Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

ASHCROFT Pressure Transmitter: -15 psi to 15 psi, 1 to 5V DC, Cable & Wire Leads - Explosion-Proof with Conduit Connection & Wire Leads
ASHCROFTExplosion-Proof with Conduit Connection & Wire Leads

ASHCROFT Pressure Transmitter: -15 psi to 15 psi, 1 to 5V DC, Cable & Wire Leads

The ASHCROFT A2X Explosion-Proof-Rated Transmitter measures compound pressure from -15 psi to 15 psi with ±0.50% of Full Scale accuracy and a 1 to 5V DC output. It features a stainless steel housing, NPT process…

SKU 3G-OTH-175487

Brand
ASHCROFT
Item
Pressure Transmitter: -15 psi to 15 psi, 1 to 5V DC, Cable & Wire Leads
Category
Explosion-Proof with Conduit Connection & Wire Leads
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

ASHCROFT
Manufacturer Part Number
A2XBM0215C215#G&VAC
Series
A2X
Type
Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9
DC
1 to 5V
Output
1 to 5V DC
Accuracy
±0.50% of Full Scale
IP Rating
IP65
NEMA Rating
4X
Overpressure
1.5x Range
Product Type
Explosion-Proof-Rated Transmitter
Safety Rating
Class II, Div 1 and 2, Group E, F, G
Burst Pressure
2x Range
Pressure Range
-15 psi to 15 psi
Housing Material
Stainless Steel
Intrinsically Safe
Not Specified Intrinsically Safe
Pressure Type Measured
Compound
Process Connection Type
NPT
NIST Traceable Certificate
NIST-Traceable Calibration Certificate Included
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

ASHCROFT Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The ASHCROFT A2X Explosion-Proof-Rated Transmitter measures compound pressure from -15 psi to 15 psi with ±0.50% of Full Scale accuracy and a 1 to 5V DC output. It features a stainless steel housing, NPT process connection, and IP65/NEMA 4X ratings, with overpressure of 1.5x Range and burst pressure of 2x Range. This unit is rated Class II, Div 1 and 2, Group E, F, G, includes a NIST-Traceable Calibration Certificate, and is not specified as intrinsically safe.

Frequently Asked Questions

What is the ASHCROFT A2X pressure transmitter used for?

The ASHCROFT A2X explosion-proof-rated transmitter measures compound pressure from -15 psi to 15 psi in hazardous industrial environments. It is suitable for Class II, Div 1 and 2, Group E, F, G locations, such as grain elevators, chemical plants, and oil refineries, where flammable dust or gases may be present.

What are the specifications of the ASHCROFT A2X pressure transmitter?

The ASHCROFT A2X transmitter has a pressure range of -15 psi to 15 psi, output of 1 to 5V DC, accuracy of ±0.50% of Full Scale, stainless steel housing, NPT process connection, IP65 and NEMA 4X ratings, overpressure of 1.5x Range, and burst pressure of 2x Range. It includes a NIST-Traceable Calibration Certificate.

Where to buy the ASHCROFT A2X pressure transmitter worldwide?

3G Electric supplies the ASHCROFT A2X pressure transmitter worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time on this explosion-proof-rated transmitter with NPT connection and 1 to 5V DC output.

How to install the ASHCROFT A2X explosion-proof pressure transmitter?

Install the ASHCROFT A2X transmitter using the NPT process connection with appropriate thread sealant. Ensure the conduit connection is properly sealed to maintain IP65 and NEMA 4X ratings. Follow standard hazardous-location wiring practices for Class II, Div 1 and 2, Group E, F, G areas. Always consult the manufacturer's manual for torque and wiring details.

Used in

Common applications for ASHCROFT
Process control in chemical plants — ASHCROFT G2 series pressure transmitters with 4-20 mA output
Sanitary monitoring in food processing — ASHCROFT sanitary pressure transmitters with stainless steel fittings
Temperature measurement in oil and gas — ASHCROFT flanged thermowells rated to 1,000°F
Hydraulic system pressure monitoring — ASHCROFT G2 series transmitters with 1-5 V DC output
Hazardous location pressure sensing — ASHCROFT A2X explosion-proof transmitters with conduit connection
Steam system temperature protection — ASHCROFT threaded thermowells rated to 7,000 psi

ASHCROFT Products

3G Electric supplies ASHCROFT explosion-proof with conduit connection & wire leads. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Similar products

Matched by specification & description
Pressure Transmitter: -15 psi to 15 psi, 1 to 5V DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBM0415C215#G&VAC). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 4X; Output: 1 to 5V DC; Overpressure: 1.5x Range.
ASHCROFT
Pressure Transmitter: -15 psi to 15 psi, 1 to 5V DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBM0415C215#G&VAC). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 4X; Output: 1 to 5V DC; Overpressure: 1.5x Range.
Pressure Transmitter: 0 psi to 15 psi, 1 to 5V DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBM0215C215#G). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 9; Output: 1 to 5V DC; Overpressure: 1.5x Range.
ASHCROFT
Pressure Transmitter: 0 psi to 15 psi, 1 to 5V DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBM0215C215#G). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 9; Output: 1 to 5V DC; Overpressure: 1.5x Range.
Pressure Transmitter: 0 psi to 60 psi, 1 to 5V DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBM0215C260#G). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 7; Output: 1 to 5V DC; Overpressure: 1.5x Range.
ASHCROFT
Pressure Transmitter: 0 psi to 60 psi, 1 to 5V DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBM0215C260#G). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 7; Output: 1 to 5V DC; Overpressure: 1.5x Range.
Pressure Transmitter: 0 psi to 5 psi, 1 to 5V DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBM0215C25#G). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 4X; Output: 1 to 5V DC; Overpressure: 1.5x Range.
ASHCROFT
Pressure Transmitter: 0 psi to 5 psi, 1 to 5V DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBM0215C25#G). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 4X; Output: 1 to 5V DC; Overpressure: 1.5x Range.
Pressure Transmitter: 0 psi to 100 psi, 1 to 5V DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBM0215C2100#G). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 4X; Output: 1 to 5V DC; Overpressure: 1.5x Range.
ASHCROFT
Pressure Transmitter: 0 psi to 100 psi, 1 to 5V DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBM0215C2100#G). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 4X; Output: 1 to 5V DC; Overpressure: 1.5x Range.
Pressure Transmitter: 0 psi to 30 psi, 1 to 5V DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBM0215C230#G). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 7; Output: 1 to 5V DC; Overpressure: 1.5x Range.
ASHCROFT
Pressure Transmitter: 0 psi to 30 psi, 1 to 5V DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBM0215C230#G). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 7; Output: 1 to 5V DC; Overpressure: 1.5x Range.

More from ASHCROFT

View all ASHCROFT parts
Pressure Transmitter, 5,000 psi (MPN E2FA5NF0242CFX03F5000#). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP66; Electrical Connection: 1/2 in NPT Conduit with Cable; Series: E2F; NEMA Rating: 4X; Output: 4 to 20mA.
ASHCROFT
Pressure Transmitter, 5,000 psi (MPN E2FA5NF0242CFX03F5000#). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP66; Electrical Connection: 1/2 in NPT Conduit with Cable; Series: E2F; NEMA Rating: 4X; Output: 4 to 20mA.
Pressure Transmitter: 0 psi to 200 psi, 4 to 20mA DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBF0442C2200#G). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 7; Output: 4 to 20mA DC; Overpressure: 1.5x Range.
ASHCROFT
Pressure Transmitter: 0 psi to 200 psi, 4 to 20mA DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBF0442C2200#G). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 7; Output: 4 to 20mA DC; Overpressure: 1.5x Range.
Pressure Transmitter, 3,000 psi (MPN E2FA5NM0442CFX03F3000#). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP66; Electrical Connection: 1/2 in NPT Conduit with Cable; Series: E2F; NEMA Rating: 4X; Output: 4 to 20mA.
ASHCROFT
Pressure Transmitter, 3,000 psi (MPN E2FA5NM0442CFX03F3000#). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP66; Electrical Connection: 1/2 in NPT Conduit with Cable; Series: E2F; NEMA Rating: 4X; Output: 4 to 20mA.
Pressure Transmitter: 0 psi to 60 psi, 1 to 5V DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBF0215C260#G). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 7; Output: 1 to 5V DC; Overpressure: 1.5x Range.
ASHCROFT
Pressure Transmitter: 0 psi to 60 psi, 1 to 5V DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBF0215C260#G). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 7; Output: 1 to 5V DC; Overpressure: 1.5x Range.
Pressure Transmitter, 15 psi (MPN E2FC5NM0215CFX03FV&15#). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP66; Electrical Connection: 1/2 in NPT Conduit with Cable; Series: E2F; NEMA Rating: 4X; Output: 1 to 5V DC.
ASHCROFT
Pressure Transmitter, 15 psi (MPN E2FC5NM0215CFX03FV&15#). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP66; Electrical Connection: 1/2 in NPT Conduit with Cable; Series: E2F; NEMA Rating: 4X; Output: 1 to 5V DC.
Pressure Transmitter, 1,000 psi (MPN E2FA5NF0242CFX03F1000#). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP66; Electrical Connection: 1/2 in NPT Conduit with Cable; Series: E2F; NEMA Rating: 4X; Output: 4 to 20mA.
ASHCROFT
Pressure Transmitter, 1,000 psi (MPN E2FA5NF0242CFX03F1000#). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP66; Electrical Connection: 1/2 in NPT Conduit with Cable; Series: E2F; NEMA Rating: 4X; Output: 4 to 20mA.
ASHCROFT
ASHCROFT
Pressure Transmitter, 15 psi (MPN E2FC5NM0242CFX03F15#). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP66; Electrical Connection: 1/2 in NPT Conduit with Cable; Series: E2F; NEMA Rating: 4X; Output: 4 to 20mA.
Pressure Transmitter, 60 psi (MPN E2FA5NF0242CFX03F60#). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP66; Electrical Connection: 1/2 in NPT Conduit with Cable; Series: E2F; NEMA Rating: 4X; Output: 4 to 20mA.
ASHCROFT
Pressure Transmitter, 60 psi (MPN E2FA5NF0242CFX03F60#). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP66; Electrical Connection: 1/2 in NPT Conduit with Cable; Series: E2F; NEMA Rating: 4X; Output: 4 to 20mA.