The Bacharach Opacity Meter Kit (3G-CBM-00249) is a gas detection instrument for measuring smoke density and particulate opacity in exhaust streams. Certified to TUV approval and compliant with DIN 51402, the kit…

SKU 3G-CBM-00249

Also listed as: BAC 05010 · BAC-05010

Brand
Bacharach
Item
Opacity meter kit
Category
Gas Detection
UNSPSC
41113117 — Single gas monitors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Bacharach
product code
BAC05010
certification
TUV approved
standard compliance
DIN 51402
sampling pump cycles
10 complete strokes
required measurements
3
piston stroke duration
3 seconds
burner minimum warm up time
5 minutes

Datasheet Content

3G-CBM-00249 Pompe Opacimètre Mode d'emploi .. Agrée TUV 1. Le brûleur doit fonctionner au minimum 5 minutes avant tote mesure .. 2. Placer le filtre en papier dans la fente prévue à cet effet dans la tête de sonde. Garder la posi- tion en tournant la roue crantée sur la droite. 3. Pour effectuer des prélèvements, placer l'extrémité de la sonde dans le flux central des gaz de combustion. 4. Prélever les gas par 10 pompages (aller-retour) complets du piston, (chaque aile devan durer 3 sec., selon la DIN 51402). 5. Libérer le papier filtre en tournant la roue crantée vers la gauche - un point noir est apparu sur le filtre. 6. 3 mesures sont nécessaires. La moyenne arithmétique est l'indice de noircissement (voir 4.2).

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Bacharach Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Bacharach Opacity Meter Kit (3G-CBM-00249) is a gas detection instrument for measuring smoke density and particulate opacity in exhaust streams. Certified to TUV approval and compliant with DIN 51402, the kit operates with a 10-stroke sampling pump cycle, requires 3 measurements per test, and features a 3-second piston stroke duration. Allow 5 minutes minimum burner warm-up time before operation. 3G Electric sources and delivers this equipment to Singapore and Southeast Asia facilities.

Frequently Asked Questions

What is the Bacharach Opacity Meter Kit used for?

The Bacharach Opacity Meter Kit (3G-CBM-00249) is a gas detection instrument used to measure smoke density and particulate opacity in exhaust streams. It is commonly applied in industrial combustion and boiler systems to assess emission quality and ensure compliance with regulatory standards.

What are the specifications of the Bacharach Opacity Meter Kit?

The Bacharach Opacity Meter Kit (3G-CBM-00249) is TUV approved and complies with DIN 51402. It requires 10 complete sampling pump cycles per test, with each piston stroke lasting 3 seconds. Three measurements are needed per test, and a minimum 5-minute burner warm-up time is required before operation.

Where to buy the Bacharach Opacity Meter Kit in Singapore?

3G Electric sources and delivers the Bacharach Opacity Meter Kit (3G-CBM-00249) to facilities in Singapore and Southeast Asia. We handle logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this TUV-approved gas detection instrument.

How to use the Bacharach Opacity Meter Kit correctly?

To use the Bacharach Opacity Meter Kit, first allow the burner to warm up for at least 5 minutes. Insert a paper filter into the probe head, then take 10 complete piston strokes (each lasting 3 seconds) from the exhaust stream. Repeat for a total of 3 measurements and calculate the arithmetic mean for the blackening index.

Used in

Common applications for Bacharach
Oil burner smoke testing—Bacharach Comparison Scale (BAC10018) for direct smoke number measurement during commissioning and maintenance.
Emissions opacity verification—Bacharach Opacity Meter Kit (BAC05010) for DIN 51402 compliance testing on industrial burner stacks.
Combustion gas analysis—Bacharach measurement liquids and reagents (BAC10068) for CO₂ and other gas quantification in field laboratories.
HVAC service diagnostics—Bacharach portable instruments for routine burner performance and air quality checks on heating systems.

Bacharach Products

3G Electric supplies Bacharach gas detection. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Portable combustible gas detector for methane with a detection range of 20 to 500 ppm. Features sound alert and includes a soft carrying case. Suitable for detecting gas leaks in industrial environments
Bacharach
Portable combustible gas detector for methane with a detection range of 20 to 500 ppm. Features sound alert and includes a soft carrying case. Suitable for detecting gas leaks in industrial environments
1 liter bottle test GN
DTekGaz
1 liter bottle test GN
1 liter bottle test CO98 PPM
DTekGaz
1 liter bottle test CO98 PPM
DTekGaz
DTekGaz
Portable CO2 detector
The Bacharach H-10 Pro is a heated diode sensor refrigerant leak detector with a sensitivity of 0.006 oz/yr. It is A2L compatible and operates on 100 to 240V AC or 12V DC. Used for locating refrigerant leaks in HVAC and refrigeration systems
Bacharach
The Bacharach H-10 Pro is a heated diode sensor refrigerant leak detector with a sensitivity of 0.006 oz/yr. It is A2L compatible and operates on 100 to 240V AC or 12V DC. Used for locating refrigerant leaks in HVAC and refrigeration systems
Full-size combustible gas detector with refrigerant and combustible gas sensors. Provides a light alert when methane is detected at 50 ppm. Suitable for locating gas leaks in HVAC and industrial environments
Bacharach
Full-size combustible gas detector with refrigerant and combustible gas sensors. Provides a light alert when methane is detected at 50 ppm. Suitable for locating gas leaks in HVAC and industrial environments

More from Bacharach

View all Bacharach parts
Bacharach
Bacharach
Cell QRB4B-B050B70B
Bacharach
Bacharach
CO2 measurement liquid
Comparison scale
Bacharach
Comparison scale