ASHCROFT Pressure Transmitter: -15 psi to 15 psi, 1 to 5V DC, Cable & Wire Leads
The ASHCROFT A2X Explosion-Proof-Rated Transmitter measures compound pressure from -15 psi to 15 psi with ±0.50% of Full Scale accuracy and a 1 to 5V DC output. It features a stainless steel housing, NPT process…
SKU 3G-OTH-175487
Need installation or engineering help?
Ask a question
Product Description
The ASHCROFT A2X Explosion-Proof-Rated Transmitter measures compound pressure from -15 psi to 15 psi with ±0.50% of Full Scale accuracy and a 1 to 5V DC output. It features a stainless steel housing, NPT process connection, and IP65/NEMA 4X ratings, with overpressure of 1.5x Range and burst pressure of 2x Range. This unit is rated Class II, Div 1 and 2, Group E, F, G, includes a NIST-Traceable Calibration Certificate, and is not specified as intrinsically safe.
Frequently Asked Questions
What is the ASHCROFT A2X pressure transmitter used for?
The ASHCROFT A2X explosion-proof-rated transmitter measures compound pressure from -15 psi to 15 psi in hazardous industrial environments. It is suitable for Class II, Div 1 and 2, Group E, F, G locations, such as grain elevators, chemical plants, and oil refineries, where flammable dust or gases may be present.
What are the specifications of the ASHCROFT A2X pressure transmitter?
The ASHCROFT A2X transmitter has a pressure range of -15 psi to 15 psi, output of 1 to 5V DC, accuracy of ±0.50% of Full Scale, stainless steel housing, NPT process connection, IP65 and NEMA 4X ratings, overpressure of 1.5x Range, and burst pressure of 2x Range. It includes a NIST-Traceable Calibration Certificate.
Where to buy the ASHCROFT A2X pressure transmitter worldwide?
3G Electric supplies the ASHCROFT A2X pressure transmitter worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time on this explosion-proof-rated transmitter with NPT connection and 1 to 5V DC output.
How to install the ASHCROFT A2X explosion-proof pressure transmitter?
Install the ASHCROFT A2X transmitter using the NPT process connection with appropriate thread sealant. Ensure the conduit connection is properly sealed to maintain IP65 and NEMA 4X ratings. Follow standard hazardous-location wiring practices for Class II, Div 1 and 2, Group E, F, G areas. Always consult the manufacturer's manual for torque and wiring details.
Used in
Common applications for ASHCROFTASHCROFT Products
3G Electric supplies ASHCROFT explosion-proof with conduit connection & wire leads. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.