber of lamps: 1 Ballast shut down/protection: EOL/OC\nNormal input voltage: 24VDC, +/-10% Ambient temperature: 0-40ºC\nInput current: 2.6A Case maximum temperature: 75ºC\nInput power: 60W @ full load Sound rating: “A”\nOperating frequency: > 35kHz Weight: 2.55 lbs\nApprovals: UL/cUL Listed, Class “P”\n\n\n\n\nWiring Diagram and Dimensions\n Dimensions: 9.47\" (L) x 2.29\" (W) x 1.67\" (H)\n\n\n\n\n 83 Commerce Valley Drive East, Markham, ON L3T 7T3 Canada\n www.allanson.com | cservice@allanson.com | T: 1.800.668.9162 | F: 416.752.6717"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Allanson Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

3G-OTH-03048 UV BALLAST – Program Start

Frequently Asked Questions

What is the Allanson 3G-OTH-03048 UV ballast used for?

The Allanson 3G-OTH-03048 is a program-start UV ballast designed to power single standard UV lamps, such as GPH254T5L/4P, GPH436T5L/4P, GPH843T5L/4P, and GPH1148T5L/4P. It is commonly used in water treatment, air purification, and industrial UV curing systems where reliable lamp ignition and long lamp life are required.

What are the specifications of the Allanson 3G-OTH-03048?

The Allanson 3G-OTH-03048 operates at 24 VDC input voltage, draws 2.6 A, and delivers 60 W input power. It supports one lamp at 425 mA, with an operating frequency above 35 kHz, efficiency over 90%, and approvals including UL/cUL Listed, Class P. Dimensions are 9.47" x 2.29" x 1.67" and weight is 2.55 lb.

Where to buy the Allanson 3G-OTH-03048 in Singapore?

3G Electric supplies the Allanson 3G-OTH-03048 UV ballast to customers in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact our team for a quote and lead time on this program-start ballast. We source genuine Allanson components for industrial applications.

How to install the Allanson 3G-OTH-03048 ballast?

Install the Allanson 3G-OTH-03048 by connecting the 24 VDC input to the correct polarity terminals per the wiring diagram. Mount the ballast in a dry, ventilated area with ambient temperature between 0-40 °C. Ensure the case temperature does not exceed 75 °C. Use only with compatible standard UV lamps listed in the datasheet.

Used in

Common applications for Allanson
Oil burner retrofit maintenance — Allanson CAT 1092 TYPE F transformer replacement in existing Beckett control circuits
Industrial heating-system commissioning — Control transformer installation in multi-stage flame-safeguard burner startup sequences
Plant emergency maintenance — Same-day T92 transformer procurement to restore failed ignition control voltage supply
Burner control-cabinet assembly — Allanson transformer integration in custom control-circuit designs for process-heating applications
Field technician spare-parts kit — Stocking CAT 1092 and T92 variants for mobile maintenance coverage of regional burner installations

Allanson Products

3G Electric supplies Allanson uv ballasts. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Allanson
Allanson
Allanson UVB248T6-2100-48VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB248T5-425-MV UV Ballast – Instant Start
Allanson
Allanson
Allanson UVB264T6-1400-230V UV Ballast – Instant Start
Allanson
Allanson
Allanson UVB264T5-800-MV UV Ballast – Instant Start

More from Allanson

View all Allanson parts
Allanson
Allanson
Allanson UVB50W-24V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB100WHO-120-240V-LP UV Ballast – Program Start with Dimming
Allanson
Allanson
Allanson UVB264T5-425-MV-P UV Ballast – Instant Start
Allanson
Allanson
Allanson UVB424T6-1000-120-240V-SL UV Ballast – Program Start
Allanson
Allanson
Allanson UVB160WHO-120-277V-SS UV Ballasts – Program Start
Allanson
Allanson
Allanson UVB80W-800-24VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB50W-800-12VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB164T6-2100-MV-PDPH UV Ballasts – Program Start